Cargando…

Prototype Test for Electromagnetic Calorimeter, FOCAL, at CERN-SPS Using Large Dynamic Range Readout Electronics

A silicon–tungsten prototype calorimeter, for the proposed ALICE LS3-upgarde, was fabricated and tested at the CERN-SPS beamline facility in the year 2017. The calorimeter was designed with the help of GEANT4 simulation to perform in a high multiplicity density environment with optimised energy and...

Descripción completa

Detalles Bibliográficos
Autores principales: Muhuri, Sanjib, Chandra, Sinjini, Mukhopadhyay, Sourav, Saini, Jogender, Chandratre, V B, Singaraju, R N, Nayak, T K, van den Brink, Ton, Chattopadhyay, Subhasis
Lenguaje:eng
Publicado: Springer 2021
Materias:
Acceso en línea:https://dx.doi.org/10.1007/978-981-33-4408-2_116
http://cds.cern.ch/record/2824409
_version_ 1780973698442854400
author Muhuri, Sanjib
Chandra, Sinjini
Mukhopadhyay, Sourav
Saini, Jogender
Chandratre, V B
Singaraju, R N
Nayak, T K
van den Brink, Ton
Chattopadhyay, Subhasis
author_facet Muhuri, Sanjib
Chandra, Sinjini
Mukhopadhyay, Sourav
Saini, Jogender
Chandratre, V B
Singaraju, R N
Nayak, T K
van den Brink, Ton
Chattopadhyay, Subhasis
author_sort Muhuri, Sanjib
collection CERN
description A silicon–tungsten prototype calorimeter, for the proposed ALICE LS3-upgarde, was fabricated and tested at the CERN-SPS beamline facility in the year 2017. The calorimeter was designed with the help of GEANT4 simulation to perform in a high multiplicity density environment with optimised energy and position resolutions for incident energy up to 200 GeV. There were several tests conducted with different prototype configurations both at laboratory and CERN beamline facilities. The latest prototype in the series consists of 20 layers, each layer consisting of a 6 * 6 array of 1cm2 silicon pad detector, fabricated on a single 300 um thin wafer, and 1 radiation length (XR) thick, 10 cm * 10 cm pure tungsten plates as absorbers. Data was collected for pion, muon, and electron over a wide range of incident energies (20–180 GeV). Because of large energy deposition within the calorimeter by the electromagnetic showers, the readout electronics need to have a large dynamic range. Here, we will discuss the performances of the prototype, experimented at CERN-SPS, using a newly developed readout electronics (ANUINDRA) with a large dynamic range (up to 2.6 pC) and compare the improvements in this regard.
id cern-2824409
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2021
publisher Springer
record_format invenio
spelling cern-28244092022-08-11T18:17:05Zdoi:10.1007/978-981-33-4408-2_116http://cds.cern.ch/record/2824409engMuhuri, SanjibChandra, SinjiniMukhopadhyay, SouravSaini, JogenderChandratre, V BSingaraju, R NNayak, T Kvan den Brink, TonChattopadhyay, SubhasisPrototype Test for Electromagnetic Calorimeter, FOCAL, at CERN-SPS Using Large Dynamic Range Readout ElectronicsDetectors and Experimental TechniquesA silicon–tungsten prototype calorimeter, for the proposed ALICE LS3-upgarde, was fabricated and tested at the CERN-SPS beamline facility in the year 2017. The calorimeter was designed with the help of GEANT4 simulation to perform in a high multiplicity density environment with optimised energy and position resolutions for incident energy up to 200 GeV. There were several tests conducted with different prototype configurations both at laboratory and CERN beamline facilities. The latest prototype in the series consists of 20 layers, each layer consisting of a 6 * 6 array of 1cm2 silicon pad detector, fabricated on a single 300 um thin wafer, and 1 radiation length (XR) thick, 10 cm * 10 cm pure tungsten plates as absorbers. Data was collected for pion, muon, and electron over a wide range of incident energies (20–180 GeV). Because of large energy deposition within the calorimeter by the electromagnetic showers, the readout electronics need to have a large dynamic range. Here, we will discuss the performances of the prototype, experimented at CERN-SPS, using a newly developed readout electronics (ANUINDRA) with a large dynamic range (up to 2.6 pC) and compare the improvements in this regard.Springeroai:cds.cern.ch:28244092021
spellingShingle Detectors and Experimental Techniques
Muhuri, Sanjib
Chandra, Sinjini
Mukhopadhyay, Sourav
Saini, Jogender
Chandratre, V B
Singaraju, R N
Nayak, T K
van den Brink, Ton
Chattopadhyay, Subhasis
Prototype Test for Electromagnetic Calorimeter, FOCAL, at CERN-SPS Using Large Dynamic Range Readout Electronics
title Prototype Test for Electromagnetic Calorimeter, FOCAL, at CERN-SPS Using Large Dynamic Range Readout Electronics
title_full Prototype Test for Electromagnetic Calorimeter, FOCAL, at CERN-SPS Using Large Dynamic Range Readout Electronics
title_fullStr Prototype Test for Electromagnetic Calorimeter, FOCAL, at CERN-SPS Using Large Dynamic Range Readout Electronics
title_full_unstemmed Prototype Test for Electromagnetic Calorimeter, FOCAL, at CERN-SPS Using Large Dynamic Range Readout Electronics
title_short Prototype Test for Electromagnetic Calorimeter, FOCAL, at CERN-SPS Using Large Dynamic Range Readout Electronics
title_sort prototype test for electromagnetic calorimeter, focal, at cern-sps using large dynamic range readout electronics
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1007/978-981-33-4408-2_116
http://cds.cern.ch/record/2824409
work_keys_str_mv AT muhurisanjib prototypetestforelectromagneticcalorimeterfocalatcernspsusinglargedynamicrangereadoutelectronics
AT chandrasinjini prototypetestforelectromagneticcalorimeterfocalatcernspsusinglargedynamicrangereadoutelectronics
AT mukhopadhyaysourav prototypetestforelectromagneticcalorimeterfocalatcernspsusinglargedynamicrangereadoutelectronics
AT sainijogender prototypetestforelectromagneticcalorimeterfocalatcernspsusinglargedynamicrangereadoutelectronics
AT chandratrevb prototypetestforelectromagneticcalorimeterfocalatcernspsusinglargedynamicrangereadoutelectronics
AT singarajurn prototypetestforelectromagneticcalorimeterfocalatcernspsusinglargedynamicrangereadoutelectronics
AT nayaktk prototypetestforelectromagneticcalorimeterfocalatcernspsusinglargedynamicrangereadoutelectronics
AT vandenbrinkton prototypetestforelectromagneticcalorimeterfocalatcernspsusinglargedynamicrangereadoutelectronics
AT chattopadhyaysubhasis prototypetestforelectromagneticcalorimeterfocalatcernspsusinglargedynamicrangereadoutelectronics