Cargando…
HGCROC3: the front-end readout ASIC for the CMS High Granularity Calorimeter
For the CMS High Granularity Calorimeter (CE), the final version of the 72-channel front-end ASIC (HGCROC3) was submitted in December 2020. HGCROC3 includes low-noise/high-gain preamplifiers/shapers and a 10-bit 40 MHz successive approximation ADC (SAR-ADC) that provide the charge measurement over t...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2021
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1088/1748-0221/17/03/C03015 http://cds.cern.ch/record/2797658 |
_version_ | 1780972407908990976 |
---|---|
author | Dulucq, Frederic |
author_facet | Dulucq, Frederic |
author_sort | Dulucq, Frederic |
collection | CERN |
description | For the CMS High Granularity Calorimeter (CE), the final version of the 72-channel front-end ASIC (HGCROC3) was submitted in December 2020. HGCROC3 includes low-noise/high-gain preamplifiers/shapers and a 10-bit 40 MHz successive approximation ADC (SAR-ADC) that provide the charge measurement over the linear range of the preamplifier. In the saturation range, a discriminator and a time-to-digital converter (TDC) provide the charge information from the time over threshold (ToT; 200 ns dynamic range, 50 ps binning). A fast discriminator and another TDC provide timing information to 25 ps accuracy. The chip embeds all necessary ancillary services: bandgap circuit, PLL, threshold DACs. We present the experimental results on the latest and final version (HGCROC3) received in April 2021. |
id | cern-2797658 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2021 |
record_format | invenio |
spelling | cern-27976582023-03-08T12:07:07Zdoi:10.1088/1748-0221/17/03/C03015http://cds.cern.ch/record/2797658engDulucq, FredericHGCROC3: the front-end readout ASIC for the CMS High Granularity CalorimeterDetectors and Experimental TechniquesFor the CMS High Granularity Calorimeter (CE), the final version of the 72-channel front-end ASIC (HGCROC3) was submitted in December 2020. HGCROC3 includes low-noise/high-gain preamplifiers/shapers and a 10-bit 40 MHz successive approximation ADC (SAR-ADC) that provide the charge measurement over the linear range of the preamplifier. In the saturation range, a discriminator and a time-to-digital converter (TDC) provide the charge information from the time over threshold (ToT; 200 ns dynamic range, 50 ps binning). A fast discriminator and another TDC provide timing information to 25 ps accuracy. The chip embeds all necessary ancillary services: bandgap circuit, PLL, threshold DACs. We present the experimental results on the latest and final version (HGCROC3) received in April 2021.CMS-CR-2021-191oai:cds.cern.ch:27976582021-10-11 |
spellingShingle | Detectors and Experimental Techniques Dulucq, Frederic HGCROC3: the front-end readout ASIC for the CMS High Granularity Calorimeter |
title | HGCROC3: the front-end readout ASIC for the CMS High Granularity Calorimeter |
title_full | HGCROC3: the front-end readout ASIC for the CMS High Granularity Calorimeter |
title_fullStr | HGCROC3: the front-end readout ASIC for the CMS High Granularity Calorimeter |
title_full_unstemmed | HGCROC3: the front-end readout ASIC for the CMS High Granularity Calorimeter |
title_short | HGCROC3: the front-end readout ASIC for the CMS High Granularity Calorimeter |
title_sort | hgcroc3: the front-end readout asic for the cms high granularity calorimeter |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1088/1748-0221/17/03/C03015 http://cds.cern.ch/record/2797658 |
work_keys_str_mv | AT dulucqfrederic hgcroc3thefrontendreadoutasicforthecmshighgranularitycalorimeter |