Reduction of high voltage discharge in GEM detectors for the ME0 station of the CMS forward muon system

The Phase 2 upgrade of the CMS muon spectrometer will include the installation of two new muon stations based on Gas Electron Multiplier (GEM) technology. While the GE1/1 station is already installed and the GE2/1 detectors are under construction, the ME0 station is expected to be inserted in CMS du...

Descripción completa

Detalles Bibliográficos
Autores principales: Mohamed, Salwa, Elkafrawy, Tamer, Merlin, Jeremie Alexandre
Lenguaje:eng
Publicado: 2022
Materias:
Acceso en línea:http://cds.cern.ch/record/2839750
_version_ 1780975982010695680
author Mohamed, Salwa
Elkafrawy, Tamer
Merlin, Jeremie Alexandre
author_facet Mohamed, Salwa
Elkafrawy, Tamer
Merlin, Jeremie Alexandre
author_sort Mohamed, Salwa
collection CERN
description The Phase 2 upgrade of the CMS muon spectrometer will include the installation of two new muon stations based on Gas Electron Multiplier (GEM) technology. While the GE1/1 station is already installed and the GE2/1 detectors are under construction, the ME0 station is expected to be inserted in CMS during the Long Shutdown 3 (LS3). The new ME0 system will increase the acceptance for muon detection in the region $2.03<\eta<2.82$ where there is a high radiation background. When triple-GEM detectors, including ME0, operate at high gain, there are occasional discharges within the transfer gaps that are likely followed by less-common secondary discharges and may cause irreversible damage to the detector. The ME0 detector has the advantage of using double-segmented GEM foils that help lower the probability of high voltage discharges, and in turn, this protects the detector and maintains the high detection efficiency. To optimize the ME0 design, we studied the impact of High Voltage (HV) filter resistors and segment orientation of ME0 GEM foils on discharge propagation probability within the detector.
id cern-2839750
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2022
record_format invenio
spelling cern-28397502022-11-07T21:59:39Zhttp://cds.cern.ch/record/2839750engMohamed, SalwaElkafrawy, TamerMerlin, Jeremie AlexandreReduction of high voltage discharge in GEM detectors for the ME0 station of the CMS forward muon systemDetectors and Experimental TechniquesThe Phase 2 upgrade of the CMS muon spectrometer will include the installation of two new muon stations based on Gas Electron Multiplier (GEM) technology. While the GE1/1 station is already installed and the GE2/1 detectors are under construction, the ME0 station is expected to be inserted in CMS during the Long Shutdown 3 (LS3). The new ME0 system will increase the acceptance for muon detection in the region $2.03<\eta<2.82$ where there is a high radiation background. When triple-GEM detectors, including ME0, operate at high gain, there are occasional discharges within the transfer gaps that are likely followed by less-common secondary discharges and may cause irreversible damage to the detector. The ME0 detector has the advantage of using double-segmented GEM foils that help lower the probability of high voltage discharges, and in turn, this protects the detector and maintains the high detection efficiency. To optimize the ME0 design, we studied the impact of High Voltage (HV) filter resistors and segment orientation of ME0 GEM foils on discharge propagation probability within the detector.CMS-CR-2022-143oai:cds.cern.ch:28397502022-09-06
spellingShingle Detectors and Experimental Techniques
Mohamed, Salwa
Elkafrawy, Tamer
Merlin, Jeremie Alexandre
Reduction of high voltage discharge in GEM detectors for the ME0 station of the CMS forward muon system
title Reduction of high voltage discharge in GEM detectors for the ME0 station of the CMS forward muon system
title_full Reduction of high voltage discharge in GEM detectors for the ME0 station of the CMS forward muon system
title_fullStr Reduction of high voltage discharge in GEM detectors for the ME0 station of the CMS forward muon system
title_full_unstemmed Reduction of high voltage discharge in GEM detectors for the ME0 station of the CMS forward muon system
title_short Reduction of high voltage discharge in GEM detectors for the ME0 station of the CMS forward muon system
title_sort reduction of high voltage discharge in gem detectors for the me0 station of the cms forward muon system
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/2839750
work_keys_str_mv AT mohamedsalwa reductionofhighvoltagedischargeingemdetectorsfortheme0stationofthecmsforwardmuonsystem
AT elkafrawytamer reductionofhighvoltagedischargeingemdetectorsfortheme0stationofthecmsforwardmuonsystem
AT merlinjeremiealexandre reductionofhighvoltagedischargeingemdetectorsfortheme0stationofthecmsforwardmuonsystem