Cargando…

Capacity control of induced draft cooling tower using two stage optimization

We consider the problem of designing a capacity control method for induced draft cooling towers that can be operated in different modes (bypass, showering, ventilation) to meet the heat rejection requirement. Recent efforts provide an adequate solution using mixed integer model predictive controller...

Descripción completa

Detalles Bibliográficos
Autores principales: Ghawash, Faiq, Hovd, Morten, Schofield, Brad
Lenguaje:eng
Publicado: 2021
Materias:
Acceso en línea:https://dx.doi.org/10.1109/icstcc52150.2021.9607294
http://cds.cern.ch/record/2806343
_version_ 1780972990743183360
author Ghawash, Faiq
Hovd, Morten
Schofield, Brad
author_facet Ghawash, Faiq
Hovd, Morten
Schofield, Brad
author_sort Ghawash, Faiq
collection CERN
description We consider the problem of designing a capacity control method for induced draft cooling towers that can be operated in different modes (bypass, showering, ventilation) to meet the heat rejection requirement. Recent efforts provide an adequate solution using mixed integer model predictive controller, however the combinatorial formulation of the problem might result in prohibitively large computation time limiting its applicability in real time scenarios. To this end, we propose a computationally efficient capacity control method based on a two stage optimization approach for handling the mode selection and optimal fan speed of the cooling tower. The solution to the first stage optimization program provides optimal fan speed which is then utilized by the second stage optimization program to determine the best operational mode of the cooling tower. An algorithm is proposed which relies on the integration of autonomous dynamics of bypass and showering mode and the relationship between showering and ventilation mode to efficiently solve the two stage optimization problem. Numerical simulations are provided to validate the performance of the proposed capacity control method.
id cern-2806343
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2021
record_format invenio
spelling cern-28063432022-08-09T14:57:13Zdoi:10.1109/icstcc52150.2021.9607294http://cds.cern.ch/record/2806343engGhawash, FaiqHovd, MortenSchofield, BradCapacity control of induced draft cooling tower using two stage optimizationDetectors and Experimental TechniquesAccelerators and Storage RingsWe consider the problem of designing a capacity control method for induced draft cooling towers that can be operated in different modes (bypass, showering, ventilation) to meet the heat rejection requirement. Recent efforts provide an adequate solution using mixed integer model predictive controller, however the combinatorial formulation of the problem might result in prohibitively large computation time limiting its applicability in real time scenarios. To this end, we propose a computationally efficient capacity control method based on a two stage optimization approach for handling the mode selection and optimal fan speed of the cooling tower. The solution to the first stage optimization program provides optimal fan speed which is then utilized by the second stage optimization program to determine the best operational mode of the cooling tower. An algorithm is proposed which relies on the integration of autonomous dynamics of bypass and showering mode and the relationship between showering and ventilation mode to efficiently solve the two stage optimization problem. Numerical simulations are provided to validate the performance of the proposed capacity control method.oai:cds.cern.ch:28063432021
spellingShingle Detectors and Experimental Techniques
Accelerators and Storage Rings
Ghawash, Faiq
Hovd, Morten
Schofield, Brad
Capacity control of induced draft cooling tower using two stage optimization
title Capacity control of induced draft cooling tower using two stage optimization
title_full Capacity control of induced draft cooling tower using two stage optimization
title_fullStr Capacity control of induced draft cooling tower using two stage optimization
title_full_unstemmed Capacity control of induced draft cooling tower using two stage optimization
title_short Capacity control of induced draft cooling tower using two stage optimization
title_sort capacity control of induced draft cooling tower using two stage optimization
topic Detectors and Experimental Techniques
Accelerators and Storage Rings
url https://dx.doi.org/10.1109/icstcc52150.2021.9607294
http://cds.cern.ch/record/2806343
work_keys_str_mv AT ghawashfaiq capacitycontrolofinduceddraftcoolingtowerusingtwostageoptimization
AT hovdmorten capacitycontrolofinduceddraftcoolingtowerusingtwostageoptimization
AT schofieldbrad capacitycontrolofinduceddraftcoolingtowerusingtwostageoptimization