Cargando…
Performance of the Cable-in-Conduit Conductors for Super-X Test Facility
Following the conceptual design, the engineering design of the dc magnet and cable-in-conduit conductor (CICC) for the Super-X test facility has been done in 2021. Totally three types of conductors with different structures were designed for the three pairs of coils in the dc magnet, respectively. H...
Autores principales: | , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2023
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1109/TASC.2022.3224589 http://cds.cern.ch/record/2847606 |
_version_ | 1780976804690919424 |
---|---|
author | Dai, Chao Wu, Yu Shi, Yi Sedlak, Kamil Bajas, Hugo Nijuis, Arend Hao, Qiangwang Han, Houxiang Liu, YunHao Devred, Arnaud Qin, Jinggang |
author_facet | Dai, Chao Wu, Yu Shi, Yi Sedlak, Kamil Bajas, Hugo Nijuis, Arend Hao, Qiangwang Han, Houxiang Liu, YunHao Devred, Arnaud Qin, Jinggang |
author_sort | Dai, Chao |
collection | CERN |
description | Following the conceptual design, the engineering design of the dc magnet and cable-in-conduit conductor (CICC) for the Super-X test facility has been done in 2021. Totally three types of conductors with different structures were designed for the three pairs of coils in the dc magnet, respectively. High-
Jc
Nb
3
Sn strand (J
c
∼2200 A/mm
2
at 12 T, 4.2 K) was applied to high field and middle field coils for reducing the radius of the dc magnet. In order to qualify if the designed parameters of the conductors could fulfill the performance criteria, three pairs of short samples have been manufactured and tested successfully in the SULTAN facility at SPC, Switzerland. Test results and analysis show that dc performance of the three types of conductors can meet the design criteria. The conductor qualification process including the sample preparation, test results, and analysis are presented in this article. The HFC and LFC conductors exhibit different ac loss behavior to the MFC conductor, which is discussed in the article. |
id | cern-2847606 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2023 |
record_format | invenio |
spelling | cern-28476062023-01-26T23:07:09Zdoi:10.1109/TASC.2022.3224589http://cds.cern.ch/record/2847606engDai, ChaoWu, YuShi, YiSedlak, KamilBajas, HugoNijuis, ArendHao, QiangwangHan, HouxiangLiu, YunHaoDevred, ArnaudQin, JinggangPerformance of the Cable-in-Conduit Conductors for Super-X Test FacilityAccelerators and Storage RingsFollowing the conceptual design, the engineering design of the dc magnet and cable-in-conduit conductor (CICC) for the Super-X test facility has been done in 2021. Totally three types of conductors with different structures were designed for the three pairs of coils in the dc magnet, respectively. High- Jc Nb 3 Sn strand (J c ∼2200 A/mm 2 at 12 T, 4.2 K) was applied to high field and middle field coils for reducing the radius of the dc magnet. In order to qualify if the designed parameters of the conductors could fulfill the performance criteria, three pairs of short samples have been manufactured and tested successfully in the SULTAN facility at SPC, Switzerland. Test results and analysis show that dc performance of the three types of conductors can meet the design criteria. The conductor qualification process including the sample preparation, test results, and analysis are presented in this article. The HFC and LFC conductors exhibit different ac loss behavior to the MFC conductor, which is discussed in the article.oai:cds.cern.ch:28476062023 |
spellingShingle | Accelerators and Storage Rings Dai, Chao Wu, Yu Shi, Yi Sedlak, Kamil Bajas, Hugo Nijuis, Arend Hao, Qiangwang Han, Houxiang Liu, YunHao Devred, Arnaud Qin, Jinggang Performance of the Cable-in-Conduit Conductors for Super-X Test Facility |
title | Performance of the Cable-in-Conduit Conductors for Super-X Test Facility |
title_full | Performance of the Cable-in-Conduit Conductors for Super-X Test Facility |
title_fullStr | Performance of the Cable-in-Conduit Conductors for Super-X Test Facility |
title_full_unstemmed | Performance of the Cable-in-Conduit Conductors for Super-X Test Facility |
title_short | Performance of the Cable-in-Conduit Conductors for Super-X Test Facility |
title_sort | performance of the cable-in-conduit conductors for super-x test facility |
topic | Accelerators and Storage Rings |
url | https://dx.doi.org/10.1109/TASC.2022.3224589 http://cds.cern.ch/record/2847606 |
work_keys_str_mv | AT daichao performanceofthecableinconduitconductorsforsuperxtestfacility AT wuyu performanceofthecableinconduitconductorsforsuperxtestfacility AT shiyi performanceofthecableinconduitconductorsforsuperxtestfacility AT sedlakkamil performanceofthecableinconduitconductorsforsuperxtestfacility AT bajashugo performanceofthecableinconduitconductorsforsuperxtestfacility AT nijuisarend performanceofthecableinconduitconductorsforsuperxtestfacility AT haoqiangwang performanceofthecableinconduitconductorsforsuperxtestfacility AT hanhouxiang performanceofthecableinconduitconductorsforsuperxtestfacility AT liuyunhao performanceofthecableinconduitconductorsforsuperxtestfacility AT devredarnaud performanceofthecableinconduitconductorsforsuperxtestfacility AT qinjinggang performanceofthecableinconduitconductorsforsuperxtestfacility |