Cargando…

Performance of the CMS Level-1 Trigger during Run 2

The CMS Level-1 (L1) Trigger system was upgraded in 2016 in order to cope with the threefold increase in peak luminosity of Run 2 compared to Run 1. The upgraded trigger features advanced clustering, calibration, and particle identification techniques. More sophisticated algorithms, for example invo...

Descripción completa

Detalles Bibliográficos
Autor principal: Kwon, Hyejin
Lenguaje:eng
Publicado: 2020
Materias:
Acceso en línea:http://cds.cern.ch/record/2792563
_version_ 1780972367278768128
author Kwon, Hyejin
author_facet Kwon, Hyejin
author_sort Kwon, Hyejin
collection CERN
description The CMS Level-1 (L1) Trigger system was upgraded in 2016 in order to cope with the threefold increase in peak luminosity of Run 2 compared to Run 1. The upgraded trigger features advanced clustering, calibration, and particle identification techniques. More sophisticated algorithms, for example involving the invariant mass of pairs of L1 candidates, were also implemented. The upgrades reduced the trigger rate from background processes and increased the efficiency for a variety of physics signals. This poster highlights a number of improvements that the upgraded L1 Trigger provided during the Run 2 program at CMS.
id cern-2792563
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2020
record_format invenio
spelling cern-27925632021-12-10T19:48:16Zhttp://cds.cern.ch/record/2792563engKwon, HyejinPerformance of the CMS Level-1 Trigger during Run 2Detectors and Experimental TechniquesThe CMS Level-1 (L1) Trigger system was upgraded in 2016 in order to cope with the threefold increase in peak luminosity of Run 2 compared to Run 1. The upgraded trigger features advanced clustering, calibration, and particle identification techniques. More sophisticated algorithms, for example involving the invariant mass of pairs of L1 candidates, were also implemented. The upgrades reduced the trigger rate from background processes and increased the efficiency for a variety of physics signals. This poster highlights a number of improvements that the upgraded L1 Trigger provided during the Run 2 program at CMS.CMS-CR-2020-272oai:cds.cern.ch:27925632020-12-10
spellingShingle Detectors and Experimental Techniques
Kwon, Hyejin
Performance of the CMS Level-1 Trigger during Run 2
title Performance of the CMS Level-1 Trigger during Run 2
title_full Performance of the CMS Level-1 Trigger during Run 2
title_fullStr Performance of the CMS Level-1 Trigger during Run 2
title_full_unstemmed Performance of the CMS Level-1 Trigger during Run 2
title_short Performance of the CMS Level-1 Trigger during Run 2
title_sort performance of the cms level-1 trigger during run 2
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/2792563
work_keys_str_mv AT kwonhyejin performanceofthecmslevel1triggerduringrun2