Cargando…

Pixelated resistive Micromegas detector for high-rate environment

The R&D; work reported in this paper has been devoted to the production and test of pixelated resistive micromegas detectors able to track particles in a high-rate environment, up to 10 MHz/cm$^2$, keeping a stable gain and a good spatial resolution. To pursue our goal, we had to reduce the occu...

Descripción completa

Detalles Bibliográficos
Autores principales: Alviggi, M, Camerlingo, M T, Della Pietra, M, Di Donato, C, Di Nardo, R, Franchellucci, S, Gimmillaro, C, Iengo, P, Iodice, M, Petrucci, F, Sekhniaidze, G, Sessa, M
Lenguaje:eng
Publicado: 2022
Materias:
Acceso en línea:https://dx.doi.org/10.1016/j.nima.2022.167310
http://cds.cern.ch/record/2834559
_version_ 1780975598469906432
author Alviggi, M
Camerlingo, M T
Della Pietra, M
Di Donato, C
Di Nardo, R
Franchellucci, S
Gimmillaro, C
Iengo, P
Iodice, M
Petrucci, F
Sekhniaidze, G
Sessa, M
author_facet Alviggi, M
Camerlingo, M T
Della Pietra, M
Di Donato, C
Di Nardo, R
Franchellucci, S
Gimmillaro, C
Iengo, P
Iodice, M
Petrucci, F
Sekhniaidze, G
Sessa, M
author_sort Alviggi, M
collection CERN
description The R&D; work reported in this paper has been devoted to the production and test of pixelated resistive micromegas detectors able to track particles in a high-rate environment, up to 10 MHz/cm$^2$, keeping a stable gain and a good spatial resolution. To pursue our goal, we had to reduce the occupancy by increasing the detector granularity and this has been done by changing the read-out anodes from the usual strips to pads. This minor change in the electrodes layout drastically increased the difficulty of implementing a resistive structure to protect the anodes from sparking. We present the results of the tests performed on four prototypes, with different protection schemes, showing it is possible to reach the desired rate with high gain, high efficiency and good position resolution. The response to X-rays from low ($^{55}$Fe source) to high (X-rays generator) rates, as well as to beams of ionizing particles is reported.
id cern-2834559
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2022
record_format invenio
spelling cern-28345592022-09-27T19:47:17Zdoi:10.1016/j.nima.2022.167310http://cds.cern.ch/record/2834559engAlviggi, MCamerlingo, M TDella Pietra, MDi Donato, CDi Nardo, RFranchellucci, SGimmillaro, CIengo, PIodice, MPetrucci, FSekhniaidze, GSessa, MPixelated resistive Micromegas detector for high-rate environmentDetectors and Experimental TechniquesThe R&D; work reported in this paper has been devoted to the production and test of pixelated resistive micromegas detectors able to track particles in a high-rate environment, up to 10 MHz/cm$^2$, keeping a stable gain and a good spatial resolution. To pursue our goal, we had to reduce the occupancy by increasing the detector granularity and this has been done by changing the read-out anodes from the usual strips to pads. This minor change in the electrodes layout drastically increased the difficulty of implementing a resistive structure to protect the anodes from sparking. We present the results of the tests performed on four prototypes, with different protection schemes, showing it is possible to reach the desired rate with high gain, high efficiency and good position resolution. The response to X-rays from low ($^{55}$Fe source) to high (X-rays generator) rates, as well as to beams of ionizing particles is reported.oai:cds.cern.ch:28345592022
spellingShingle Detectors and Experimental Techniques
Alviggi, M
Camerlingo, M T
Della Pietra, M
Di Donato, C
Di Nardo, R
Franchellucci, S
Gimmillaro, C
Iengo, P
Iodice, M
Petrucci, F
Sekhniaidze, G
Sessa, M
Pixelated resistive Micromegas detector for high-rate environment
title Pixelated resistive Micromegas detector for high-rate environment
title_full Pixelated resistive Micromegas detector for high-rate environment
title_fullStr Pixelated resistive Micromegas detector for high-rate environment
title_full_unstemmed Pixelated resistive Micromegas detector for high-rate environment
title_short Pixelated resistive Micromegas detector for high-rate environment
title_sort pixelated resistive micromegas detector for high-rate environment
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1016/j.nima.2022.167310
http://cds.cern.ch/record/2834559
work_keys_str_mv AT alviggim pixelatedresistivemicromegasdetectorforhighrateenvironment
AT camerlingomt pixelatedresistivemicromegasdetectorforhighrateenvironment
AT dellapietram pixelatedresistivemicromegasdetectorforhighrateenvironment
AT didonatoc pixelatedresistivemicromegasdetectorforhighrateenvironment
AT dinardor pixelatedresistivemicromegasdetectorforhighrateenvironment
AT franchelluccis pixelatedresistivemicromegasdetectorforhighrateenvironment
AT gimmillaroc pixelatedresistivemicromegasdetectorforhighrateenvironment
AT iengop pixelatedresistivemicromegasdetectorforhighrateenvironment
AT iodicem pixelatedresistivemicromegasdetectorforhighrateenvironment
AT petruccif pixelatedresistivemicromegasdetectorforhighrateenvironment
AT sekhniaidzeg pixelatedresistivemicromegasdetectorforhighrateenvironment
AT sessam pixelatedresistivemicromegasdetectorforhighrateenvironment