Cargando…
Intercomparison of personal and ambient dosimeters in extremely high-dose-rate pulsed photon fields
Recent advances in laser driven accelerators boosted the development of high dose-rate fast pulsed systems all over the world. The stray radiation comprises primarily high-energy photons, resulting in extremely high dose rates within pico-/femto-second pulses. Dose measurements in such conditions ha...
Autores principales: | , , , , , , , , , , , , |
---|---|
Publicado: |
2020
|
Acceso en línea: | https://dx.doi.org/10.1016/j.radphyschem.2020.108764 http://cds.cern.ch/record/2800282 |
_version_ | 1780972622678327296 |
---|---|
author | Zorloni, Gabriele Ambrožová, Iva Carbonez, Pierre Caresana, Marco Ebert, Stephan Olšovcová, Veronika Pitzschke, Andreas Ploc, Ondrej Pozzi, Fabio Silari, Marco Trompier, Francois Trunecek, Roman Zelenka, Zdenek |
author_facet | Zorloni, Gabriele Ambrožová, Iva Carbonez, Pierre Caresana, Marco Ebert, Stephan Olšovcová, Veronika Pitzschke, Andreas Ploc, Ondrej Pozzi, Fabio Silari, Marco Trompier, Francois Trunecek, Roman Zelenka, Zdenek |
author_sort | Zorloni, Gabriele |
collection | CERN |
description | Recent advances in laser driven accelerators boosted the development of high dose-rate fast pulsed systems all over the world. The stray radiation comprises primarily high-energy photons, resulting in extremely high dose rates within pico-/femto-second pulses. Dose measurements in such conditions have to be evaluated to validate methods. To tackle this challenge the EUropean RAdiation DOSimetry Group (EURADOS) started a program of dosimeters intercomparison, with a progressive approach, starting by a first evaluation in fields with μs pulse duration. The first comparison took place at the Lausanne University Hospital Center with an electron LINAC in Sept. 2017 involving 7 European institutes. Several passive and active dosimeters were tested with a tunable air kerma per pulse of the order of MGy/h. All instruments, except electrets, did not show any dose rate dependence, thus being selected as possible candidates for further studies. |
id | cern-2800282 |
institution | Organización Europea para la Investigación Nuclear |
publishDate | 2020 |
record_format | invenio |
spelling | cern-28002822022-01-24T22:51:05Zdoi:10.1016/j.radphyschem.2020.108764http://cds.cern.ch/record/2800282Zorloni, GabrieleAmbrožová, IvaCarbonez, PierreCaresana, MarcoEbert, StephanOlšovcová, VeronikaPitzschke, AndreasPloc, OndrejPozzi, FabioSilari, MarcoTrompier, FrancoisTrunecek, RomanZelenka, ZdenekIntercomparison of personal and ambient dosimeters in extremely high-dose-rate pulsed photon fieldsRecent advances in laser driven accelerators boosted the development of high dose-rate fast pulsed systems all over the world. The stray radiation comprises primarily high-energy photons, resulting in extremely high dose rates within pico-/femto-second pulses. Dose measurements in such conditions have to be evaluated to validate methods. To tackle this challenge the EUropean RAdiation DOSimetry Group (EURADOS) started a program of dosimeters intercomparison, with a progressive approach, starting by a first evaluation in fields with μs pulse duration. The first comparison took place at the Lausanne University Hospital Center with an electron LINAC in Sept. 2017 involving 7 European institutes. Several passive and active dosimeters were tested with a tunable air kerma per pulse of the order of MGy/h. All instruments, except electrets, did not show any dose rate dependence, thus being selected as possible candidates for further studies.oai:cds.cern.ch:28002822020 |
spellingShingle | Zorloni, Gabriele Ambrožová, Iva Carbonez, Pierre Caresana, Marco Ebert, Stephan Olšovcová, Veronika Pitzschke, Andreas Ploc, Ondrej Pozzi, Fabio Silari, Marco Trompier, Francois Trunecek, Roman Zelenka, Zdenek Intercomparison of personal and ambient dosimeters in extremely high-dose-rate pulsed photon fields |
title | Intercomparison of personal and ambient dosimeters in extremely high-dose-rate pulsed photon fields |
title_full | Intercomparison of personal and ambient dosimeters in extremely high-dose-rate pulsed photon fields |
title_fullStr | Intercomparison of personal and ambient dosimeters in extremely high-dose-rate pulsed photon fields |
title_full_unstemmed | Intercomparison of personal and ambient dosimeters in extremely high-dose-rate pulsed photon fields |
title_short | Intercomparison of personal and ambient dosimeters in extremely high-dose-rate pulsed photon fields |
title_sort | intercomparison of personal and ambient dosimeters in extremely high-dose-rate pulsed photon fields |
url | https://dx.doi.org/10.1016/j.radphyschem.2020.108764 http://cds.cern.ch/record/2800282 |
work_keys_str_mv | AT zorlonigabriele intercomparisonofpersonalandambientdosimetersinextremelyhighdoseratepulsedphotonfields AT ambrozovaiva intercomparisonofpersonalandambientdosimetersinextremelyhighdoseratepulsedphotonfields AT carbonezpierre intercomparisonofpersonalandambientdosimetersinextremelyhighdoseratepulsedphotonfields AT caresanamarco intercomparisonofpersonalandambientdosimetersinextremelyhighdoseratepulsedphotonfields AT ebertstephan intercomparisonofpersonalandambientdosimetersinextremelyhighdoseratepulsedphotonfields AT olsovcovaveronika intercomparisonofpersonalandambientdosimetersinextremelyhighdoseratepulsedphotonfields AT pitzschkeandreas intercomparisonofpersonalandambientdosimetersinextremelyhighdoseratepulsedphotonfields AT plocondrej intercomparisonofpersonalandambientdosimetersinextremelyhighdoseratepulsedphotonfields AT pozzifabio intercomparisonofpersonalandambientdosimetersinextremelyhighdoseratepulsedphotonfields AT silarimarco intercomparisonofpersonalandambientdosimetersinextremelyhighdoseratepulsedphotonfields AT trompierfrancois intercomparisonofpersonalandambientdosimetersinextremelyhighdoseratepulsedphotonfields AT trunecekroman intercomparisonofpersonalandambientdosimetersinextremelyhighdoseratepulsedphotonfields AT zelenkazdenek intercomparisonofpersonalandambientdosimetersinextremelyhighdoseratepulsedphotonfields |