Cargando…
Counting anti-protons with an MCP-SiPM setup to determine the absolute number of anti-protons in the ALPHA experiment
The ALPHA experiment studies the properties of anti-hydrogen to search for differences between matter and anti-matter. This project has focused on developing a new detection method using an MCP-SiPM setup to count individual anti-protons. The efficiency of this method to count anti-protons was deter...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2022
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/2824858 |
Sumario: | The ALPHA experiment studies the properties of anti-hydrogen to search for differences between matter and anti-matter. This project has focused on developing a new detection method using an MCP-SiPM setup to count individual anti-protons. The efficiency of this method to count anti-protons was determined to $93 \pm 4$ %. Using this calibration, the number of anti-protons was determined in various parts of the ALPHA experiment, allowing an estimation of the anti-proton loss in ALPHA-g to be about 53 %. |
---|