Cargando…

Novel ionisation vacuum gauge suitable as a reference standard: Influence of primary electron trajectories on the operation

A detailed study of the operation of a novel ionisation gauge, recently proposed as a reference standard by the consortium of the European project 16NRM05, is performed with focus on the influence of electron trajectories and the interaction of electrons with electrode surfaces. The strategy behind...

Descripción completa

Detalles Bibliográficos
Autores principales: Bundaleski, N, Adame, C F, Bernien, M, Illgen, C, Jenninger, B, Jousten, K, Scuderi, F, Silva, R A S, Stöltzel, A, Šetina, J, Teodoro, O M N D, Verbovšek, T, Vičar, M, Wüest, M
Lenguaje:eng
Publicado: 2022
Acceso en línea:https://dx.doi.org/10.1016/j.vacuum.2022.111041
http://cds.cern.ch/record/2806712
_version_ 1780973010063196160
author Bundaleski, N
Adame, C F
Bernien, M
Illgen, C
Jenninger, B
Jousten, K
Scuderi, F
Silva, R A S
Stöltzel, A
Šetina, J
Teodoro, O M N D
Verbovšek, T
Vičar, M
Wüest, M
author_facet Bundaleski, N
Adame, C F
Bernien, M
Illgen, C
Jenninger, B
Jousten, K
Scuderi, F
Silva, R A S
Stöltzel, A
Šetina, J
Teodoro, O M N D
Verbovšek, T
Vičar, M
Wüest, M
author_sort Bundaleski, N
collection CERN
description A detailed study of the operation of a novel ionisation gauge, recently proposed as a reference standard by the consortium of the European project 16NRM05, is performed with focus on the influence of electron trajectories and the interaction of electrons with electrode surfaces. The strategy behind the gauge design was to provide well defined primary electron trajectories that form an electron beam. This investigation seeks to correlate experimental investigations of improper primary beam focusing, electron beam profiling, electron stimulated desorption and outgassing, with charged particle optics simulations that include space charge effects, and a detailed study of secondary electron emission. The main outcome of the research is that control of the primary electron trajectories, quantified by electron transmission efficiency, is essential for its proper operation mainly as a pressure measurement device but also as a vacuum gauge sensitivity reference standard. Once all primary electrons end their trajectories in a Faraday cup, being one of the gauge electrodes, two additional problems are identified: escape of a very small fraction of electrons from the Faraday cup and electron stimulated desorption of neutrals. Their contribution is of low significance when using this device as a sensitivity reference standard in the high vacuum range, which meets the major goal of the 16NRM05 project. However, these effects might represent an obstacle for the gauge application, mainly as a measurement device, at lower pressures. Approaches to mitigate the mentioned potential problems are discussed.
id cern-2806712
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2022
record_format invenio
spelling cern-28067122022-04-14T20:50:14Zdoi:10.1016/j.vacuum.2022.111041http://cds.cern.ch/record/2806712engBundaleski, NAdame, C FBernien, MIllgen, CJenninger, BJousten, KScuderi, FSilva, R A SStöltzel, AŠetina, JTeodoro, O M N DVerbovšek, TVičar, MWüest, MNovel ionisation vacuum gauge suitable as a reference standard: Influence of primary electron trajectories on the operationA detailed study of the operation of a novel ionisation gauge, recently proposed as a reference standard by the consortium of the European project 16NRM05, is performed with focus on the influence of electron trajectories and the interaction of electrons with electrode surfaces. The strategy behind the gauge design was to provide well defined primary electron trajectories that form an electron beam. This investigation seeks to correlate experimental investigations of improper primary beam focusing, electron beam profiling, electron stimulated desorption and outgassing, with charged particle optics simulations that include space charge effects, and a detailed study of secondary electron emission. The main outcome of the research is that control of the primary electron trajectories, quantified by electron transmission efficiency, is essential for its proper operation mainly as a pressure measurement device but also as a vacuum gauge sensitivity reference standard. Once all primary electrons end their trajectories in a Faraday cup, being one of the gauge electrodes, two additional problems are identified: escape of a very small fraction of electrons from the Faraday cup and electron stimulated desorption of neutrals. Their contribution is of low significance when using this device as a sensitivity reference standard in the high vacuum range, which meets the major goal of the 16NRM05 project. However, these effects might represent an obstacle for the gauge application, mainly as a measurement device, at lower pressures. Approaches to mitigate the mentioned potential problems are discussed.oai:cds.cern.ch:28067122022
spellingShingle Bundaleski, N
Adame, C F
Bernien, M
Illgen, C
Jenninger, B
Jousten, K
Scuderi, F
Silva, R A S
Stöltzel, A
Šetina, J
Teodoro, O M N D
Verbovšek, T
Vičar, M
Wüest, M
Novel ionisation vacuum gauge suitable as a reference standard: Influence of primary electron trajectories on the operation
title Novel ionisation vacuum gauge suitable as a reference standard: Influence of primary electron trajectories on the operation
title_full Novel ionisation vacuum gauge suitable as a reference standard: Influence of primary electron trajectories on the operation
title_fullStr Novel ionisation vacuum gauge suitable as a reference standard: Influence of primary electron trajectories on the operation
title_full_unstemmed Novel ionisation vacuum gauge suitable as a reference standard: Influence of primary electron trajectories on the operation
title_short Novel ionisation vacuum gauge suitable as a reference standard: Influence of primary electron trajectories on the operation
title_sort novel ionisation vacuum gauge suitable as a reference standard: influence of primary electron trajectories on the operation
url https://dx.doi.org/10.1016/j.vacuum.2022.111041
http://cds.cern.ch/record/2806712
work_keys_str_mv AT bundaleskin novelionisationvacuumgaugesuitableasareferencestandardinfluenceofprimaryelectrontrajectoriesontheoperation
AT adamecf novelionisationvacuumgaugesuitableasareferencestandardinfluenceofprimaryelectrontrajectoriesontheoperation
AT bernienm novelionisationvacuumgaugesuitableasareferencestandardinfluenceofprimaryelectrontrajectoriesontheoperation
AT illgenc novelionisationvacuumgaugesuitableasareferencestandardinfluenceofprimaryelectrontrajectoriesontheoperation
AT jenningerb novelionisationvacuumgaugesuitableasareferencestandardinfluenceofprimaryelectrontrajectoriesontheoperation
AT joustenk novelionisationvacuumgaugesuitableasareferencestandardinfluenceofprimaryelectrontrajectoriesontheoperation
AT scuderif novelionisationvacuumgaugesuitableasareferencestandardinfluenceofprimaryelectrontrajectoriesontheoperation
AT silvaras novelionisationvacuumgaugesuitableasareferencestandardinfluenceofprimaryelectrontrajectoriesontheoperation
AT stoltzela novelionisationvacuumgaugesuitableasareferencestandardinfluenceofprimaryelectrontrajectoriesontheoperation
AT setinaj novelionisationvacuumgaugesuitableasareferencestandardinfluenceofprimaryelectrontrajectoriesontheoperation
AT teodoroomnd novelionisationvacuumgaugesuitableasareferencestandardinfluenceofprimaryelectrontrajectoriesontheoperation
AT verbovsekt novelionisationvacuumgaugesuitableasareferencestandardinfluenceofprimaryelectrontrajectoriesontheoperation
AT vicarm novelionisationvacuumgaugesuitableasareferencestandardinfluenceofprimaryelectrontrajectoriesontheoperation
AT wuestm novelionisationvacuumgaugesuitableasareferencestandardinfluenceofprimaryelectrontrajectoriesontheoperation