Cargando…
Response of the ATLAS Tile Calorimeter to single isolated charged hadrons
The response of the ATLAS hadronic Tile Calorimeter to single isolated charged hadrons is probed analysing of LHC proton-proton collisions data at √s = 13 TeV collected in 2017 and corresponding to an integrated luminosity of 144.9 pb-1. The calorimeter response is determined as the ratio of the ene...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2022
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/2827562 |
_version_ | 1780973924045029376 |
---|---|
author | Durglishvili, Archil |
author_facet | Durglishvili, Archil |
author_sort | Durglishvili, Archil |
collection | CERN |
description | The response of the ATLAS hadronic Tile Calorimeter to single isolated charged hadrons is probed analysing of LHC proton-proton collisions data at √s = 13 TeV collected in 2017 and corresponding to an integrated luminosity of 144.9 pb-1. The calorimeter response is determined as the ratio of the energy deposited in the calorimeter (E) divided by the momentum measured in the ATLAS Inner Detector (p). The average of E/p measured in data is 0.5896 ± 0.0001 (stat), compared to an expected value of 0.593 ± 0.001 (stat) obtained using Pythia8 simulated multijet events. A good agreement between experimental and simulated results is observed confirming the goodness of the calorimeter energy calibration at the EM scale. |
id | cern-2827562 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2022 |
record_format | invenio |
spelling | cern-28275622022-09-20T00:01:02Zhttp://cds.cern.ch/record/2827562engDurglishvili, ArchilResponse of the ATLAS Tile Calorimeter to single isolated charged hadronsParticle Physics - ExperimentThe response of the ATLAS hadronic Tile Calorimeter to single isolated charged hadrons is probed analysing of LHC proton-proton collisions data at √s = 13 TeV collected in 2017 and corresponding to an integrated luminosity of 144.9 pb-1. The calorimeter response is determined as the ratio of the energy deposited in the calorimeter (E) divided by the momentum measured in the ATLAS Inner Detector (p). The average of E/p measured in data is 0.5896 ± 0.0001 (stat), compared to an expected value of 0.593 ± 0.001 (stat) obtained using Pythia8 simulated multijet events. A good agreement between experimental and simulated results is observed confirming the goodness of the calorimeter energy calibration at the EM scale.ATL-TILECAL-SLIDE-2022-492oai:cds.cern.ch:28275622022-09-19 |
spellingShingle | Particle Physics - Experiment Durglishvili, Archil Response of the ATLAS Tile Calorimeter to single isolated charged hadrons |
title | Response of the ATLAS Tile Calorimeter to single isolated charged hadrons |
title_full | Response of the ATLAS Tile Calorimeter to single isolated charged hadrons |
title_fullStr | Response of the ATLAS Tile Calorimeter to single isolated charged hadrons |
title_full_unstemmed | Response of the ATLAS Tile Calorimeter to single isolated charged hadrons |
title_short | Response of the ATLAS Tile Calorimeter to single isolated charged hadrons |
title_sort | response of the atlas tile calorimeter to single isolated charged hadrons |
topic | Particle Physics - Experiment |
url | http://cds.cern.ch/record/2827562 |
work_keys_str_mv | AT durglishviliarchil responseoftheatlastilecalorimetertosingleisolatedchargedhadrons |