Cargando…

CMS RPC Background -- Studies and Measurements

The expected radiation background in the CMS RPC system has been studied using the MC prediction with the CMS FLUKA simulation of the detector and the cavern. The MC geometry used in the analysis describes very accurately the present RPC system but still does not include the complete description of...

Descripción completa

Detalles Bibliográficos
Autores principales: Hadjiiska, R., Samalan, A., Tytgat, M., Zaganidis, N., Alves, G.A., Marujo, F., Torres Da Silva De Araujo, F., Da Costa, E.M., De Jesus Damiao, D., Nogima, H., Santoro, A., Fonseca De Souza, S., Aleksandrov, A., Iaydjiev, P., Rodozov, M., Shopova, M., Sultanov, G., Bonchev, M., Dimitrov, A., Litov, L., Pavlov, B., Petkov, P., Petrov, A., Qian, S.J., Bernal, C., Cabrera, A., Fraga, J., Sarkar, A., Elsayed, S., Assran, Y., El Sawy, M., Mahmoud, M.A., Mohammed, Y., Combaret, C., Gouzevitch, M., Grenier, G., Laktineh, I., Mirabito, L., Shchablo, K., Bagaturia, I., Lomidze, D., Lomidze, I., Bhatnagar, V., Gupta, R., Kumari, P., Singh, J., Amoozegar, V., Boghrati, B., Ebraimi, M., Ghasemi, R., Mohammadi Najafabadi, M., Zareian, E., Abbrescia, M., Aly, R., Elmetenawee, W., De Filippis, N., Gelmi, A., Iaselli, G., Leszki, S., Loddo, F., Margjeka, I., Pugliese, G., Ramos, D., Caponero, M., Benussi, L., Bianco, S., Colafranceschi, S., Russo, A., Passamonti, L., Piccolo, D., Pierluigi, D., Saviano, G., Buontempo, S., Di Crescenzo, A., Fienga, F., De Lellis, G., Lista, L., Meola, S., Paolucci, P., Braghieri, A., Salvini, P., Montagna, P., Riccardi, C., Vitulo, P., Francois, B., Kim, T.J., Park, J., Choi, S.Y., Hong, B., Lee, K.S., Goh, J., Lee, H., Eysermans, J., Uribe Estrada, C., Pedraza, I., Castilla-Valdez, H., Sanchez-Hernandez, A., Mondragon Herrera, C.A., Perez Navarro, D.A., Ayala Sanchez, G.A., Carrillo, S., Vazquez, E., Radi, A., Ahmad, A., Asghar, I., Hoorani, H., Muhammad, S., Shah, M.A., Crotty, I.
Lenguaje:eng
Publicado: 2020
Materias:
Acceso en línea:https://dx.doi.org/10.1088/1748-0221/16/04/C04005
http://cds.cern.ch/record/2792676
Descripción
Sumario:The expected radiation background in the CMS RPC system has been studied using the MC prediction with the CMS FLUKA simulation of the detector and the cavern. The MC geometry used in the analysis describes very accurately the present RPC system but still does not include the complete description of the RPC upgrade region with pseudorapidity $1.9 < \lvert \eta \rvert < 2.4$. Present results are ready to be updated with the final geometry description. The radiation background has been studied in terms of expected particle rates, absorbed dose and fluence. Two High Luminosity LHC (HL-LHC) scenarios have been investigated - after collecting $3000$ and $4000$ fb$^{-1}$. Estimations with safety factor of 3 have been considered, as well.