Cargando…

Numerical Calibration of the Bead-Pull Setup for Beam Coupling Impedance Evaluation

The bead-pull method is a commonly used electromagnetic field measurement technique exploited to tune a radiofrequency cavity to achieve design specifications. The frequency of a resonant cavity is perturbed by inserting a metallic or dielectric bead. For a given electromagnetic field, the amplitude...

Descripción completa

Detalles Bibliográficos
Autores principales: El Dali, Dalia Mahmoud Fouda, De Michele, Giovanni, Fanella, Stefano, Métral, Elias, Zannini, Carlo
Lenguaje:eng
Publicado: 2022
Materias:
Acceso en línea:https://dx.doi.org/10.18429/JACoW-IPAC2022-MOPOTK062
http://cds.cern.ch/record/2845868
_version_ 1780976595656245248
author El Dali, Dalia Mahmoud Fouda
De Michele, Giovanni
Fanella, Stefano
Métral, Elias
Zannini, Carlo
author_facet El Dali, Dalia Mahmoud Fouda
De Michele, Giovanni
Fanella, Stefano
Métral, Elias
Zannini, Carlo
author_sort El Dali, Dalia Mahmoud Fouda
collection CERN
description The bead-pull method is a commonly used electromagnetic field measurement technique exploited to tune a radiofrequency cavity to achieve design specifications. The frequency of a resonant cavity is perturbed by inserting a metallic or dielectric bead. For a given electromagnetic field, the amplitude of the perturbation depends only on the geometry of the perturbing object. Therefore, the calibration of the bead can be done in different resonant structures without loss of generality. In this paper, a method to perform an accurate calibration of the bead with electromagnetic simulations is proposed. Compared to the common practice of measuring a reference cavity, the flexibility given by the simulation method to study different bead shapes and sizes could be advantageous to optimize the measurement setup. A calibrated bead-pull setup allows to quantify the electric field and, therefore, the shunt impedance of the resonant modes of the cavity. As experimental benchmark, the beam coupling impedance measured with the calibrated bead-pull setup is compared with electromagnetic simulations.
id cern-2845868
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2022
record_format invenio
spelling cern-28458682023-01-11T21:31:27Zdoi:10.18429/JACoW-IPAC2022-MOPOTK062http://cds.cern.ch/record/2845868engEl Dali, Dalia Mahmoud FoudaDe Michele, GiovanniFanella, StefanoMétral, EliasZannini, CarloNumerical Calibration of the Bead-Pull Setup for Beam Coupling Impedance EvaluationAccelerators and Storage RingsThe bead-pull method is a commonly used electromagnetic field measurement technique exploited to tune a radiofrequency cavity to achieve design specifications. The frequency of a resonant cavity is perturbed by inserting a metallic or dielectric bead. For a given electromagnetic field, the amplitude of the perturbation depends only on the geometry of the perturbing object. Therefore, the calibration of the bead can be done in different resonant structures without loss of generality. In this paper, a method to perform an accurate calibration of the bead with electromagnetic simulations is proposed. Compared to the common practice of measuring a reference cavity, the flexibility given by the simulation method to study different bead shapes and sizes could be advantageous to optimize the measurement setup. A calibrated bead-pull setup allows to quantify the electric field and, therefore, the shunt impedance of the resonant modes of the cavity. As experimental benchmark, the beam coupling impedance measured with the calibrated bead-pull setup is compared with electromagnetic simulations.oai:cds.cern.ch:28458682022
spellingShingle Accelerators and Storage Rings
El Dali, Dalia Mahmoud Fouda
De Michele, Giovanni
Fanella, Stefano
Métral, Elias
Zannini, Carlo
Numerical Calibration of the Bead-Pull Setup for Beam Coupling Impedance Evaluation
title Numerical Calibration of the Bead-Pull Setup for Beam Coupling Impedance Evaluation
title_full Numerical Calibration of the Bead-Pull Setup for Beam Coupling Impedance Evaluation
title_fullStr Numerical Calibration of the Bead-Pull Setup for Beam Coupling Impedance Evaluation
title_full_unstemmed Numerical Calibration of the Bead-Pull Setup for Beam Coupling Impedance Evaluation
title_short Numerical Calibration of the Bead-Pull Setup for Beam Coupling Impedance Evaluation
title_sort numerical calibration of the bead-pull setup for beam coupling impedance evaluation
topic Accelerators and Storage Rings
url https://dx.doi.org/10.18429/JACoW-IPAC2022-MOPOTK062
http://cds.cern.ch/record/2845868
work_keys_str_mv AT eldalidaliamahmoudfouda numericalcalibrationofthebeadpullsetupforbeamcouplingimpedanceevaluation
AT demichelegiovanni numericalcalibrationofthebeadpullsetupforbeamcouplingimpedanceevaluation
AT fanellastefano numericalcalibrationofthebeadpullsetupforbeamcouplingimpedanceevaluation
AT metralelias numericalcalibrationofthebeadpullsetupforbeamcouplingimpedanceevaluation