Doppler and sympathetic cooling for the investigation of short-lived radioactive ions
At radioactive ion beam (RIB) facilities, ions of short-lived radionuclides are cooled and bunched in buffergas-filled Paul traps to improve the ion-beam quality for subsequent experiments. To deliver even colder ions, beneficial to RIB experiments’ sensitivity or accuracy, we employ Doppler and sym...
Autores principales: | , , , , , , , , , , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2022
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1103/PhysRevResearch.4.033229 http://cds.cern.ch/record/2836502 |
_version_ | 1780975750479872000 |
---|---|
author | Sels, S Maier, F M Au, M Fischer, P Kanitz, C Lagaki, V Lechner, S Leistenschneider, E Leimbach, D Lykiardopoulou, E M Kwiatkowski, A A Manovitz, T Vila Gracia, Y N Neyens, G Plattner, P Rothe, S Schweikhard, L Vilen, M Wolf, R N Malbrunot-Ettenauer, S |
author_facet | Sels, S Maier, F M Au, M Fischer, P Kanitz, C Lagaki, V Lechner, S Leistenschneider, E Leimbach, D Lykiardopoulou, E M Kwiatkowski, A A Manovitz, T Vila Gracia, Y N Neyens, G Plattner, P Rothe, S Schweikhard, L Vilen, M Wolf, R N Malbrunot-Ettenauer, S |
author_sort | Sels, S |
collection | CERN |
description | At radioactive ion beam (RIB) facilities, ions of short-lived radionuclides are cooled and bunched in buffergas-filled Paul traps to improve the ion-beam quality for subsequent experiments. To deliver even colder ions, beneficial to RIB experiments’ sensitivity or accuracy, we employ Doppler and sympathetic cooling in a Paul trap cooler-buncher. The improved emittance of Mg$^+$, K$^+$, and O$^+_2$ ion beams is demonstrated by a reduced time-of-flight spread of the extracted ion bunches with respect to room-temperature buffer-gas cooling. Cooling externally-produced hot ions with energies of at least 7 eV down to a few Kelvin is achieved in a timescale of $O$(100 ms) by combining a low-pressure helium background gas with laser cooling. This is sufficiently short to cool short-lived radioactive ions. As an example of this technique’s use for RIB research, the mass-resolving power in a multireflection time-of-flight mass spectrometer is shown to increase by up to a factor of 4.6 with respect to buffer-gas cooling. Simulations show good agreement with the experimental results and guide further improvements and applications. These results open a path to a significant emittance improvement and, thus, unprecedented ion-beam qualities at RIB facilities, achievable with standard equipment readily available. The same method provides opportunities for future high-precision experiments with radioactive cold trapped ions. |
id | cern-2836502 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2022 |
record_format | invenio |
spelling | cern-28365022023-03-30T15:54:16Zdoi:10.1103/PhysRevResearch.4.033229http://cds.cern.ch/record/2836502engSels, SMaier, F MAu, MFischer, PKanitz, CLagaki, VLechner, SLeistenschneider, ELeimbach, DLykiardopoulou, E MKwiatkowski, A AManovitz, TVila Gracia, Y NNeyens, GPlattner, PRothe, SSchweikhard, LVilen, MWolf, R NMalbrunot-Ettenauer, SDoppler and sympathetic cooling for the investigation of short-lived radioactive ionsAccelerators and Storage RingsAt radioactive ion beam (RIB) facilities, ions of short-lived radionuclides are cooled and bunched in buffergas-filled Paul traps to improve the ion-beam quality for subsequent experiments. To deliver even colder ions, beneficial to RIB experiments’ sensitivity or accuracy, we employ Doppler and sympathetic cooling in a Paul trap cooler-buncher. The improved emittance of Mg$^+$, K$^+$, and O$^+_2$ ion beams is demonstrated by a reduced time-of-flight spread of the extracted ion bunches with respect to room-temperature buffer-gas cooling. Cooling externally-produced