Cargando…
Numerical Calibration of the Bead-Pull Setup for Beam Coupling Impedance Evaluation
The bead-pull method is a commonly used electromagnetic field measurement technique exploited to tune a radiofrequency cavity to achieve design specifications. The frequency of a resonant cavity is perturbed by inserting a metallic or dielectric bead. For a given electromagnetic field, the amplitude...
Autores principales: | , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2022
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.18429/JACoW-IPAC2022-MOPOTK062 http://cds.cern.ch/record/2845868 |
_version_ | 1780976595656245248 |
---|---|
author | El Dali, Dalia Mahmoud Fouda De Michele, Giovanni Fanella, Stefano Métral, Elias Zannini, Carlo |
author_facet | El Dali, Dalia Mahmoud Fouda De Michele, Giovanni Fanella, Stefano Métral, Elias Zannini, Carlo |
author_sort | El Dali, Dalia Mahmoud Fouda |
collection | CERN |
description | The bead-pull method is a commonly used electromagnetic field measurement technique exploited to tune a radiofrequency cavity to achieve design specifications. The frequency of a resonant cavity is perturbed by inserting a metallic or dielectric bead. For a given electromagnetic field, the amplitude of the perturbation depends only on the geometry of the perturbing object. Therefore, the calibration of the bead can be done in different resonant structures without loss of generality. In this paper, a method to perform an accurate calibration of the bead with electromagnetic simulations is proposed. Compared to the common practice of measuring a reference cavity, the flexibility given by the simulation method to study different bead shapes and sizes could be advantageous to optimize the measurement setup. A calibrated bead-pull setup allows to quantify the electric field and, therefore, the shunt impedance of the resonant modes of the cavity. As experimental benchmark, the beam coupling impedance measured with the calibrated bead-pull setup is compared with electromagnetic simulations. |
id | cern-2845868 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2022 |
record_format | invenio |
spelling | cern-28458682023-01-11T21:31:27Zdoi:10.18429/JACoW-IPAC2022-MOPOTK062http://cds.cern.ch/record/2845868engEl Dali, Dalia Mahmoud FoudaDe Michele, GiovanniFanella, StefanoMétral, EliasZannini, CarloNumerical Calibration of the Bead-Pull Setup for Beam Coupling Impedance EvaluationAccelerators and Storage RingsThe bead-pull method is a commonly used electromagnetic field measurement technique exploited to tune a radiofrequency cavity to achieve design specifications. The frequency of a resonant cavity is perturbed by inserting a metallic or dielectric bead. For a given electromagnetic field, the amplitude of the perturbation depends only on the geometry of the perturbing object. Therefore, the calibration of the bead can be done in different resonant structures without loss of generality. In this paper, a method to perform an accurate calibration of the bead with electromagnetic simulations is proposed. Compared to the common practice of measuring a reference cavity, the flexibility given by the simulation method to study different bead shapes and sizes could be advantageous to optimize the measurement setup. A calibrated bead-pull setup allows to quantify the electric field and, therefore, the shunt impedance of the resonant modes of the cavity. As experimental benchmark, the beam coupling impedance measured with the calibrated bead-pull setup is compared with electromagnetic simulations.oai:cds.cern.ch:28458682022 |
spellingShingle | Accelerators and Storage Rings El Dali, Dalia Mahmoud Fouda De Michele, Giovanni Fanella, Stefano Métral, Elias Zannini, Carlo Numerical Calibration of the Bead-Pull Setup for Beam Coupling Impedance Evaluation |
title | Numerical Calibration of the Bead-Pull Setup for Beam Coupling Impedance Evaluation |
title_full | Numerical Calibration of the Bead-Pull Setup for Beam Coupling Impedance Evaluation |
title_fullStr | Numerical Calibration of the Bead-Pull Setup for Beam Coupling Impedance Evaluation |
title_full_unstemmed | Numerical Calibration of the Bead-Pull Setup for Beam Coupling Impedance Evaluation |
title_short | Numerical Calibration of the Bead-Pull Setup for Beam Coupling Impedance Evaluation |
title_sort | numerical calibration of the bead-pull setup for beam coupling impedance evaluation |
topic | Accelerators and Storage Rings |
url | https://dx.doi.org/10.18429/JACoW-IPAC2022-MOPOTK062 http://cds.cern.ch/record/2845868 |
work_keys_str_mv | AT eldalidaliamahmoudfouda numericalcalibrationofthebeadpullsetupforbeamcouplingimpedanceevaluation AT demichelegiovanni numericalcalibrationofthebeadpullsetupforbeamcouplingimpedanceevaluation AT fanellastefano numericalcalibrationofthebeadpullsetupforbeamcouplingimpedanceevaluation AT metralelias numericalcalibrationofthebeadpullsetupforbeamcouplingimpedanceevaluation AT zanninicarlo numericalcalibrationofthebeadpullsetupforbeamcouplingimpedanceevaluation |