Cargando…

CERN Summer Student report: VTRx monitoring and Quality Control of the MFT detector in ALICE

The Muon Forward Tracker is one of the detectors implemented in ALICE as a part of the Run 3 upgrade. Using the ALPIDE silicon pixel sensor the detector provides wide range of improvements to the ALICE experiment. In order to fully exploit the improvements the MFT introduces, the control of data qua...

Descripción completa

Detalles Bibliográficos
Autor principal: Haidlova, Sara
Lenguaje:eng
Publicado: 2022
Materias:
Acceso en línea:http://cds.cern.ch/record/2824919
_version_ 1780973741585465344
author Haidlova, Sara
author_facet Haidlova, Sara
author_sort Haidlova, Sara
collection CERN
description The Muon Forward Tracker is one of the detectors implemented in ALICE as a part of the Run 3 upgrade. Using the ALPIDE silicon pixel sensor the detector provides wide range of improvements to the ALICE experiment. In order to fully exploit the improvements the MFT introduces, the control of data quality needs to be performed. This report presents the result of the VTRx monitoring that was performed in order to quantify the quality of data transfer from and to the detector. Second part is dedicated to Quality Control that is responsible for continuous data data quality.
id cern-2824919
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2022
record_format invenio
spelling cern-28249192022-08-19T19:21:33Zhttp://cds.cern.ch/record/2824919engHaidlova, SaraCERN Summer Student report: VTRx monitoring and Quality Control of the MFT detector in ALICEParticle Physics - ExperimentThe Muon Forward Tracker is one of the detectors implemented in ALICE as a part of the Run 3 upgrade. Using the ALPIDE silicon pixel sensor the detector provides wide range of improvements to the ALICE experiment. In order to fully exploit the improvements the MFT introduces, the control of data quality needs to be performed. This report presents the result of the VTRx monitoring that was performed in order to quantify the quality of data transfer from and to the detector. Second part is dedicated to Quality Control that is responsible for continuous data data quality.CERN-STUDENTS-Note-2022-044oai:cds.cern.ch:28249192022-08-19
spellingShingle Particle Physics - Experiment
Haidlova, Sara
CERN Summer Student report: VTRx monitoring and Quality Control of the MFT detector in ALICE
title CERN Summer Student report: VTRx monitoring and Quality Control of the MFT detector in ALICE
title_full CERN Summer Student report: VTRx monitoring and Quality Control of the MFT detector in ALICE
title_fullStr CERN Summer Student report: VTRx monitoring and Quality Control of the MFT detector in ALICE
title_full_unstemmed CERN Summer Student report: VTRx monitoring and Quality Control of the MFT detector in ALICE
title_short CERN Summer Student report: VTRx monitoring and Quality Control of the MFT detector in ALICE
title_sort cern summer student report: vtrx monitoring and quality control of the mft detector in alice
topic Particle Physics - Experiment
url http://cds.cern.ch/record/2824919
work_keys_str_mv AT haidlovasara cernsummerstudentreportvtrxmonitoringandqualitycontrolofthemftdetectorinalice