Cargando…
Phase 1 Upgrade of the CMS Hadron Calorimeter
The Phase 1 upgrade of the CMS Hadron Calorimeter detector (HCAL) involved installing silicon photomultipliers (SiPM) to measure the scintillator light output with better signal/noise and upgrading the read-out electronics, allowing for increased longitudinal segmentation and better performance. Thi...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2022
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/j.nima.2022.167389 http://cds.cern.ch/record/2810162 |
_version_ | 1780973205224161280 |
---|---|
author | Isik, Candan |
author_facet | Isik, Candan |
author_sort | Isik, Candan |
collection | CERN |
description | The Phase 1 upgrade of the CMS Hadron Calorimeter detector (HCAL) involved installing silicon photomultipliers (SiPM) to measure the scintillator light output with better signal/noise and upgrading the read-out electronics, allowing for increased longitudinal segmentation and better performance. This talk will summarize the design, testing, installation, and commissioning of the HCAL Phase 1 upgrade. Performance results for the HCAL endcap and forward detectors using Run 2 data will be presented, together with prospects for Run 3. |
id | cern-2810162 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2022 |
record_format | invenio |
spelling | cern-28101622022-09-27T06:41:10Zdoi:10.1016/j.nima.2022.167389http://cds.cern.ch/record/2810162engIsik, CandanPhase 1 Upgrade of the CMS Hadron CalorimeterDetectors and Experimental TechniquesThe Phase 1 upgrade of the CMS Hadron Calorimeter detector (HCAL) involved installing silicon photomultipliers (SiPM) to measure the scintillator light output with better signal/noise and upgrading the read-out electronics, allowing for increased longitudinal segmentation and better performance. This talk will summarize the design, testing, installation, and commissioning of the HCAL Phase 1 upgrade. Performance results for the HCAL endcap and forward detectors using Run 2 data will be presented, together with prospects for Run 3.CMS-CR-2022-049oai:cds.cern.ch:28101622022-03-25 |
spellingShingle | Detectors and Experimental Techniques Isik, Candan Phase 1 Upgrade of the CMS Hadron Calorimeter |
title | Phase 1 Upgrade of the CMS Hadron Calorimeter |
title_full | Phase 1 Upgrade of the CMS Hadron Calorimeter |
title_fullStr | Phase 1 Upgrade of the CMS Hadron Calorimeter |
title_full_unstemmed | Phase 1 Upgrade of the CMS Hadron Calorimeter |
title_short | Phase 1 Upgrade of the CMS Hadron Calorimeter |
title_sort | phase 1 upgrade of the cms hadron calorimeter |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1016/j.nima.2022.167389 http://cds.cern.ch/record/2810162 |
work_keys_str_mv | AT isikcandan phase1upgradeofthecmshadroncalorimeter |