Failure analysis of a heavy gauge fastener of the ITER toroidal field gravity support system
The Gravity Supports (GS) of the ITER Toroidal Field (TF) coils are positioned at the bottom of the machine and are situated under the 18 toroidal field coils. Each support includes 26 high strength bolts with M60 and M85 gauge. The TFGS will sustain a total load of about 11,000 tonnes of dead weigh...