Cargando…

A semi-passive beam dilution system for the FCC-ee collider

The operation modes for the proposed FCC-ee collider foresee a very small beam spot size and stored beam energies of up to 20.6 MJ in Z production. This necessitates a dedicated beam dumping system. To reduce the complexity of the system as well as to minimize the required space, an optimized, semi-...

Descripción completa

Detalles Bibliográficos
Autores principales: Krainer, Alexander, Bartmann, Wolfgang, Calviani, Marco, Dutheil, Yann, Lechner, Anton, Perillo Marcone, Antonio, Ogur, Salim, Ramjiawan, Rebecca
Lenguaje:eng
Publicado: 2022
Materias:
Acceso en línea:https://dx.doi.org/10.1140/epjti/s40485-022-00078-x
http://cds.cern.ch/record/2812521
_version_ 1780973344635486208
author Krainer, Alexander
Bartmann, Wolfgang
Calviani, Marco
Dutheil, Yann
Lechner, Anton
Perillo Marcone, Antonio
Ogur, Salim
Ramjiawan, Rebecca
author_facet Krainer, Alexander
Bartmann, Wolfgang
Calviani, Marco
Dutheil, Yann
Lechner, Anton
Perillo Marcone, Antonio
Ogur, Salim
Ramjiawan, Rebecca
author_sort Krainer, Alexander
collection CERN
description The operation modes for the proposed FCC-ee collider foresee a very small beam spot size and stored beam energies of up to 20.6 MJ in Z production. This necessitates a dedicated beam dumping system. To reduce the complexity of the system as well as to minimize the required space, an optimized, semi-passive system has been designed and is presented here. The beam dilution is done with a defocusing triplet structure, followed by passive beam diluter elements (spoilers). This greatly reduces the risk of possible dilution failure scenarios compared to an active dilution kicker-magnet system. The dump core itself is located ∼70 m downstream of the spoilers and is designed following the experience gained from the LHC dump. The dilution performance as well as the interaction effects responsible for the energy deposited in the spoiler, are directly related to the radiation length and the dimension of the device in beam direction. Materials for these spoilers have been studied extensively and key requirements have been identified using both Monte Carlo shower simulations and thermo-mechanical Finite Element Analysis. Even though the maximum temperature reached in the spoilers is well within the working temperature range of the material, the induced mechanical stresses can lead to material failure. Thermo-mechanical simulations have shown that the transversal beam shape plays a key role in the magnitude of mechanical stresses as a result of the beam impact and the abrupt temperature change. This problem is addressed in this paper and an optimized solution is presented.
id cern-2812521
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2022
record_format invenio
spelling cern-28125212022-07-06T14:09:10Zdoi:10.1140/epjti/s40485-022-00078-xhttp://cds.cern.ch/record/2812521engKrainer, AlexanderBartmann, WolfgangCalviani, MarcoDutheil, YannLechner, AntonPerillo Marcone, AntonioOgur, SalimRamjiawan, RebeccaA semi-passive beam dilution system for the FCC-ee colliderAccelerators and Storage RingsThe operation modes for the proposed FCC-ee collider foresee a very small beam spot size and stored beam energies of up to 20.6 MJ in Z production. This necessitates a dedicated beam dumping system. To reduce the complexity of the system as well as to minimize the required space, an optimized, semi-passive system has been designed and is presented here. The beam dilution is done with a defocusing triplet structure, followed by passive beam diluter elements (spoilers). This greatly reduces the risk of possible dilution failure scenarios compared to an active dilution kicker-magnet system. The dump core itself is located ∼70 m downstream of the spoilers and is designed following the experience gained from the LHC dump. The dilution performance as well as the interaction effects responsible for the energy deposited in the spoiler, are directly related to the radiation length and the dimension of the device in beam direction. Materials for these spoilers have been studied extensively and key requirements have been identified using both Monte Carlo shower simulations and thermo-mechanical Finite Element Analysis. Even though the maximum temperature reached in the spoilers is well within the working temperature range of the material, the induced mechanical stresses can lead to material failure. Thermo-mechanical simulations have shown that the transversal beam shape plays a key role in the magnitude of mechanical stresses as a result of the beam impact and the abrupt temperature change. This problem is addressed in this paper and an optimized solution is presented.oai:cds.cern.ch:28125212022
spellingShingle Accelerators and Storage Rings
Krainer, Alexander
Bartmann, Wolfgang
Calviani, Marco
Dutheil, Yann
Lechner, Anton
Perillo Marcone, Antonio
Ogur, Salim
Ramjiawan, Rebecca
A semi-passive beam dilution system for the FCC-ee collider
title A semi-passive beam dilution system for the FCC-ee collider
title_full A semi-passive beam dilution system for the FCC-ee collider
title_fullStr A semi-passive beam dilution system for the FCC-ee collider
title_full_unstemmed A semi-passive beam dilution system for the FCC-ee collider
title_short A semi-passive beam dilution system for the FCC-ee collider
title_sort semi-passive beam dilution system for the fcc-ee collider
topic Accelerators and Storage Rings
url https://dx.doi.org/10.1140/epjti/s40485-022-00078-x
http://cds.cern.ch/record/2812521
work_keys_str_mv AT kraineralexander asemipassivebeamdilutionsystemforthefcceecollider
AT bartmannwolfgang asemipassivebeamdilutionsystemforthefcceecollider
AT calvianimarco asemipassivebeamdilutionsystemforthefcceecollider
AT dutheilyann asemipassivebeamdilutionsystemforthefcceecollider
AT lechneranton asemipassivebeamdilutionsystemforthefcceecollider
AT perillomarconeantonio asemipassivebeamdilutionsystemforthefcceecollider
AT ogursalim asemipassivebeamdilutionsystemforthefcceecollider
AT ramjiawanrebecca asemipassivebeamdilutionsystemforthefcceecollider
AT kraineralexander semipassivebeamdilutionsystemforthefcceecollider
AT bartmannwolfgang semipassivebeamdilutionsystemforthefcceecollider
AT calvianimarco semipassivebeamdilutionsystemforthefcceecollider
AT dutheilyann semipassivebeamdilutionsystemforthefcceecollider
AT lechneranton semipassivebeamdilutionsystemforthefcceecollider
AT perillomarconeantonio semipassivebeamdilutionsystemforthefcceecollider
AT ogursalim semipassivebeamdilutionsystemforthefcceecollider
AT ramjiawanrebecca semipassivebeamdilutionsystemforthefcceecollider