Cargando…
Automated Design and Optimization of the Final Cooling for a Muon Collider
The desired beam emittance for a Muon collider is several orders of magnitude less than the one of the muon beams produced at the front-end target. Ionization cooling has been demonstrated as a suitable technique for the reduction of the muon beam emittance. Final cooling, as one of the most critica...
Autores principales: | , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2022
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.18429/JACoW-IPAC2022-WEPOMS047 http://cds.cern.ch/record/2845865 |
Sumario: | The desired beam emittance for a Muon collider is several orders of magnitude less than the one of the muon beams produced at the front-end target. Ionization cooling has been demonstrated as a suitable technique for the reduction of the muon beam emittance. Final cooling, as one of the most critical stages of the muon collider complex, necessitates careful design and optimization in order to control the beam dynamics and ensure efficient emittance reduction. We present an optimization framework based on ICool simulation code and application of different optimization algorithms, to automatize the choice of optimal initial muon beam parameters and simultaneous tuning of numerous final cooling components. |
---|