Model Predictive Control of Air Handling Unit for a Single Zone Setup

Heating Ventilation and Air Conditioning (HVAC) systems are one of the main consumers of electrical energy. Being an essential component in HVAC systems, optimal operation of the air handling units (AHUs) can result in significant energy savings. In this paper, we study the modeling and optimal cont...

Descripción completa

Detalles Bibliográficos
Autores principales: Ghawash, Faiq, Hovd, Morten, Schofield, Brad, Monteiro, Diogo
Lenguaje:eng
Publicado: 2022
Materias:
Acceso en línea:https://dx.doi.org/10.1109/adconip55568.2022.9894128
http://cds.cern.ch/record/2857851
_version_ 1780977590233726976
author Ghawash, Faiq
Hovd, Morten
Schofield, Brad
Monteiro, Diogo
author_facet Ghawash, Faiq
Hovd, Morten
Schofield, Brad
Monteiro, Diogo
author_sort Ghawash, Faiq
collection CERN
description Heating Ventilation and Air Conditioning (HVAC) systems are one of the main consumers of electrical energy. Being an essential component in HVAC systems, optimal operation of the air handling units (AHUs) can result in significant energy savings. In this paper, we study the modeling and optimal control of AHUs which can be operated in different modes (active cooling, economizer and active heating) to regulate the zone temperature within the desirable range. A simple control oriented model based on mass and energy balances is presented and validated against the operational data. A nonlinear optimization program is formulated which accounts for different operational modes to enable optimal operation of the AHU. The proposed framework can be effectively applied to different AHU setups. An illustrative example is provided to show the effectiveness of the proposed approach.
id cern-2857851
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2022
record_format invenio
spelling cern-28578512023-05-15T12:24:14Zdoi:10.1109/adconip55568.2022.9894128http://cds.cern.ch/record/2857851engGhawash, FaiqHovd, MortenSchofield, BradMonteiro, DiogoModel Predictive Control of Air Handling Unit for a Single Zone SetupEngineeringHeating Ventilation and Air Conditioning (HVAC) systems are one of the main consumers of electrical energy. Being an essential component in HVAC systems, optimal operation of the air handling units (AHUs) can result in significant energy savings. In this paper, we study the modeling and optimal control of AHUs which can be operated in different modes (active cooling, economizer and active heating) to regulate the zone temperature within the desirable range. A simple control oriented model based on mass and energy balances is presented and validated against the operational data. A nonlinear optimization program is formulated which accounts for different operational modes to enable optimal operation of the AHU. The proposed framework can be effectively applied to different AHU setups. An illustrative example is provided to show the effectiveness of the proposed approach.oai:cds.cern.ch:28578512022
spellingShingle Engineering
Ghawash, Faiq
Hovd, Morten
Schofield, Brad
Monteiro, Diogo
Model Predictive Control of Air Handling Unit for a Single Zone Setup
title Model Predictive Control of Air Handling Unit for a Single Zone Setup
title_full Model Predictive Control of Air Handling Unit for a Single Zone Setup
title_fullStr Model Predictive Control of Air Handling Unit for a Single Zone Setup
title_full_unstemmed Model Predictive Control of Air Handling Unit for a Single Zone Setup
title_short Model Predictive Control of Air Handling Unit for a Single Zone Setup
title_sort model predictive control of air handling unit for a single zone setup
topic Engineering
url https://dx.doi.org/10.1109/adconip55568.2022.9894128
http://cds.cern.ch/record/2857851
work_keys_str_mv AT ghawashfaiq modelpredictivecontrolofairhandlingunitforasinglezonesetup
AT hovdmorten modelpredictivecontrolofairhandlingunitforasinglezonesetup
AT schofieldbrad modelpredictivecontrolofairhandlingunitforasinglezonesetup
AT monteirodiogo modelpredictivecontrolofairhandlingunitforasinglezonesetup