Cargando…
A kilometre-range distributed relative humidity sensor
Fibre optics sensors have been identified as very good candidates for environmental monitoring inside the silicon detectors operated at CERN’s Large Hadron Collider. In this study, we present the results from the first highly sensitive relative humidity distributed sensor with kilometres sensing ran...
Autores principales: | , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2019
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1117/12.2540007 http://cds.cern.ch/record/2834882 |
_version_ | 1780975617443889152 |
---|---|
author | Neves, Tiago F P Zhang, Li Yang, Fan Tow, Kenny H Petagna, Paolo Thévenaz, Luc |
author_facet | Neves, Tiago F P Zhang, Li Yang, Fan Tow, Kenny H Petagna, Paolo Thévenaz, Luc |
author_sort | Neves, Tiago F P |
collection | CERN |
description | Fibre optics sensors have been identified as very good candidates for environmental monitoring inside the silicon detectors operated at CERN’s Large Hadron Collider. In this study, we present the results from the first highly sensitive relative humidity distributed sensor with kilometres sensing range. The setup is a 70 cm spatial resolution phase-sensitive Optical Time Domain Reflectometry (OTDR) and is able to monitor fibre lengths up to 10 km. The coating effect is also evaluated, analysing different coating thicknesses, number of coating layers, different manufacturing and different materials. Relative humidity tests were performed at two different temperatures (25°C and 42°C). Polyimide coated fibres show in general a higher humidity sensitivity then a standard acrylate coated fibre, while acrylate fibres offer the fastest response and settling time. The system is able to resolve 0.1% RH and all tested fibres proved to be good candidates to be employed in a distributed relative humidity sensor. If the requirements are a fast time response and short settling time at room temperature, the standard acrylate coated fibres are the best candidates. However, if the requirements are high sensitivity and measurement stability at different temperatures, the polyimide-coated fibres offer advantages on several aspects. |
id | cern-2834882 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2019 |
record_format | invenio |
spelling | cern-28348822022-10-05T13:08:55Zdoi:10.1117/12.2540007http://cds.cern.ch/record/2834882engNeves, Tiago F PZhang, LiYang, FanTow, Kenny HPetagna, PaoloThévenaz, LucA kilometre-range distributed relative humidity sensorDetectors and Experimental TechniquesFibre optics sensors have been identified as very good candidates for environmental monitoring inside the silicon detectors operated at CERN’s Large Hadron Collider. In this study, we present the results from the first highly sensitive relative humidity distributed sensor with kilometres sensing range. The setup is a 70 cm spatial resolution phase-sensitive Optical Time Domain Reflectometry (OTDR) and is able to monitor fibre lengths up to 10 km. The coating effect is also evaluated, analysing different coating thicknesses, number of coating layers, different manufacturing and different materials. Relative humidity tests were performed at two different temperatures (25°C and 42°C). Polyimide coated fibres show in general a higher humidity sensitivity then a standard acrylate coated fibre, while acrylate fibres offer the fastest response and settling time. The system is able to resolve 0.1% RH and all tested fibres proved to be good candidates to be employed in a distributed relative humidity sensor. If the requirements are a fast time response and short settling time at room temperature, the standard acrylate coated fibres are the best candidates. However, if the requirements are high sensitivity and measurement stability at different temperatures, the polyimide-coated fibres offer advantages on several aspects.oai:cds.cern.ch:28348822019 |
spellingShingle | Detectors and Experimental Techniques Neves, Tiago F P Zhang, Li Yang, Fan Tow, Kenny H Petagna, Paolo Thévenaz, Luc A kilometre-range distributed relative humidity sensor |
title | A kilometre-range distributed relative humidity sensor |
title_full | A kilometre-range distributed relative humidity sensor |
title_fullStr | A kilometre-range distributed relative humidity sensor |
title_full_unstemmed | A kilometre-range distributed relative humidity sensor |
title_short | A kilometre-range distributed relative humidity sensor |
title_sort | kilometre-range distributed relative humidity sensor |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1117/12.2540007 http://cds.cern.ch/record/2834882 |
work_keys_str_mv | AT nevestiagofp akilometrerangedistributedrelativehumiditysensor AT zhangli akilometrerangedistributedrelativehumiditysensor AT yangfan akilometrerangedistributedrelativehumiditysensor AT towkennyh akilometrerangedistributedrelativehumiditysensor AT petagnapaolo akilometrerangedistributedrelativehumiditysensor AT thevenazluc akilometrerangedistributedrelativehumiditysensor AT nevestiagofp kilometrerangedistributedrelativehumiditysensor AT zhangli kilometrerangedistributedrelativehumiditysensor AT yangfan kilometrerangedistributedrelativehumiditysensor AT towkennyh kilometrerangedistributedrelativehumiditysensor AT petagnapaolo kilometrerangedistributedrelativehumiditysensor AT thevenazluc kilometrerangedistributedrelativehumiditysensor |