Cargando…

Testbeam performance results of bent ALPIDE Monolithic Active Pixel Sensors in view of the ALICE Inner Tracking System 3

The ALICE Inner Tracking System has been recently upgraded to a full silicon detector consisting entirely of monolithic active pixel sensors, arranged in seven concentric layers around the LHC beam pipe. Further ahead, during the LHC Long Shutdown 3, the ALICE collaboration is planning to replace th...

Descripción completa

Detalles Bibliográficos
Autor principal: Blidaru, Bogdan-Mihail
Lenguaje:eng
Publicado: 2021
Materias:
Acceso en línea:https://dx.doi.org/10.1088/1748-0221/17/09/C09006
http://cds.cern.ch/record/2798678
_version_ 1780972491133419520
author Blidaru, Bogdan-Mihail
author_facet Blidaru, Bogdan-Mihail
author_sort Blidaru, Bogdan-Mihail
collection CERN
description The ALICE Inner Tracking System has been recently upgraded to a full silicon detector consisting entirely of monolithic active pixel sensors, arranged in seven concentric layers around the LHC beam pipe. Further ahead, during the LHC Long Shutdown 3, the ALICE collaboration is planning to replace the three innermost layers of this new ITS with a novel vertex detector. The proposed design features wafer-scale, ultra-thin, truly cylindrical MAPS. The new sensors will be thinned down to 20–40 µm, featuring a material budget of less than 0.05% x/X $_{0}$ per layer, unprecedented low, and will be arranged concentrically around the beam pipe, as close as 18 mm from the interaction point.Anticipating the first prototypes in the new 65 nm CMOS technology node, an active R&D programme is underway to test the response to bending of existing 50 µm thick ALPIDE sensors. A number of such chips were successfully bent, even below the targeted innermost radius, without signs of mechanical damage, while retaining their full electrical functionality in laboratory tests. The curved detectors were subsequently tested during particle beam campaigns, where their particle detection performance was assessed.In this contribution, testbeam highlights from the data analysis of bent ALPIDE sensors, will be presented. It was proved that the current ALPIDE produced in the 180 nm CMOS technology retains its properties after bending. The results show an inefficiency that is generally below 10$^{−4}$, independent of the inclination and position of the impinging beam with respect to the sensor surface. This encouraging outcome proves that the use of curved MAPS is an exciting possibility for future silicon detector designs, as not only the sensor can survive the bending exercise mechanically, but the enticing attributes that make it attractive for use in the inner tracking layers are comparable to the flat state.
id cern-2798678
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2021
record_format invenio
spelling cern-27986782023-02-02T10:04:48Zdoi:10.1088/1748-0221/17/09/C09006http://cds.cern.ch/record/2798678engBlidaru, Bogdan-MihailTestbeam performance results of bent ALPIDE Monolithic Active Pixel Sensors in view of the ALICE Inner Tracking System 3Detectors and Experimental TechniquesThe ALICE Inner Tracking System has been recently upgraded to a full silicon detector consisting entirely of monolithic active pixel sensors, arranged in seven concentric layers around the LHC beam pipe. Further ahead, during the LHC Long Shutdown 3, the ALICE collaboration is planning to replace the three innermost layers of this new ITS with a novel vertex detector. The proposed design features wafer-scale, ultra-thin, truly cylindrical MAPS. The new sensors will be thinned down to 20–40 µm, featuring a material budget of less than 0.05% x/X $_{0}$ per layer, unprecedented low, and will be arranged concentrically around the beam pipe, as close as 18 mm from the interaction point.Anticipating the first prototypes in the new 65 nm CMOS technology node, an active R&D programme is underway to test the response to bending of existing 50 µm thick ALPIDE sensors. A number of such chips were successfully bent, even below the targeted innermost radius, without signs of mechanical damage, while retaining their full electrical functionality in laboratory tests. The curved detectors were subsequently tested during particle beam campaigns, where their particle detection performance was assessed.In this contribution, testbeam highlights from the data analysis of bent ALPIDE sensors, will be presented. It was proved that the current ALPIDE produced in the 180 nm CMOS technology retains its properties after bending. The results show an inefficiency that is generally below 10$^{−4}$, independent of the inclination and position of the impinging beam with respect to the sensor surface. This encouraging outcome proves that the use of curved MAPS is an exciting possibility for future silicon detector designs, as not only the sensor can survive the bending exercise mechanically, but the enticing attributes that make it attractive for use in the inner tracking layers are comparable to the flat state.The ALICE Inner Tracking System has been recently upgraded to a full silicon detector consisting entirely of MAPS, arranged in seven concentric layers around the LHC beam pipe. Further ahead, during the LHC Long Shutdown 3, the ALICE collaboration is planning to replace the three innermost layers of this new ITS with a novel vertex detector. The proposed design features wafer-scale, ultra-thin, truly cylindrical MAPS. The new sensors will be thinned down to 20-40~µm, featuring a material budget of less than 0.05%~x/$\mathrm{X_{0}}$ per layer, unprecedented low, and will be arranged concentrically around the beam pipe, as close as 18~mm from the interaction point. Anticipating the first prototypes in the new 65~nm CMOS technology node, an active R&D programme is underway to test the response to bending of existing 50~µm thick ALPIDE sensors. A number of such chips were successfully bent, even below the targeted innermost radius, without signs of mechanical damage, while retaining their full electrical functionality in laboratory tests. The curved detectors were subsequently tested during particle beam campaigns, where their particle detection performance was assessed. In this contribution, testbeam highlights from the data analysis of bent ALPIDE sensors, will be presented. It was proved that the current ALPIDE produced in the 180~nm CMOS technology retains its properties after bending. The results show an inefficiency that is generally below $10^{-4}$, independent of the inclination and position of the impinging beam with respect to the sensor surface. This encouraging outcome proves that the use of curved MAPS is an exciting possibility for future silicon detector designs, as not only the sensor can survive the bending exercise mechanically, but the enticing attributes that make it attractive for use in the inner tracking layers are comparable to the flat state.arXiv:2112.10414oai:cds.cern.ch:27986782021-12-20
spellingShingle Detectors and Experimental Techniques
Blidaru, Bogdan-Mihail
Testbeam performance results of bent ALPIDE Monolithic Active Pixel Sensors in view of the ALICE Inner Tracking System 3
title Testbeam performance results of bent ALPIDE Monolithic Active Pixel Sensors in view of the ALICE Inner Tracking System 3
title_full Testbeam performance results of bent ALPIDE Monolithic Active Pixel Sensors in view of the ALICE Inner Tracking System 3
title_fullStr Testbeam performance results of bent ALPIDE Monolithic Active Pixel Sensors in view of the ALICE Inner Tracking System 3
title_full_unstemmed Testbeam performance results of bent ALPIDE Monolithic Active Pixel Sensors in view of the ALICE Inner Tracking System 3
title_short Testbeam performance results of bent ALPIDE Monolithic Active Pixel Sensors in view of the ALICE Inner Tracking System 3
title_sort testbeam performance results of bent alpide monolithic active pixel sensors in view of the alice inner tracking system 3
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1088/1748-0221/17/09/C09006
http://cds.cern.ch/record/2798678
work_keys_str_mv AT blidarubogdanmihail testbeamperformanceresultsofbentalpidemonolithicactivepixelsensorsinviewofthealiceinnertrackingsystem3