Cargando…
A semi-passive beam dilution system for the FCC-ee collider
The operation modes for the proposed FCC-ee collider foresee a very small beam spot size and stored beam energies of up to 20.6 MJ in Z production. This necessitates a dedicated beam dumping system. To reduce the complexity of the system as well as to minimize the required space, an optimized, semi-...
Autores principales: | , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2022
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1140/epjti/s40485-022-00078-x http://cds.cern.ch/record/2812521 |
_version_ | 1780973344635486208 |
---|---|
author | Krainer, Alexander Bartmann, Wolfgang Calviani, Marco Dutheil, Yann Lechner, Anton Perillo Marcone, Antonio Ogur, Salim Ramjiawan, Rebecca |
author_facet | Krainer, Alexander Bartmann, Wolfgang Calviani, Marco Dutheil, Yann Lechner, Anton Perillo Marcone, Antonio Ogur, Salim Ramjiawan, Rebecca |
author_sort | Krainer, Alexander |
collection | CERN |
description | The operation modes for the proposed FCC-ee collider foresee a very small beam
spot size and stored beam energies of up to 20.6 MJ in Z production. This necessitates
a dedicated beam dumping system. To reduce the complexity of the system as well
as to minimize the required space, an optimized, semi-passive system has been
designed and is presented here. The beam dilution is done with a defocusing triplet
structure, followed by passive beam diluter elements (spoilers). This greatly reduces
the risk of possible dilution failure scenarios compared to an active dilution
kicker-magnet system. The dump core itself is located ∼70 m downstream of the
spoilers and is designed following the experience gained from the LHC dump.
The dilution performance as well as the interaction effects responsible for the
energy deposited in the spoiler, are directly related to the radiation length and the
dimension of the device in beam direction. Materials for these spoilers have been
studied extensively and key requirements have been identified using both Monte
Carlo shower simulations and thermo-mechanical Finite Element Analysis. Even
though the maximum temperature reached in the spoilers is well within the working
temperature range of the material, the induced mechanical stresses can lead to
material failure. Thermo-mechanical simulations have shown that the transversal
beam shape plays a key role in the magnitude of mechanical stresses as a result of the
beam impact and the abrupt temperature change. This problem is addressed in this
paper and an optimized solution is presented. |
id | cern-2812521 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2022 |
record_format | invenio |
spelling | cern-28125212022-07-06T14:09:10Zdoi:10.1140/epjti/s40485-022-00078-xhttp://cds.cern.ch/record/2812521engKrainer, AlexanderBartmann, WolfgangCalviani, MarcoDutheil, YannLechner, AntonPerillo Marcone, AntonioOgur, SalimRamjiawan, RebeccaA semi-passive beam dilution system for the FCC-ee colliderAccelerators and Storage RingsThe operation modes for the proposed FCC-ee collider foresee a very small beam spot size and stored beam energies of up to 20.6 MJ in Z production. This necessitates a dedicated beam dumping system. To reduce the complexity of the system as well as to minimize the required space, an optimized, semi-passive system has been designed and is presented here. The beam dilution is done with a defocusing triplet structure, followed by passive beam diluter elements (spoilers). This greatly reduces the risk of possible dilution failure scenarios compared to an active dilution kicker-magnet system. The dump core itself is located ∼70 m downstream of the spoilers and is designed following the experience gained from the LHC dump. The dilution performance as well as the interaction effects responsible for the energy deposited in the spoiler, are directly related to the radiation length and the dimension of the device in beam direction. Materials for these spoilers have been studied extensively and key requirements have been identified using both Monte Carlo shower simulations and thermo-mechanical Finite Element Analysis. Even though the maximum temperature reached in the spoilers is well within the working temperature range of the material, the induced mechanical stresses can lead to material failure. Thermo-mechanical simulations have shown that the transversal beam shape plays a key role in the magnitude of mechanical stresses as a result of the beam impact and the abrupt temperature change. This problem is addressed in this paper and an optimized solution is presented.oai:cds.cern.ch:28125212022 |
spellingShingle | Accelerators and Storage Rings Krainer, Alexander Bartmann, Wolfgang Calviani, Marco Dutheil, Yann Lechner, Anton Perillo Marcone, Antonio Ogur, Salim Ramjiawan, Rebecca A semi-passive beam dilution system for the FCC-ee collider |
title | A semi-passive beam dilution system for the FCC-ee collider |
title_full | A semi-passive beam dilution system for the FCC-ee collider |
title_fullStr | A semi-passive beam dilution system for the FCC-ee collider |
title_full_unstemmed | A semi-passive beam dilution system for the FCC-ee collider |
title_short | A semi-passive beam dilution system for the FCC-ee collider |
title_sort | semi-passive beam dilution system for the fcc-ee collider |
topic | Accelerators and Storage Rings |
url | https://dx.doi.org/10.1140/epjti/s40485-022-00078-x http://cds.cern.ch/record/2812521 |
work_keys_str_mv | AT kraineralexander asemipassivebeamdilutionsystemforthefcceecollider AT bartmannwolfgang asemipassivebeamdilutionsystemforthefcceecollider AT calvianimarco asemipassivebeamdilutionsystemforthefcceecollider AT dutheilyann asemipassivebeamdilutionsystemforthefcceecollider AT lechneranton asemipassivebeamdilutionsystemforthefcceecollider AT perillomarconeantonio asemipassivebeamdilutionsystemforthefcceecollider AT ogursalim asemipassivebeamdilutionsystemforthefcceecollider AT ramjiawanrebecca asemipassivebeamdilutionsystemforthefcceecollider AT kraineralexander semipassivebeamdilutionsystemforthefcceecollider AT bartmannwolfgang semipassivebeamdilutionsystemforthefcceecollider AT calvianimarco semipassivebeamdilutionsystemforthefcceecollider AT dutheilyann semipassivebeamdilutionsystemforthefcceecollider AT lechneranton semipassivebeamdilutionsystemforthefcceecollider AT perillomarconeantonio semipassivebeamdilutionsystemforthefcceecollider AT ogursalim semipassivebeamdilutionsystemforthefcceecollider AT ramjiawanrebecca semipassivebeamdilutionsystemforthefcceecollider |