Degradation and Recovery of the LHC RF Cryomodule Performance Using the Helium Processing Technique
The LHC RF cryomodule "Asia" suffered an accidental influx of about 0.5 l of tunnel air during the leak checks of the pumping manifolds. The resulting risk of particle contamination was difficult to assess, and could not be excluded with certainty. If one or more cavities were contaminated...
Autores principales: | Turaj, Katarzyna, Brunner, Olivier, Butterworth, Andrew, Gerigk, Frank, Maesen, Pierre, Montesinos, Eric, Peauger, Franck, Therasse, Mathieu, Venturini Delsolaro, Walter |
---|---|
Lenguaje: | eng |
Publicado: |
2022
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.18429/JACoW-SRF2021-THPFAV006 http://cds.cern.ch/record/2846167 |