Cargando…

Simulation studies of a 30-keV MR-ToF device for highly sensitive collinear laser spectroscopy

The Multi Ion Reflection Apparatus for Collinear Laser Spectroscopy (MIRACLS) seeks to extend the reach of high-resolution collinear laser spectroscopy (CLS) to more exotic radionuclides. In this novel technique, ion bunches of short-lived radioisotopes are trapped between two electrostatic mirrors...

Descripción completa

Detalles Bibliográficos
Autores principales: Maier, F M, Vilen, M, Belosevic, I, Buchinger, F, Kanitz, C, Lechner, S, Leistenschneider, E, Nörtershäuser, W, Plattner, P, Schweikhard, L, Sels, S, Wienholtz, F, Malbrunot-Ettenauer, S
Lenguaje:eng
Publicado: 2023
Materias:
Acceso en línea:https://dx.doi.org/10.1016/j.nima.2022.167927
http://cds.cern.ch/record/2847616
_version_ 1780976806946406400
author Maier, F M
Vilen, M
Belosevic, I
Buchinger, F
Kanitz, C
Lechner, S
Leistenschneider, E
Nörtershäuser, W
Plattner, P
Schweikhard, L
Sels, S
Wienholtz, F
Malbrunot-Ettenauer, S
author_facet Maier, F M
Vilen, M
Belosevic, I
Buchinger, F
Kanitz, C
Lechner, S
Leistenschneider, E
Nörtershäuser, W
Plattner, P
Schweikhard, L
Sels, S
Wienholtz, F
Malbrunot-Ettenauer, S
author_sort Maier, F M
collection CERN
description The Multi Ion Reflection Apparatus for Collinear Laser Spectroscopy (MIRACLS) seeks to extend the reach of high-resolution collinear laser spectroscopy (CLS) to more exotic radionuclides. In this novel technique, ion bunches of short-lived radioisotopes are trapped between two electrostatic mirrors of a Multi-Reflection Time-of-Flight (MR-ToF) device at 30-keV kinetic energy. The same ion bunch can be probed by a spectroscopy laser for thousands of times compared to a single probing in the traditional CLS measurement scheme. Thus, the experimental sensitivity is increased by more than one to two orders of magnitude. Extensive simulations are presented, demonstrating the feasibility of high-resolution collinear laser spectroscopy (CLS) in the newly envisioned MR-ToF apparatus operating at ion energies of 30 keV. Once the mechanical design and operational parameters are optimized for the requirements of CLS, the spectral line is neither significantly broadened nor distorted by the combination of CLS and MR-ToF operation. According to the simulations, the storage efficiency and the ion–laser overlap are suitable for laser excitation of the majority of the trapped ions. In summary, >90% injection and storage efficiency, >75% ion–laser overlap and a line width approaching the natural line width of the transition of interest are reached in the simulation.
id cern-2847616
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2023
record_format invenio
spelling cern-28476162023-03-28T14:06:01Zdoi:10.1016/j.nima.2022.167927http://cds.cern.ch/record/2847616engMaier, F MVilen, MBelosevic, IBuchinger, FKanitz, CLechner, SLeistenschneider, ENörtershäuser, WPlattner, PSchweikhard, LSels, SWienholtz, FMalbrunot-Ettenauer, SSimulation studies of a 30-keV MR-ToF device for highly sensitive collinear laser spectroscopyDetectors and Experimental TechniquesThe Multi Ion Reflection Apparatus for Collinear Laser Spectroscopy (MIRACLS) seeks to extend the reach of high-resolution collinear laser spectroscopy (CLS) to more exotic radionuclides. In this novel technique, ion bunches of short-lived radioisotopes are trapped between two electrostatic mirrors of a Multi-Reflection Time-of-Flight (MR-ToF) device at 30-keV kinetic energy. The same ion bunch can be probed by a spectroscopy laser for thousands of times compared to a single probing in the traditional CLS measurement scheme. Thus, the experimental sensitivity is increased by more than one to two orders of magnitude. Extensive simulations are presented, demonstrating the feasibility of high-resolution collinear laser spectroscopy (CLS) in the newly envisioned MR-ToF apparatus operating at ion energies of 30 keV. Once the mechanical design and operational parameters are optimized for the requirements of CLS, the spectral line is neither significantly broadened nor distorted by the combination of CLS and MR-ToF operation. According to the simulations, the storage efficiency and the ion–laser overlap are suitable for laser excitation of the majority of the trapped ions. In summary, >90% injection and storage efficiency, >75% ion–laser overlap and a line width approaching the natural line width of the transition of interest are reached in the simulation.oai:cds.cern.ch:28476162023
spellingShingle Detectors and Experimental Techniques
Maier, F M
Vilen, M
Belosevic, I
Buchinger, F
Kanitz, C
Lechner, S
Leistenschneider, E
Nörtershäuser, W
Plattner, P
Schweikhard, L
Sels, S
Wienholtz, F
Malbrunot-Ettenauer, S
Simulation studies of a 30-keV MR-ToF device for highly sensitive collinear laser spectroscopy
title Simulation studies of a 30-keV MR-ToF device for highly sensitive collinear laser spectroscopy
title_full Simulation studies of a 30-keV MR-ToF device for highly sensitive collinear laser spectroscopy
title_fullStr Simulation studies of a 30-keV MR-ToF device for highly sensitive collinear laser spectroscopy
title_full_unstemmed Simulation studies of a 30-keV MR-ToF device for highly sensitive collinear laser spectroscopy
title_short Simulation studies of a 30-keV MR-ToF device for highly sensitive collinear laser spectroscopy
title_sort simulation studies of a 30-kev mr-tof device for highly sensitive collinear laser spectroscopy
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1016/j.nima.2022.167927
http://cds.cern.ch/record/2847616
work_keys_str_mv AT maierfm simulationstudiesofa30kevmrtofdeviceforhighlysensitivecollinearlaserspectroscopy
AT vilenm simulationstudiesofa30kevmrtofdeviceforhighlysensitivecollinearlaserspectroscopy
AT belosevici simulationstudiesofa30kevmrtofdeviceforhighlysensitivecollinearlaserspectroscopy
AT buchingerf simulationstudiesofa30kevmrtofdeviceforhighlysensitivecollinearlaserspectroscopy
AT kanitzc simulationstudiesofa30kevmrtofdeviceforhighlysensitivecollinearlaserspectroscopy
AT lechners simulationstudiesofa30kevmrtofdeviceforhighlysensitivecollinearlaserspectroscopy
AT leistenschneidere simulationstudiesofa30kevmrtofdeviceforhighlysensitivecollinearlaserspectroscopy
AT nortershauserw simulationstudiesofa30kevmrtofdeviceforhighlysensitivecollinearlaserspectroscopy
AT plattnerp simulationstudiesofa30kevmrtofdeviceforhighlysensitivecollinearlaserspectroscopy
AT schweikhardl simulationstudiesofa30kevmrtofdeviceforhighlysensitivecollinearlaserspectroscopy
AT selss simulationstudiesofa30kevmrtofdeviceforhighlysensitivecollinearlaserspectroscopy
AT wienholtzf simulationstudiesofa30kevmrtofdeviceforhighlysensitivecollinearlaserspectroscopy
AT malbrunotettenauers simulationstudiesofa30kevmrtofdeviceforhighlysensitivecollinearlaserspectroscopy