Cargando…

Intensity and bunch length measurement for lepton beam in the injection lines of the SPS and LEP

We describe a system which is used operationally to measure the absolute intensity of single lepton bunches in a beam transfer line. It is based on the detailed knowledge of every single item of a complex measuring chain that comprises a beam coupler on one end and an acquisition system on the other...

Descripción completa

Detalles Bibliográficos
Autores principales: Boccard, C, Bogey, T, Papis, J P, Vos, L
Lenguaje:eng
Publicado: 1995
Materias:
Acceso en línea:http://cds.cern.ch/record/283575
_version_ 1780888113731600384
author Boccard, C
Bogey, T
Papis, J P
Vos, L
author_facet Boccard, C
Bogey, T
Papis, J P
Vos, L
author_sort Boccard, C
collection CERN
description We describe a system which is used operationally to measure the absolute intensity of single lepton bunches in a beam transfer line. It is based on the detailed knowledge of every single item of a complex measuring chain that comprises a beam coupler on one end and an acquisition system on the other end. This knowledge can be acquired by a well tested theoretical model and careful measurement of the transfer function of each processing module. A precision better than 3 % can be obtained and no external calibration is required. A value for the bunch length can be deduced from a spectral intensity measurement at two well chosen frequencies.
id cern-283575
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 1995
record_format invenio
spelling cern-2835752023-05-05T12:57:18Zhttp://cds.cern.ch/record/283575engBoccard, CBogey, TPapis, J PVos, LIntensity and bunch length measurement for lepton beam in the injection lines of the SPS and LEPAccelerators and Storage RingsWe describe a system which is used operationally to measure the absolute intensity of single lepton bunches in a beam transfer line. It is based on the detailed knowledge of every single item of a complex measuring chain that comprises a beam coupler on one end and an acquisition system on the other end. This knowledge can be acquired by a well tested theoretical model and careful measurement of the transfer function of each processing module. A precision better than 3 % can be obtained and no external calibration is required. A value for the bunch length can be deduced from a spectral intensity measurement at two well chosen frequencies.CERN-SL-95-58-APoai:cds.cern.ch:2835751995-06-08
spellingShingle Accelerators and Storage Rings
Boccard, C
Bogey, T
Papis, J P
Vos, L
Intensity and bunch length measurement for lepton beam in the injection lines of the SPS and LEP
title Intensity and bunch length measurement for lepton beam in the injection lines of the SPS and LEP
title_full Intensity and bunch length measurement for lepton beam in the injection lines of the SPS and LEP
title_fullStr Intensity and bunch length measurement for lepton beam in the injection lines of the SPS and LEP
title_full_unstemmed Intensity and bunch length measurement for lepton beam in the injection lines of the SPS and LEP
title_short Intensity and bunch length measurement for lepton beam in the injection lines of the SPS and LEP
title_sort intensity and bunch length measurement for lepton beam in the injection lines of the sps and lep
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/283575
work_keys_str_mv AT boccardc intensityandbunchlengthmeasurementforleptonbeamintheinjectionlinesofthespsandlep
AT bogeyt intensityandbunchlengthmeasurementforleptonbeamintheinjectionlinesofthespsandlep
AT papisjp intensityandbunchlengthmeasurementforleptonbeamintheinjectionlinesofthespsandlep
AT vosl intensityandbunchlengthmeasurementforleptonbeamintheinjectionlinesofthespsandlep