Performance of the CMS Level-1 Trigger during Run 2
The CMS Level-1 (L1) Trigger system was upgraded in 2016 in order to cope with the threefold increase in peak luminosity of Run 2 compared to Run 1. The upgraded trigger features advanced clustering, calibration, and particle identification techniques. More sophisticated algorithms, for example invo...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2020
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/2792563 |
_version_ | 1780972367278768128 |
---|---|
author | Kwon, Hyejin |
author_facet | Kwon, Hyejin |
author_sort | Kwon, Hyejin |
collection | CERN |
description | The CMS Level-1 (L1) Trigger system was upgraded in 2016 in order to cope with the threefold increase in peak luminosity of Run 2 compared to Run 1. The upgraded trigger features advanced clustering, calibration, and particle identification techniques. More sophisticated algorithms, for example involving the invariant mass of pairs of L1 candidates, were also implemented. The upgrades reduced the trigger rate from background processes and increased the efficiency for a variety of physics signals. This poster highlights a number of improvements that the upgraded L1 Trigger provided during the Run 2 program at CMS. |
id | cern-2792563 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2020 |
record_format | invenio |
spelling | cern-27925632021-12-10T19:48:16Zhttp://cds.cern.ch/record/2792563engKwon, HyejinPerformance of the CMS Level-1 Trigger during Run 2Detectors and Experimental TechniquesThe CMS Level-1 (L1) Trigger system was upgraded in 2016 in order to cope with the threefold increase in peak luminosity of Run 2 compared to Run 1. The upgraded trigger features advanced clustering, calibration, and particle identification techniques. More sophisticated algorithms, for example involving the invariant mass of pairs of L1 candidates, were also implemented. The upgrades reduced the trigger rate from background processes and increased the efficiency for a variety of physics signals. This poster highlights a number of improvements that the upgraded L1 Trigger provided during the Run 2 program at CMS.CMS-CR-2020-272oai:cds.cern.ch:27925632020-12-10 |
spellingShingle | Detectors and Experimental Techniques Kwon, Hyejin Performance of the CMS Level-1 Trigger during Run 2 |
title | Performance of the CMS Level-1 Trigger during Run 2 |
title_full | Performance of the CMS Level-1 Trigger during Run 2 |
title_fullStr | Performance of the CMS Level-1 Trigger during Run 2 |
title_full_unstemmed | Performance of the CMS Level-1 Trigger during Run 2 |
title_short | Performance of the CMS Level-1 Trigger during Run 2 |
title_sort | performance of the cms level-1 trigger during run 2 |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/2792563 |
work_keys_str_mv | AT kwonhyejin performanceofthecmslevel1triggerduringrun2 |