Transient Heat Transfer to Confined Superfluid Helium

To investigate how the Large Hadron Collider at CERN can survive UFO attacks much larger than expected, we build and perform an experiment designed to measure the transient temperature evolution of both a stainless steel heater subjected to millisecond time-scale losses and the confined helium cooli...

Descripción completa

Detalles Bibliográficos
Autor principal: Ghini, Jonas Blomberg
Lenguaje:eng
Publicado: 2022
Materias:
Acceso en línea:http://cds.cern.ch/record/2841044
_version_ 1780976160945995776
author Ghini, Jonas Blomberg
author_facet Ghini, Jonas Blomberg
author_sort Ghini, Jonas Blomberg
collection CERN
description To investigate how the Large Hadron Collider at CERN can survive UFO attacks much larger than expected, we build and perform an experiment designed to measure the transient temperature evolution of both a stainless steel heater subjected to millisecond time-scale losses and the confined helium cooling this heater. In the first paper we focus on a configuration where the heater is cooled by an open bath of superfluid helium. Setup validation is done by fitting the Kapitza heat transfer expression to steady state measurements, finding fit parameters within the expected range. We do not find conclusive evidence of an orientation dependence of the Kapitza heat transfer mechanism, nor heat transfer differences that can be attributed to local surface variations along the same heater. The setup shows critical heat flux in line with estimates from literature, and the time between a step in heating and the onset of film boiling follows the expected behaviour. During the first millisecond after a step in applied heating power density our measurements show a slower thermal rise time than that found by a time-dependent one-dimensional model of our setup using the steady state Kapitza heat transfer expression as the cooling boundary condition. After the first millisecond, agreement between measurement and model is excellent. In the second paper we confine the helium near the heater to a channel of 120 μm depth. The helium is isolated from the external bath with the exception of two pin-holes that, on the time-scale of tens of milliseconds, allow only negligible heat exchange with the external bath. We measure the temperatures of both the heater strip and the channel helium during slow-pulse heating that reaches peak power after 9 ms, fast-pulse heating that reaches peak power after 100 μs, and step heating that reaches steady power after 100 μs. Using the steady state Kapitza heat transfer expression at the interface between heater and helium, and the Gorter-Mellink heat transfer regime in the helium channel, we obtain excellent agreement between simulation and measurement during the first 5 ms of slow-pulse tests. Using instead the measured helium temperature in the Kapitza expression, we obtain excellent agreement between the simulated and measured heater response during the first 150 ms of slow-pulse tests. The same model fails to explain the fast-pulse transient response of the heater and helium, while it can only explain the helium response to a step in applied power. The steady state Kapitza expression may therefore not be applicable to heating events that are over within a single millisecond.
id cern-2841044
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2022
record_format invenio
spelling cern-28410442023-03-09T13:51:14Zhttp://cds.cern.ch/record/2841044engGhini, Jonas BlombergTransient Heat Transfer to Confined Superfluid HeliumOtherTo investigate how the Large Hadron Collider at CERN can survive UFO attacks much larger than expected, we build and perform an experiment designed to measure the transient temperature evolution of both a stainless steel heater subjected to millisecond time-scale losses and the confined helium cooling this heater. In the first paper we focus on a configuration where the heater is cooled by an open bath of superfluid helium. Setup validation is done by fitting the Kapitza heat transfer expression to steady state measurements, finding fit parameters within the expected range. We do not find conclusive evidence of an orientation dependence of the Kapitza heat transfer mechanism, nor heat transfer differences that can be attributed to local surface variations along the same heater. The setup shows critical heat flux in line with estimates from literature, and the time between a step in heating and the onset of film boiling follows the expected behaviour. During the first millisecond after a step in applied heating power density our measurements show a slower thermal rise time than that found by a time-dependent one-dimensional model of our setup using the steady state Kapitza heat transfer expression as the cooling boundary condition. After the first millisecond, agreement between measurement and model is excellent. In the second paper we confine the helium near the heater to a channel of 120 μm depth. The helium is isolated from the external bath with the exception of two pin-holes that, on the time-scale of tens of milliseconds, allow only negligible heat exchange with the external bath. We measure the temperatures of both the heater strip and the channel helium during slow-pulse heating that reaches peak power after 9 ms, fast-pulse heating that reaches peak power after 100 μs, and step heating that reaches steady power after 100 μs. Using the steady state Kapitza heat transfer expression at the interface between heater and helium, and the Gorter-Mellink heat transfer regime in the helium channel, we obtain excellent agreement between simulation and measurement during the first 5 ms of slow-pulse tests. Using instead the measured helium temperature in the Kapitza expression, we obtain excellent agreement between the simulated and measured heater response during the first 150 ms of slow-pulse tests. The same model fails to explain the fast-pulse transient response of the heater and helium, while it can only explain the helium response to a step in applied power. The steady state Kapitza expression may therefore not be applicable to heating events that are over within a single millisecond.oai:cds.cern.ch:28410442022
spellingShingle Other
Ghini, Jonas Blomberg
Transient Heat Transfer to Confined Superfluid Helium
title Transient Heat Transfer to Confined Superfluid Helium
title_full Transient Heat Transfer to Confined Superfluid Helium
title_fullStr Transient Heat Transfer to Confined Superfluid Helium
title_full_unstemmed Transient Heat Transfer to Confined Superfluid Helium
title_short Transient Heat Transfer to Confined Superfluid Helium
title_sort transient heat transfer to confined superfluid helium
topic Other
url http://cds.cern.ch/record/2841044
work_keys_str_mv AT ghinijonasblomberg transientheattransfertoconfinedsuperfluidhelium