Non-invasive beam profile monitor for medical accelerators
A beam profile monitor based on a supersonic gas-curtain is currently under development for transverse profile diagnostics of electron and proton beams in the High Luminosity LHC. This monitor uses a thin supersonic gas curtain that crosses the primary beam to be characterized under an angle of 45 d...
Autores principales: | , , , , , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2020
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/j.ejmp.2020.04.023 http://cds.cern.ch/record/2801424 |
_version_ | 1780972695042654208 |
---|---|
author | Kumar, N Salehilashkajani, A Zhang, H D Ady, M Forck, P Glutting, J Jones, O R Kersevan, R Marriott-Doddington, T Mazzoni, S Rossi, A Schneider, G Udrea, S Veness, R Welsch, C P |
author_facet | Kumar, N Salehilashkajani, A Zhang, H D Ady, M Forck, P Glutting, J Jones, O R Kersevan, R Marriott-Doddington, T Mazzoni, S Rossi, A Schneider, G Udrea, S Veness, R Welsch, C P |
author_sort | Kumar, N |
collection | CERN |
description | A beam profile monitor based on a supersonic gas-curtain is currently under development for transverse profile
diagnostics of electron and proton beams in the High Luminosity LHC. This monitor uses a thin supersonic gas
curtain that crosses the primary beam to be characterized under an angle of 45 degrees. The fluorescence caused
by the interaction between the beam and gas-curtain is detected using a specially designed imaging system to
determine the 2D transverse profile of the primary beam. Another prototype monitor based on beam induced
ionization is installed at The Cockcroft Institute. This paper presents the design features of both the monitors, the
gas-jet curtain formation and various experimental tests, including profile measurements of an electron beam,
using helium, nitrogen and neon as gases. Such a non-invasive online beam profile monitor would be highly
desirable also for medical LINAC’s and storage rings as it can characterize the beam without stopping machine
operation. The paper discusses opportunities for simplifying the monitor design for integration into a medical
accelerator and expected monitor performance. |
id | cern-2801424 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2020 |
record_format | invenio |
spelling | cern-28014242022-10-31T15:38:59Zdoi:10.1016/j.ejmp.2020.04.023http://cds.cern.ch/record/2801424engKumar, NSalehilashkajani, AZhang, H DAdy, MForck, PGlutting, JJones, O RKersevan, RMarriott-Doddington, TMazzoni, SRossi, ASchneider, GUdrea, SVeness, RWelsch, C PNon-invasive beam profile monitor for medical acceleratorsHealth Physics and Radiation EffectsA beam profile monitor based on a supersonic gas-curtain is currently under development for transverse profile diagnostics of electron and proton beams in the High Luminosity LHC. This monitor uses a thin supersonic gas curtain that crosses the primary beam to be characterized under an angle of 45 degrees. The fluorescence caused by the interaction between the beam and gas-curtain is detected using a specially designed imaging system to determine the 2D transverse profile of the primary beam. Another prototype monitor based on beam induced ionization is installed at The Cockcroft Institute. This paper presents the design features of both the monitors, the gas-jet curtain formation and various experimental tests, including profile measurements of an electron beam, using helium, nitrogen and neon as gases. Such a non-invasive online beam profile monitor would be highly desirable also for medical LINAC’s and storage rings as it can characterize the beam without stopping machine operation. The paper discusses opportunities for simplifying the monitor design for integration into a medical accelerator and expected monitor performance.oai:cds.cern.ch:28014242020 |
spellingShingle | Health Physics and Radiation Effects Kumar, N Salehilashkajani, A Zhang, H D Ady, M Forck, P Glutting, J Jones, O R Kersevan, R Marriott-Doddington, T Mazzoni, S Rossi, A Schneider, G Udrea, S Veness, R Welsch, C P Non-invasive beam profile monitor for medical accelerators |
title | Non-invasive beam profile monitor for medical accelerators |
title_full | Non-invasive beam profile monitor for medical accelerators |
title_fullStr | Non-invasive beam profile monitor for medical accelerators |
title_full_unstemmed | Non-invasive beam profile monitor for medical accelerators |
title_short | Non-invasive beam profile monitor for medical accelerators |
title_sort | non-invasive beam profile monitor for medical accelerators |
topic | Health Physics and Radiation Effects |
url | https://dx.doi.org/10.1016/j.ejmp.2020.04.023 http://cds.cern.ch/record/2801424 |
work_keys_str_mv | AT kumarn noninvasivebeamprofilemonitorformedicalaccelerators AT salehilashkajania noninvasivebeamprofilemonitorformedicalaccelerators AT zhanghd noninvasivebeamprofilemonitorformedicalaccelerators AT adym noninvasivebeamprofilemonitorformedicalaccelerators AT forckp noninvasivebeamprofilemonitorformedicalaccelerators AT gluttingj noninvasivebeamprofilemonitorformedicalaccelerators AT jonesor noninvasivebeamprofilemonitorformedicalaccelerators AT kersevanr noninvasivebeamprofilemonitorformedicalaccelerators AT marriottdoddingtont noninvasivebeamprofilemonitorformedicalaccelerators AT mazzonis noninvasivebeamprofilemonitorformedicalaccelerators AT rossia noninvasivebeamprofilemonitorformedicalaccelerators AT schneiderg noninvasivebeamprofilemonitorformedicalaccelerators AT udreas noninvasivebeamprofilemonitorformedicalaccelerators AT venessr noninvasivebeamprofilemonitorformedicalaccelerators AT welschcp noninvasivebeamprofilemonitorformedicalaccelerators |