Beam Loss Signal Calibration for the LHC Diamond Detectors During Run 2
Chemical Vapour Deposition (CVD) diamond detectors can be used as fast beam loss monitors in particle accelerators. In the Large Hadron Collider (LHC) at CERN, they are installed in the betatron collimation region, a high-radiation environment. In addition to their high-radiation tolerance, their ma...
Autores principales: | , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
JACoW
2021
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.18429/JACoW-IBIC2021-TUPP33 http://cds.cern.ch/record/2815640 |
_version_ | 1780973527609901056 |
---|---|
author | Morales Vigo, Sara Calvo Giraldo, Eva Effinger, Ewald Salvachua, Belen Welsch, Carsten P Wolfenden, Joseph Zamantzas, Christos |
author_facet | Morales Vigo, Sara Calvo Giraldo, Eva Effinger, Ewald Salvachua, Belen Welsch, Carsten P Wolfenden, Joseph Zamantzas, Christos |
author_sort | Morales Vigo, Sara |
collection | CERN |
description | Chemical Vapour Deposition (CVD) diamond detectors can be used as fast beam loss monitors in particle accelerators. In the Large Hadron Collider (LHC) at CERN, they are installed in the betatron collimation region, a high-radiation environment. In addition to their high-radiation tolerance, their main advantage is a time resolution of 1 ns which makes possible not only turn-by-turn, but also bunch-by-bunch loss measurements. An analysis of the LHC diamond beam loss monitor signals recorded during the last months of Run 2 (September 2018-November 2018) is presented with the aim of obtaining a signal-to-beam loss calibration. |
id | cern-2815640 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2021 |
publisher | JACoW |
record_format | invenio |
spelling | cern-28156402022-07-13T21:00:26Zdoi:10.18429/JACoW-IBIC2021-TUPP33http://cds.cern.ch/record/2815640engMorales Vigo, SaraCalvo Giraldo, EvaEffinger, EwaldSalvachua, BelenWelsch, Carsten PWolfenden, JosephZamantzas, ChristosBeam Loss Signal Calibration for the LHC Diamond Detectors During Run 2Accelerators and Storage RingsChemical Vapour Deposition (CVD) diamond detectors can be used as fast beam loss monitors in particle accelerators. In the Large Hadron Collider (LHC) at CERN, they are installed in the betatron collimation region, a high-radiation environment. In addition to their high-radiation tolerance, their main advantage is a time resolution of 1 ns which makes possible not only turn-by-turn, but also bunch-by-bunch loss measurements. An analysis of the LHC diamond beam loss monitor signals recorded during the last months of Run 2 (September 2018-November 2018) is presented with the aim of obtaining a signal-to-beam loss calibration.JACoWoai:cds.cern.ch:28156402021 |
spellingShingle | Accelerators and Storage Rings Morales Vigo, Sara Calvo Giraldo, Eva Effinger, Ewald Salvachua, Belen Welsch, Carsten P Wolfenden, Joseph Zamantzas, Christos Beam Loss Signal Calibration for the LHC Diamond Detectors During Run 2 |
title | Beam Loss Signal Calibration for the LHC Diamond Detectors During Run 2 |
title_full | Beam Loss Signal Calibration for the LHC Diamond Detectors During Run 2 |
title_fullStr | Beam Loss Signal Calibration for the LHC Diamond Detectors During Run 2 |
title_full_unstemmed | Beam Loss Signal Calibration for the LHC Diamond Detectors During Run 2 |
title_short | Beam Loss Signal Calibration for the LHC Diamond Detectors During Run 2 |
title_sort | beam loss signal calibration for the lhc diamond detectors during run 2 |
topic | Accelerators and Storage Rings |
url | https://dx.doi.org/10.18429/JACoW-IBIC2021-TUPP33 http://cds.cern.ch/record/2815640 |
work_keys_str_mv | AT moralesvigosara beamlosssignalcalibrationforthelhcdiamonddetectorsduringrun2 AT calvogiraldoeva beamlosssignalcalibrationforthelhcdiamonddetectorsduringrun2 AT effingerewald beamlosssignalcalibrationforthelhcdiamonddetectorsduringrun2 AT salvachuabelen beamlosssignalcalibrationforthelhcdiamonddetectorsduringrun2 AT welschcarstenp beamlosssignalcalibrationforthelhcdiamonddetectorsduringrun2 AT wolfendenjoseph beamlosssignalcalibrationforthelhcdiamonddetectorsduringrun2 AT zamantzaschristos beamlosssignalcalibrationforthelhcdiamonddetectorsduringrun2 |