Cargando…

Phase 1 Upgrade of the CMS Hadron Calorimeter

The Phase 1 upgrade of the CMS Hadron Calorimeter detector (HCAL) involved installing silicon photomultipliers (SiPM) to measure the scintillator light output with better signal/noise and upgrading the read-out electronics, allowing for increased longitudinal segmentation and better performance. Thi...

Descripción completa

Detalles Bibliográficos
Autor principal: Isik, Candan
Lenguaje:eng
Publicado: 2022
Materias:
Acceso en línea:https://dx.doi.org/10.1016/j.nima.2022.167389
http://cds.cern.ch/record/2810162
_version_ 1780973205224161280
author Isik, Candan
author_facet Isik, Candan
author_sort Isik, Candan
collection CERN
description The Phase 1 upgrade of the CMS Hadron Calorimeter detector (HCAL) involved installing silicon photomultipliers (SiPM) to measure the scintillator light output with better signal/noise and upgrading the read-out electronics, allowing for increased longitudinal segmentation and better performance. This talk will summarize the design, testing, installation, and commissioning of the HCAL Phase 1 upgrade. Performance results for the HCAL endcap and forward detectors using Run 2 data will be presented, together with prospects for Run 3.
id cern-2810162
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2022
record_format invenio
spelling cern-28101622022-09-27T06:41:10Zdoi:10.1016/j.nima.2022.167389http://cds.cern.ch/record/2810162engIsik, CandanPhase 1 Upgrade of the CMS Hadron CalorimeterDetectors and Experimental TechniquesThe Phase 1 upgrade of the CMS Hadron Calorimeter detector (HCAL) involved installing silicon photomultipliers (SiPM) to measure the scintillator light output with better signal/noise and upgrading the read-out electronics, allowing for increased longitudinal segmentation and better performance. This talk will summarize the design, testing, installation, and commissioning of the HCAL Phase 1 upgrade. Performance results for the HCAL endcap and forward detectors using Run 2 data will be presented, together with prospects for Run 3.CMS-CR-2022-049oai:cds.cern.ch:28101622022-03-25
spellingShingle Detectors and Experimental Techniques
Isik, Candan
Phase 1 Upgrade of the CMS Hadron Calorimeter
title Phase 1 Upgrade of the CMS Hadron Calorimeter
title_full Phase 1 Upgrade of the CMS Hadron Calorimeter
title_fullStr Phase 1 Upgrade of the CMS Hadron Calorimeter
title_full_unstemmed Phase 1 Upgrade of the CMS Hadron Calorimeter
title_short Phase 1 Upgrade of the CMS Hadron Calorimeter
title_sort phase 1 upgrade of the cms hadron calorimeter
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1016/j.nima.2022.167389
http://cds.cern.ch/record/2810162
work_keys_str_mv AT isikcandan phase1upgradeofthecmshadroncalorimeter