Cargando…

Particle Flow with a Hybrid Segmented Crystal and Fiber Dual-Readout Calorimeter

In the reconstruction of physics events at future e$^{+}$e$^{-}$ colliders the calorimeter design has a crucial role in the overall detector performance. The reconstruction of events with many jets in their final state sets stringent requirements on the jet energy and angular resolutions. The en...

Descripción completa

Detalles Bibliográficos
Autores principales: Lucchini, Marco T., Pezzotti, Lorenzo, Polesello, Giacomo, Tully, Christopher G.
Lenguaje:eng
Publicado: 2022
Materias:
Acceso en línea:https://dx.doi.org/10.1088/1748-0221/17/06/P06008
http://cds.cern.ch/record/2801827
_version_ 1780972722868715520
author Lucchini, Marco T.
Pezzotti, Lorenzo
Polesello, Giacomo
Tully, Christopher G.
author_facet Lucchini, Marco T.
Pezzotti, Lorenzo
Polesello, Giacomo
Tully, Christopher G.
author_sort Lucchini, Marco T.
collection CERN
description In the reconstruction of physics events at future e$^{+}$e$^{-}$ colliders the calorimeter design has a crucial role in the overall detector performance. The reconstruction of events with many jets in their final state sets stringent requirements on the jet energy and angular resolutions. The energy resolution for jets with energy of about 45 GeV is required to be at the 4–5% level to enable an efficient separation of the W and Z boson invariant masses. We demonstrate in this paper how such a performance can be achieved by exploiting a particle flow algorithm tailored for a hybrid dual-readout calorimeter made of segmented crystals and fibers. The excellent energy resolution and linearity of such calorimeter for both photons and neutral hadrons (3%/√E and 26%/√E, respectively), inherent to the homogeneous crystals and dual-readout technological choices, provides a powerful handle for the development of a new approach for particle identification and jet reconstruction. While the dual-readout particle flow algorithm (DR-PFA) presented in this paper is at its early stage of development, it already demonstrates the potential of a hybrid dual-readout calorimeter for jet reconstruction by improving the jet energy resolution with respect to a calorimeter-only reconstruction from 6.0% to about 4.5% for 45 GeV jets.
id cern-2801827
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2022
record_format invenio
spelling cern-28018272023-06-29T04:02:07Zdoi:10.1088/1748-0221/17/06/P06008http://cds.cern.ch/record/2801827engLucchini, Marco T.Pezzotti, LorenzoPolesello, GiacomoTully, Christopher G.Particle Flow with a Hybrid Segmented Crystal and Fiber Dual-Readout CalorimeterDetectors and Experimental TechniquesParticle Physics - ExperimentIn the reconstruction of physics events at future e$^{+}$e$^{-}$ colliders the calorimeter design has a crucial role in the overall detector performance. The reconstruction of events with many jets in their final state sets stringent requirements on the jet energy and angular resolutions. The energy resolution for jets with energy of about 45 GeV is required to be at the 4–5% level to enable an efficient separation of the W and Z boson invariant masses. We demonstrate in this paper how such a performance can be achieved by exploiting a particle flow algorithm tailored for a hybrid dual-readout calorimeter made of segmented crystals and fibers. The excellent energy resolution and linearity of such calorimeter for both photons and neutral hadrons (3%/√E and 26%/√E, respectively), inherent to the homogeneous crystals and dual-readout technological choices, provides a powerful handle for the development of a new approach for particle identification and jet reconstruction. While the dual-readout particle flow algorithm (DR-PFA) presented in this paper is at its early stage of development, it already demonstrates the potential of a hybrid dual-readout calorimeter for jet reconstruction by improving the jet energy resolution with respect to a calorimeter-only reconstruction from 6.0% to about 4.5% for 45 GeV jets.In the reconstruction of physics events at future e$^+$e$^-$ colliders the calorimeter design has a crucial role in the overall detector performance. The reconstruction of events with many jets in their final state sets stringent requirements on the jet energy and angular resolutions. The energy resolution for jets with energy of about 45 GeV is required to be at the 4-5% level to enable an efficient separation of the W and Z boson invariant masses. We demonstrate in this paper how such a performance can be achieved by exploiting a particle flow algorithm tailored for a hybrid dual-readout calorimeter made of segmented crystals and fibers. The excellent energy resolution and linearity of such calorimeter for both photons and neutral hadrons ($3\%/\sqrt{E}$ and $26\%/\sqrt{E}$, respectively), inherent to the homogeneous crystals and dual-readout technological choices, provides a powerful handle for the development of a new approach for particle identification and jet reconstruction. While the dual-readout particle flow algorithm (DR-PFA) presented in this paper is at its early stage of development, it already demonstrates the potential of a hybrid dual-readout calorimeter for jet reconstruction by improving the jet energy resolution with respect to a calorimeter-only reconstruction from 6.0% to about 4.5% for 45 GeV jets.arXiv:2202.01474oai:cds.cern.ch:28018272022-02-03
spellingShingle Detectors and Experimental Techniques
Particle Physics - Experiment
Lucchini, Marco T.
Pezzotti, Lorenzo
Polesello, Giacomo
Tully, Christopher G.
Particle Flow with a Hybrid Segmented Crystal and Fiber Dual-Readout Calorimeter
title Particle Flow with a Hybrid Segmented Crystal and Fiber Dual-Readout Calorimeter
title_full Particle Flow with a Hybrid Segmented Crystal and Fiber Dual-Readout Calorimeter
title_fullStr Particle Flow with a Hybrid Segmented Crystal and Fiber Dual-Readout Calorimeter
title_full_unstemmed Particle Flow with a Hybrid Segmented Crystal and Fiber Dual-Readout Calorimeter
title_short Particle Flow with a Hybrid Segmented Crystal and Fiber Dual-Readout Calorimeter
title_sort particle flow with a hybrid segmented crystal and fiber dual-readout calorimeter
topic Detectors and Experimental Techniques
Particle Physics - Experiment
url https://dx.doi.org/10.1088/1748-0221/17/06/P06008
http://cds.cern.ch/record/2801827
work_keys_str_mv AT lucchinimarcot particleflowwithahybridsegmentedcrystalandfiberdualreadoutcalorimeter
AT pezzottilorenzo particleflowwithahybridsegmentedcrystalandfiberdualreadoutcalorimeter
AT polesellogiacomo particleflowwithahybridsegmentedcrystalandfiberdualreadoutcalorimeter
AT tullychristopherg particleflowwithahybridsegmentedcrystalandfiberdualreadoutcalorimeter