Cargando…

Preliminary Design of the Support Structure for a Rotating Carbon-Ion Transfer Line for Medical Applications

The development of new bent superconducting magnets together with the optimization of the support structure open the way to a considerable reduction in the weight and complexity of rotating gantries for medical applications. The magnets, which define the transfer line to deliver carbon ions to the p...

Descripción completa

Detalles Bibliográficos
Autores principales: Perini, Diego, Dassa, Luca, Piacentini, Luca, Uberti, Stefano
Lenguaje:eng
Publicado: 2021
Materias:
Acceso en línea:https://dx.doi.org/10.3390/instruments5040034
http://cds.cern.ch/record/2799369
_version_ 1780972541777543168
author Perini, Diego
Dassa, Luca
Piacentini, Luca
Uberti, Stefano
author_facet Perini, Diego
Dassa, Luca
Piacentini, Luca
Uberti, Stefano
author_sort Perini, Diego
collection CERN
description The development of new bent superconducting magnets together with the optimization of the support structure open the way to a considerable reduction in the weight and complexity of rotating gantries for medical applications. The magnets, which define the transfer line to deliver carbon ions to the patients from different angles, are supported by a rotating structure that should be as rigid and as lightweight as possible. Relative displacements of the magnets due to deformations cause incorrect beam position and consequent errors in hitting the target tissues. This paper describes a possible rotating structure which is considerably lighter than the previous designs. A method to compensate part of the deformation by complementary rotations of the driving motor is proposed. The influence of the construction tolerances and deformations of the supports is also analyzed and alignment and adjustment possibilities are discussed.
id cern-2799369
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2021
record_format invenio
spelling cern-27993692022-01-12T21:02:29Zdoi:10.3390/instruments5040034http://cds.cern.ch/record/2799369engPerini, DiegoDassa, LucaPiacentini, LucaUberti, StefanoPreliminary Design of the Support Structure for a Rotating Carbon-Ion Transfer Line for Medical ApplicationsDetectors and Experimental TechniquesThe development of new bent superconducting magnets together with the optimization of the support structure open the way to a considerable reduction in the weight and complexity of rotating gantries for medical applications. The magnets, which define the transfer line to deliver carbon ions to the patients from different angles, are supported by a rotating structure that should be as rigid and as lightweight as possible. Relative displacements of the magnets due to deformations cause incorrect beam position and consequent errors in hitting the target tissues. This paper describes a possible rotating structure which is considerably lighter than the previous designs. A method to compensate part of the deformation by complementary rotations of the driving motor is proposed. The influence of the construction tolerances and deformations of the supports is also analyzed and alignment and adjustment possibilities are discussed.oai:cds.cern.ch:27993692021
spellingShingle Detectors and Experimental Techniques
Perini, Diego
Dassa, Luca
Piacentini, Luca
Uberti, Stefano
Preliminary Design of the Support Structure for a Rotating Carbon-Ion Transfer Line for Medical Applications
title Preliminary Design of the Support Structure for a Rotating Carbon-Ion Transfer Line for Medical Applications
title_full Preliminary Design of the Support Structure for a Rotating Carbon-Ion Transfer Line for Medical Applications
title_fullStr Preliminary Design of the Support Structure for a Rotating Carbon-Ion Transfer Line for Medical Applications
title_full_unstemmed Preliminary Design of the Support Structure for a Rotating Carbon-Ion Transfer Line for Medical Applications
title_short Preliminary Design of the Support Structure for a Rotating Carbon-Ion Transfer Line for Medical Applications
title_sort preliminary design of the support structure for a rotating carbon-ion transfer line for medical applications
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.3390/instruments5040034
http://cds.cern.ch/record/2799369
work_keys_str_mv AT perinidiego preliminarydesignofthesupportstructureforarotatingcarboniontransferlineformedicalapplications
AT dassaluca preliminarydesignofthesupportstructureforarotatingcarboniontransferlineformedicalapplications
AT piacentiniluca preliminarydesignofthesupportstructureforarotatingcarboniontransferlineformedicalapplications
AT ubertistefano preliminarydesignofthesupportstructureforarotatingcarboniontransferlineformedicalapplications