Cargando…

Evaluation and modelling of the lithium fluoride based thermoluminescent detector response at the CERN-EU high-energy reference field (CERF)

Lithium fluoride (LiF) thermoluminescent detectors (TLDs) are commonly used for measurements in mixed high energy radiation fields such as space, hadron radiotherapy and other high energy accelerator facilities. However, the results of these measurements are often challenging to interpret since the...

Descripción completa

Detalles Bibliográficos
Autores principales: Van Hoey, Olivier, De Saint-Hubert, Marijke, Parisi, Alessio, Caballero-Pacheco, Miguel Ángel, Domingo, Carles, Pozzi, Fabio, Froeschl, Robert, Stolarczyk, Liliana, Olko, Pawel
Lenguaje:eng
Publicado: 2023
Materias:
Acceso en línea:https://dx.doi.org/10.1016/j.radmeas.2023.106923
http://cds.cern.ch/record/2856554
_version_ 1780977521831968768
author Van Hoey, Olivier
De Saint-Hubert, Marijke
Parisi, Alessio
Caballero-Pacheco, Miguel Ángel
Domingo, Carles
Pozzi, Fabio
Froeschl, Robert
Stolarczyk, Liliana
Olko, Pawel
author_facet Van Hoey, Olivier
De Saint-Hubert, Marijke
Parisi, Alessio
Caballero-Pacheco, Miguel Ángel
Domingo, Carles
Pozzi, Fabio
Froeschl, Robert
Stolarczyk, Liliana
Olko, Pawel
author_sort Van Hoey, Olivier
collection CERN
description Lithium fluoride (LiF) thermoluminescent detectors (TLDs) are commonly used for measurements in mixed high energy radiation fields such as space, hadron radiotherapy and other high energy accelerator facilities. However, the results of these measurements are often challenging to interpret since the radiation field compositions are not known a priori. The goal of this work was to model and understand the LiF TLD response in the CERN-EU high-energy Reference Field (CERF). Six different LiF TLD types, namely MTS (LiF:Mg,Ti) and MCP (LiF:Mg,Cu,P) TLDs with different Li abundances, were irradiated at CERF. For the modelling of their response, CERF reference fluence energy spectra from FLUKA simulations and TLD relative luminescence efficiencies according to the Microdosimetric d(z) Model were collected from previous works and supplemented with new relative luminescence efficiency calculations for neutrons with energies above 0.01 MeV. Dedicated MCNP6.2 simulations were performed to obtain the required fluence to absorbed dose conversion factors. Results demonstrated that the response of LiF detectors can be well predicted even for complicated, mixed radiation fields. The modelling allowed to assess the dose contributions from different radiation types in mixed fields. Based on the results of this work, a methodology was proposed to perform LiF TLD measurements in well-characterized mixed fields in terms of absorbed dose in water or tissue. In unknown mixed radiation fields MTS-7 TLDs are recommended to assess the non-neutron component of the absorbed dose in water or tissue. Assessing the dose from neutrons requires dedicated neutron detectors. •Six different LiF TLD types were used for dose assessment at CERF.•The response of these TLDs and the contributions from different radiation types were modelled in detail.•Measured and modelled doses were in good agreement with each other.•Recommendations were given for LiF TLD measurements in mixed radiation fields such as hadron therapy and space.
id cern-2856554
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2023
record_format invenio
spelling cern-28565542023-04-20T20:40:08Zdoi:10.1016/j.radmeas.2023.106923http://cds.cern.ch/record/2856554engVan Hoey, OlivierDe Saint-Hubert, MarijkeParisi, AlessioCaballero-Pacheco, Miguel ÁngelDomingo, CarlesPozzi, FabioFroeschl, RobertStolarczyk, LilianaOlko, PawelEvaluation and modelling of the lithium fluoride based thermoluminescent detector response at the CERN-EU high-energy reference field (CERF)Detectors and Experimental TechniquesLithium fluoride (LiF) thermoluminescent detectors (TLDs) are commonly used for measurements in mixed high energy radiation fields such as space, hadron radiotherapy and other high energy accelerator facilities. However, the results of these measurements are often challenging to interpret since the radiation field compositions are not known a priori. The goal of this work was to model and understand the LiF TLD response in the