hot ions with energies of at least 7 eV down to a few Kelvin is achieved in a timescale of $O$(100 ms) by combining a low-pressure helium background gas with laser cooling. This is sufficiently short to cool short-lived radioactive ions. As an example of this technique’s use for RIB research, the mass-resolving power in a multireflection time-of-flight mass spectrometer is shown to increase by up to a factor of 4.6 with respect to buffer-gas cooling. Simulations show good agreement with the experimental results and guide further improvements and applications. These results open a path to a significant emittance improvement and, thus, unprecedented ion-beam qualities at RIB facilities, achievable with standard equipment readily available. The same method provides opportunities for future high-precision experiments with radioactive cold trapped ions.oai:cds.cern.ch:28365022022 |
spellingShingle | Accelerators and Storage Rings Sels, S Maier, F M Au, M Fischer, P Kanitz, C Lagaki, V Lechner, S Leistenschneider, E Leimbach, D Lykiardopoulou, E M Kwiatkowski, A A Manovitz, T Vila Gracia, Y N Neyens, G Plattner, P Rothe, S Schweikhard, L Vilen, M Wolf, R N Malbrunot-Ettenauer, S Doppler and sympathetic cooling for the investigation of short-lived radioactive ions |
title | Doppler and sympathetic cooling for the investigation of short-lived radioactive ions |
title_full | Doppler and sympathetic cooling for the investigation of short-lived radioactive ions |
title_fullStr | Doppler and sympathetic cooling for the investigation of short-lived radioactive ions |
title_full_unstemmed | Doppler and sympathetic cooling for the investigation of short-lived radioactive ions |
title_short | Doppler and sympathetic cooling for the investigation of short-lived radioactive ions |
title_sort | doppler and sympathetic cooling for the investigation of short-lived radioactive ions |
topic | Accelerators and Storage Rings |
url | https://dx.doi.org/10.1103/PhysRevResearch.4.033229 http://cds.cern.ch/record/2836502 |
work_keys_str_mv | AT selss dopplerandsympatheticcoolingfortheinvestigationofshortlivedradioactiveions AT maierfm dopplerandsympatheticcoolingfortheinvestigationofshortlivedradioactiveions AT aum dopplerandsympatheticcoolingfortheinvestigationofshortlivedradioactiveions AT fischerp dopplerandsympatheticcoolingfortheinvestigationofshortlivedradioactiveions AT kanitzc dopplerandsympatheticcoolingfortheinvestigationofshortlivedradioactiveions AT lagakiv dopplerandsympatheticcoolingfortheinvestigationofshortlivedradioactiveions AT lechners dopplerandsympatheticcoolingfortheinvestigationofshortlivedradioactiveions AT leistenschneidere dopplerandsympatheticcoolingfortheinvestigationofshortlivedradioactiveions AT leimbachd dopplerandsympatheticcoolingfortheinvestigationofshortlivedradioactiveions AT lykiardopoulouem dopplerandsympatheticcoolingfortheinvestigationofshortlivedradioactiveions AT kwiatkowskiaa dopplerandsympatheticcoolingfortheinvestigationofshortlivedradioactiveions AT manovitzt dopplerandsympatheticcoolingfortheinvestigationofshortlivedradioactiveions AT vilagraciayn dopplerandsympatheticcoolingfortheinvestigationofshortlivedradioactiveions AT neyensg dopplerandsympatheticcoolingfortheinvestigationofshortlivedradioactiveions AT plattnerp dopplerandsympatheticcoolingfortheinvestigationofshortlivedradioactiveions AT rothes dopplerandsympatheticcoolingfortheinvestigationofshortlivedradioactiveions AT schweikhardl dopplerandsympatheticcoolingfortheinvestigationofshortlivedradioactiveions AT vilenm dopplerandsympatheticcoolingfortheinvestigationofshortlivedradioactiveions AT wolfrn dopplerandsympatheticcoolingfortheinvestigationofshortlivedradioactiveions AT malbrunotettenauers dopplerandsympatheticcoolingfortheinvestigationofshortlivedradioactiveions |