Cargando…

Improved Resistive Plate Chambers for the upgrade of the CMS muon detector

Several upgrades of the Resistive Plate Chamber (RPC) system of the Compact Muon Solenoid (CMS) experiment are currently being implemented to ensure a highly performing muon system during the upcoming High Luminosity phase of the Large Hadron Collider which will have an increased integrated luminosi...

Descripción completa

Detalles Bibliográficos
Autor principal: Samalan, A
Lenguaje:eng
Publicado: 2022
Materias:
Acceso en línea:https://dx.doi.org/10.1088/1742-6596/2374/1/012006
http://cds.cern.ch/record/2861223
_version_ 1780977809014915072
author Samalan, A
author_facet Samalan, A
author_sort Samalan, A
collection CERN
description Several upgrades of the Resistive Plate Chamber (RPC) system of the Compact Muon Solenoid (CMS) experiment are currently being implemented to ensure a highly performing muon system during the upcoming High Luminosity phase of the Large Hadron Collider which will have an increased integrated luminosity of 3000 fb$^{−1}$. The expected experimental conditions in that period present a challenge for the entire CMS detection system. To extend the RPC coverage, an improved version of the already existing RPCs will be installed in the forward region of the 3rd and 4th endcap disks. The current overall status of this CMS RPC upgrade project is presented.
id cern-2861223
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2022
record_format invenio
spelling cern-28612232023-06-16T09:52:41Zdoi:10.1088/1742-6596/2374/1/012006http://cds.cern.ch/record/2861223engSamalan, AImproved Resistive Plate Chambers for the upgrade of the CMS muon detectorDetectors and Experimental TechniquesSeveral upgrades of the Resistive Plate Chamber (RPC) system of the Compact Muon Solenoid (CMS) experiment are currently being implemented to ensure a highly performing muon system during the upcoming High Luminosity phase of the Large Hadron Collider which will have an increased integrated luminosity of 3000 fb$^{−1}$. The expected experimental conditions in that period present a challenge for the entire CMS detection system. To extend the RPC coverage, an improved version of the already existing RPCs will be installed in the forward region of the 3rd and 4th endcap disks. The current overall status of this CMS RPC upgrade project is presented.oai:cds.cern.ch:28612232022
spellingShingle Detectors and Experimental Techniques
Samalan, A
Improved Resistive Plate Chambers for the upgrade of the CMS muon detector
title Improved Resistive Plate Chambers for the upgrade of the CMS muon detector
title_full Improved Resistive Plate Chambers for the upgrade of the CMS muon detector
title_fullStr Improved Resistive Plate Chambers for the upgrade of the CMS muon detector
title_full_unstemmed Improved Resistive Plate Chambers for the upgrade of the CMS muon detector
title_short Improved Resistive Plate Chambers for the upgrade of the CMS muon detector
title_sort improved resistive plate chambers for the upgrade of the cms muon detector
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1088/1742-6596/2374/1/012006
http://cds.cern.ch/record/2861223
work_keys_str_mv AT samalana improvedresistiveplatechambersfortheupgradeofthecmsmuondetector