CERN-EU high-energy Reference Field (CERF). Six different LiF TLD types, namely MTS (LiF:Mg,Ti) and MCP (LiF:Mg,Cu,P) TLDs with different Li abundances, were irradiated at CERF. For the modelling of their response, CERF reference fluence energy spectra from FLUKA simulations and TLD relative luminescence efficiencies according to the Microdosimetric d(z) Model were collected from previous works and supplemented with new relative luminescence efficiency calculations for neutrons with energies above 0.01 MeV. Dedicated MCNP6.2 simulations were performed to obtain the required fluence to absorbed dose conversion factors. Results demonstrated that the response of LiF detectors can be well predicted even for complicated, mixed radiation fields. The modelling allowed to assess the dose contributions from different radiation types in mixed fields. Based on the results of this work, a methodology was proposed to perform LiF TLD measurements in well-characterized mixed fields in terms of absorbed dose in water or tissue. In unknown mixed radiation fields MTS-7 TLDs are recommended to assess the non-neutron component of the absorbed dose in water or tissue. Assessing the dose from neutrons requires dedicated neutron detectors. •Six different LiF TLD types were used for dose assessment at CERF.•The response of these TLDs and the contributions from different radiation types were modelled in detail.•Measured and modelled doses were in good agreement with each other.•Recommendations were given for LiF TLD measurements in mixed radiation fields such as hadron therapy and space.oai:cds.cern.ch:28565542023
spellingShingle Detectors and Experimental Techniques
Van Hoey, Olivier
De Saint-Hubert, Marijke
Parisi, Alessio
Caballero-Pacheco, Miguel Ángel
Domingo, Carles
Pozzi, Fabio
Froeschl, Robert
Stolarczyk, Liliana
Olko, Pawel
Evaluation and modelling of the lithium fluoride based thermoluminescent detector response at the CERN-EU high-energy reference field (CERF)
title Evaluation and modelling of the lithium fluoride based thermoluminescent detector response at the CERN-EU high-energy reference field (CERF)
title_full Evaluation and modelling of the lithium fluoride based thermoluminescent detector response at the CERN-EU high-energy reference field (CERF)
title_fullStr Evaluation and modelling of the lithium fluoride based thermoluminescent detector response at the CERN-EU high-energy reference field (CERF)
title_full_unstemmed Evaluation and modelling of the lithium fluoride based thermoluminescent detector response at the CERN-EU high-energy reference field (CERF)
title_short Evaluation and modelling of the lithium fluoride based thermoluminescent detector response at the CERN-EU high-energy reference field (CERF)
title_sort evaluation and modelling of the lithium fluoride based thermoluminescent detector response at the cern-eu high-energy reference field (cerf)
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1016/j.radmeas.2023.106923
http://cds.cern.ch/record/2856554
work_keys_str_mv AT vanhoeyolivier evaluationandmodellingofthelithiumfluoridebasedthermoluminescentdetectorresponseatthecerneuhighenergyreferencefieldcerf
AT desainthubertmarijke evaluationandmodellingofthelithiumfluoridebasedthermoluminescentdetectorresponseatthecerneuhighenergyreferencefieldcerf
AT parisialessio evaluationandmodellingofthelithiumfluoridebasedthermoluminescentdetectorresponseatthecerneuhighenergyreferencefieldcerf
AT caballeropachecomiguelangel evaluationandmodellingofthelithiumfluoridebasedthermoluminescentdetectorresponseatthecerneuhighenergyreferencefieldcerf
AT domingocarles evaluationandmodellingofthelithiumfluoridebasedthermoluminescentdetectorresponseatthecerneuhighenergyreferencefieldcerf
AT pozzifabio evaluationandmodellingofthelithiumfluoridebasedthermoluminescentdetectorresponseatthecerneuhighenergyreferencefieldcerf
AT froeschlrobert evaluationandmodellingofthelithiumfluoridebasedthermoluminescentdetectorresponseatthecerneuhighenergyreferencefieldcerf
AT stolarczykliliana evaluationandmodellingofthelithiumfluoridebasedthermoluminescentdetectorresponseatthecerneuhighenergyreferencefieldcerf
AT olkopawel evaluationandmodellingofthelithiumfluoridebasedthermoluminescentdetectorresponseatthecerneuhighenergyreferencefieldcerf