Cargando…

Feasibility Study of ChDR Diagnostic Device in the LHC

In recent years Cherenkov Diffraction Radiation (ChDR) has been reported as a phenomenon suitable for various types of particle accelerator diagnostics. As it would typically work best for highly relativistic beam, past studies and experiments have been mostly focusing on the lepton machines. This c...

Descripción completa

Detalles Bibliográficos
Autores principales: Łasocha, Kacper, Bergamaschi, Michele, Harryman, Daniel M, Karataev, Pavel, Krupa, Michal, Lefèvre, Thibaut, Mazzoni, Stefano, Mounet, Nicolas, Potylitsyn, Alexander, Schloegelhofer, Andreas, Senes, Eugenio
Lenguaje:eng
Publicado: JACoW 2021
Materias:
Acceso en línea:https://dx.doi.org/10.18429/JACoW-IPAC2021-TUPAB283
http://cds.cern.ch/record/2811870
_version_ 1780973311890554880
author Łasocha, Kacper
Bergamaschi, Michele
Harryman, Daniel M
Karataev, Pavel
Krupa, Michal
Lefèvre, Thibaut
Mazzoni, Stefano
Mounet, Nicolas
Potylitsyn, Alexander
Schloegelhofer, Andreas
Senes, Eugenio
author_facet Łasocha, Kacper
Bergamaschi, Michele
Harryman, Daniel M
Karataev, Pavel
Krupa, Michal
Lefèvre, Thibaut
Mazzoni, Stefano
Mounet, Nicolas
Potylitsyn, Alexander
Schloegelhofer, Andreas
Senes, Eugenio
author_sort Łasocha, Kacper
collection CERN
description In recent years Cherenkov Diffraction Radiation (ChDR) has been reported as a phenomenon suitable for various types of particle accelerator diagnostics. As it would typically work best for highly relativistic beam, past studies and experiments have been mostly focusing on the lepton machines. This contribution investigates the prospects on the utilization of ChDR as a diagnostic tool for the Large Hadron Collider (LHC). Based on theoretical considerations and simulation results we estimate the properties of the expected radiation, both in the incoherent and coherent domain, and we compare them with the requirements of the existing diagnostic systems. We also address the potential problem of the use of dielectric radiators in circular machines, where secondary electrons could potentially lead to the creation of electron clouds inside the beam pipe that may affect the radiator.
id cern-2811870
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2021
publisher JACoW
record_format invenio
spelling cern-28118702022-06-10T23:32:21Zdoi:10.18429/JACoW-IPAC2021-TUPAB283http://cds.cern.ch/record/2811870engŁasocha, KacperBergamaschi, MicheleHarryman, Daniel MKarataev, PavelKrupa, MichalLefèvre, ThibautMazzoni, StefanoMounet, NicolasPotylitsyn, AlexanderSchloegelhofer, AndreasSenes, EugenioFeasibility Study of ChDR Diagnostic Device in the LHCAccelerators and Storage RingsIn recent years Cherenkov Diffraction Radiation (ChDR) has been reported as a phenomenon suitable for various types of particle accelerator diagnostics. As it would typically work best for highly relativistic beam, past studies and experiments have been mostly focusing on the lepton machines. This contribution investigates the prospects on the utilization of ChDR as a diagnostic tool for the Large Hadron Collider (LHC). Based on theoretical considerations and simulation results we estimate the properties of the expected radiation, both in the incoherent and coherent domain, and we compare them with the requirements of the existing diagnostic systems. We also address the potential problem of the use of dielectric radiators in circular machines, where secondary electrons could potentially lead to the creation of electron clouds inside the beam pipe that may affect the radiator.JACoWoai:cds.cern.ch:28118702021
spellingShingle Accelerators and Storage Rings
Łasocha, Kacper
Bergamaschi, Michele
Harryman, Daniel M
Karataev, Pavel
Krupa, Michal
Lefèvre, Thibaut
Mazzoni, Stefano
Mounet, Nicolas
Potylitsyn, Alexander
Schloegelhofer, Andreas
Senes, Eugenio
Feasibility Study of ChDR Diagnostic Device in the LHC
title Feasibility Study of ChDR Diagnostic Device in the LHC
title_full Feasibility Study of ChDR Diagnostic Device in the LHC
title_fullStr Feasibility Study of ChDR Diagnostic Device in the LHC
title_full_unstemmed Feasibility Study of ChDR Diagnostic Device in the LHC
title_short Feasibility Study of ChDR Diagnostic Device in the LHC
title_sort feasibility study of chdr diagnostic device in the lhc
topic Accelerators and Storage Rings
url https://dx.doi.org/10.18429/JACoW-IPAC2021-TUPAB283
http://cds.cern.ch/record/2811870
work_keys_str_mv AT łasochakacper feasibilitystudyofchdrdiagnosticdeviceinthelhc
AT bergamaschimichele feasibilitystudyofchdrdiagnosticdeviceinthelhc
AT harrymandanielm feasibilitystudyofchdrdiagnosticdeviceinthelhc
AT karataevpavel feasibilitystudyofchdrdiagnosticdeviceinthelhc
AT krupamichal feasibilitystudyofchdrdiagnosticdeviceinthelhc
AT lefevrethibaut feasibilitystudyofchdrdiagnosticdeviceinthelhc
AT mazzonistefano feasibilitystudyofchdrdiagnosticdeviceinthelhc
AT mounetnicolas feasibilitystudyofchdrdiagnosticdeviceinthelhc
AT potylitsynalexander feasibilitystudyofchdrdiagnosticdeviceinthelhc
AT schloegelhoferandreas feasibilitystudyofchdrdiagnosticdeviceinthelhc
AT seneseugenio feasibilitystudyofchdrdiagnosticdeviceinthelhc