Cargando…

ALVAREZ DRIFT TUBE LINAC FOR MEDICAL APPLICATIONS IN THE FRAMEWORK OF HITRIPLUS PROJECT

A first beam dynamics and RF design of an Alvarez-type drift tube linac (DTL) has been defined in the framework of the EU project, HITRIplus. It is meant primarily as a carbon (12C4+) and helium (4He2+) ion injector of a compact synchrotron for patient treatment. As a second implemen-tation, helium...

Descripción completa

Detalles Bibliográficos
Autores principales: Mamaras, Aristeidis, Samponidis, D, Bellan, L, Bisoffi, Giovanni, Comunian, M, Thonet, Pierre Alexandre, Vretenar, Maurizio
Lenguaje:eng
Publicado: 2023
Materias:
Acceso en línea:http://cds.cern.ch/record/2864875
_version_ 1780978013250256896
author Mamaras, Aristeidis
Samponidis, D
Bellan, L
Bisoffi, Giovanni
Comunian, M
Thonet, Pierre Alexandre
Vretenar, Maurizio
author_facet Mamaras, Aristeidis
Samponidis, D
Bellan, L
Bisoffi, Giovanni
Comunian, M
Thonet, Pierre Alexandre
Vretenar, Maurizio
author_sort Mamaras, Aristeidis
collection CERN
description A first beam dynamics and RF design of an Alvarez-type drift tube linac (DTL) has been defined in the framework of the EU project, HITRIplus. It is meant primarily as a carbon (12C4+) and helium (4He2+) ion injector of a compact synchrotron for patient treatment. As a second implemen-tation, helium particle acceleration with a higher duty cycle (10%) enables radioisotope production. The 352.2 MHz structure efficiently accelerates ion species with A/q=3 and 2, in the energy range from 1 to 5 MeV/u and for a beam current up to ~0.5 mA. The design extends to a full length of ~6.4 meters. Permanent magnet quadrupoles are utilized all along the DTL for focusing both ion beams. This paper presents a first-phase analysis towards a realistic DTL de-sign capable of providing full beam transmission and min-imum overall emittance increase for both A/q values.
id cern-2864875
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2023
record_format invenio
spelling cern-28648752023-07-12T21:27:39Zhttp://cds.cern.ch/record/2864875engMamaras, AristeidisSamponidis, DBellan, LBisoffi, GiovanniComunian, MThonet, Pierre AlexandreVretenar, MaurizioALVAREZ DRIFT TUBE LINAC FOR MEDICAL APPLICATIONS IN THE FRAMEWORK OF HITRIPLUS PROJECTAccelerators and Storage RingsA first beam dynamics and RF design of an Alvarez-type drift tube linac (DTL) has been defined in the framework of the EU project, HITRIplus. It is meant primarily as a carbon (12C4+) and helium (4He2+) ion injector of a compact synchrotron for patient treatment. As a second implemen-tation, helium particle acceleration with a higher duty cycle (10%) enables radioisotope production. The 352.2 MHz structure efficiently accelerates ion species with A/q=3 and 2, in the energy range from 1 to 5 MeV/u and for a beam current up to ~0.5 mA. The design extends to a full length of ~6.4 meters. Permanent magnet quadrupoles are utilized all along the DTL for focusing both ion beams. This paper presents a first-phase analysis towards a realistic DTL de-sign capable of providing full beam transmission and min-imum overall emittance increase for both A/q values.CERN-ACC-NOTE-2023-0008NIMMS-Note-014oai:cds.cern.ch:28648752023-06-30
spellingShingle Accelerators and Storage Rings
Mamaras, Aristeidis
Samponidis, D
Bellan, L
Bisoffi, Giovanni
Comunian, M
Thonet, Pierre Alexandre
Vretenar, Maurizio
ALVAREZ DRIFT TUBE LINAC FOR MEDICAL APPLICATIONS IN THE FRAMEWORK OF HITRIPLUS PROJECT
title ALVAREZ DRIFT TUBE LINAC FOR MEDICAL APPLICATIONS IN THE FRAMEWORK OF HITRIPLUS PROJECT
title_full ALVAREZ DRIFT TUBE LINAC FOR MEDICAL APPLICATIONS IN THE FRAMEWORK OF HITRIPLUS PROJECT
title_fullStr ALVAREZ DRIFT TUBE LINAC FOR MEDICAL APPLICATIONS IN THE FRAMEWORK OF HITRIPLUS PROJECT
title_full_unstemmed ALVAREZ DRIFT TUBE LINAC FOR MEDICAL APPLICATIONS IN THE FRAMEWORK OF HITRIPLUS PROJECT
title_short ALVAREZ DRIFT TUBE LINAC FOR MEDICAL APPLICATIONS IN THE FRAMEWORK OF HITRIPLUS PROJECT
title_sort alvarez drift tube linac for medical applications in the framework of hitriplus project
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/2864875
work_keys_str_mv AT mamarasaristeidis alvarezdrifttubelinacformedicalapplicationsintheframeworkofhitriplusproject
AT samponidisd alvarezdrifttubelinacformedicalapplicationsintheframeworkofhitriplusproject
AT bellanl alvarezdrifttubelinacformedicalapplicationsintheframeworkofhitriplusproject
AT bisoffigiovanni alvarezdrifttubelinacformedicalapplicationsintheframeworkofhitriplusproject
AT comunianm alvarezdrifttubelinacformedicalapplicationsintheframeworkofhitriplusproject
AT thonetpierrealexandre alvarezdrifttubelinacformedicalapplicationsintheframeworkofhitriplusproject
AT vretenarmaurizio alvarezdrifttubelinacformedicalapplicationsintheframeworkofhitriplusproject