Cargando…
Beam test, simulation, and performance evaluation of PbF$_2$ and PWO-UF crystals with SiPM readout for a semi-homogeneous calorimeter prototype with longitudinal segmentation
Crilin (Crystal Calorimeter with Longitudinal Information) is a semi-homogeneous, longitudinally segmented electromagnetic calorimeter based on high-𝑍, ultra-fast crystals with UV-extended SiPM readout. The Crilin design has been proposed as a candidate solution for both a future Muon Collider barre...
Autores principales: | , , , , , , , , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2023
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.3389/fphy.2023.1223183 http://cds.cern.ch/record/2867721 |
_version_ | 1780978173268197376 |
---|---|
author | Cantone, C. Carsi, S. Ceravolo, S. Di Meco, E. Diociaiuti, E. Frank, I. Kholodenko, S. Martellotti, S. Mirra, M. Monti-Guarnieri, P. Moulson, M. Paesani, D. Prest, M. Romagnoni, M. Sarra, I. Sgarbossa, F. Soldani, M. Vallazza, E. |
author_facet | Cantone, C. Carsi, S. Ceravolo, S. Di Meco, E. Diociaiuti, E. Frank, I. Kholodenko, S. Martellotti, S. Mirra, M. Monti-Guarnieri, P. Moulson, M. Paesani, D. Prest, M. Romagnoni, M. Sarra, I. Sgarbossa, F. Soldani, M. Vallazza, E. |
author_sort | Cantone, C. |
collection | CERN |
description | Crilin (Crystal Calorimeter with Longitudinal Information) is a semi-homogeneous, longitudinally segmented electromagnetic calorimeter based on high-𝑍, ultra-fast crystals with UV-extended SiPM readout. The Crilin design has been proposed as a candidate solution for both a future Muon Collider barrel ECAL and for the Small Angle Calorimeter of the HIKE experiment. As a part of the Crilin development program, we have carried out beam tests of small (10 × 10 × 40 mm 3 ) lead fluoride (PbF 2 ) and ultra-fast lead tungstate (PbWO 4 , PWO-UF) crystals with 120 GeV electrons at the CERN SPS to study the light yield, timing response, and systematics of light collection with a proposed readout 1 D. Paesani et al.scheme. For a single crystal of PbF 2 , corresponding to a single Crilin cell, a time resolution of better than 25 ps is obtained for >3 GeV of deposited energy. For a single cell of PWO-UF, a time resolution of better than 45 ps is obtained for the same range of deposited energy. This timing performance fully satisfies the design requirements for the Muon Collider and HIKE experiments. Further optimizations of the readout scheme and crystal surface preparation are expected to bring further improvements. |
id | cern-2867721 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2023 |
record_format | invenio |
spelling | cern-28677212023-09-01T13:47:43Zdoi:10.3389/fphy.2023.1223183http://cds.cern.ch/record/2867721engCantone, C.Carsi, S.Ceravolo, S.Di Meco, E.Diociaiuti, E.Frank, I.Kholodenko, S.Martellotti, S.Mirra, M.Monti-Guarnieri, P.Moulson, M.Paesani, D.Prest, M.Romagnoni, M.Sarra, I.Sgarbossa, F.Soldani, M.Vallazza, E.Beam test, simulation, and performance evaluation of PbF$_2$ and PWO-UF crystals with SiPM readout for a semi-homogeneous calorimeter prototype with longitudinal segmentationhep-exParticle Physics - Experimentphysics.ins-detDetectors and Experimental TechniquesCrilin (Crystal Calorimeter with Longitudinal Information) is a semi-homogeneous, longitudinally segmented electromagnetic calorimeter based on high-𝑍, ultra-fast crystals with UV-extended SiPM readout. The Crilin design has been proposed as a candidate solution for both a future Muon Collider barrel ECAL and for the Small Angle Calorimeter of the HIKE experiment. As a part of the Crilin development program, we have carried out beam tests of small (10 × 10 × 40 mm 3 ) lead fluoride (PbF 2 ) and ultra-fast lead tungstate (PbWO 4 , PWO-UF) crystals with 120 GeV electrons at the CERN SPS to study the light yield, timing response, and systematics of light collection with a proposed readout 1 D. Paesani et al.scheme. For a single crystal of PbF 2 , corresponding to a single Crilin cell, a time resolution of better than 25 ps is obtained for >3 GeV of deposited energy. For a single cell of PWO-UF, a time resolution of better than 45 ps is obtained for the same range of deposited energy. This timing performance fully satisfies the design requirements for the Muon Collider and HIKE experiments. Further optimizations of the readout scheme and crystal surface preparation are expected to bring further improvements.Crilin (Crystal Calorimeter with Longitudinal Information) is a semi-homogeneous, longitudinally segmented electromagnetic calorimeter based on high-$Z$, ultra-fast crystals with UV-extended SiPM readout. The Crilin design has been proposed as a candidate solution for both a future Muon Collider barrel ECAL and for the Small Angle Calorimeter of the HIKE experiment. As a part of the Crilin development program, we have carried out beam tests of small ($10\times10\times40$~mm$^3$) lead fluoride (PbF$_2$) and ultra-fast lead tungstate (PbWO$_4$, PWO) crystals with 120~GeV electrons at the CERN SPS to study the light yield, timing response, and systematics of light collection with a proposed readout scheme. For a single crystal of PbF$_2$, corresponding to a single Crilin cell, a time resolution of better than 25~ps is obtained for $>$3 GeV of deposited energy. For a single cell of \pwo, a time resolution of better than 45~ps is obtained for the same range of deposited energy. This timing performance fully satisfies the design requirements for the Muon Collider and HIKE experiments. Further optimizations of the readout scheme and crystal surface preparation are expected to bring further improvements.arXiv:2308.01148oai:cds.cern.ch:28677212023-08-02 |
spellingShingle | hep-ex Particle Physics - Experiment physics.ins-det Detectors and Experimental Techniques Cantone, C. Carsi, S. Ceravolo, S. Di Meco, E. Diociaiuti, E. Frank, I. Kholodenko, S. Martellotti, S. Mirra, M. Monti-Guarnieri, P. Moulson, M. Paesani, D. Prest, M. Romagnoni, M. Sarra, I. Sgarbossa, F. Soldani, M. Vallazza, E. Beam test, simulation, and performance evaluation of PbF$_2$ and PWO-UF crystals with SiPM readout for a semi-homogeneous calorimeter prototype with longitudinal segmentation |
title | Beam test, simulation, and performance evaluation of PbF$_2$ and PWO-UF crystals with SiPM readout for a semi-homogeneous calorimeter prototype with longitudinal segmentation |
title_full | Beam test, simulation, and performance evaluation of PbF$_2$ and PWO-UF crystals with SiPM readout for a semi-homogeneous calorimeter prototype with longitudinal segmentation |
title_fullStr | Beam test, simulation, and performance evaluation of PbF$_2$ and PWO-UF crystals with SiPM readout for a semi-homogeneous calorimeter prototype with longitudinal segmentation |
title_full_unstemmed | Beam test, simulation, and performance evaluation of PbF$_2$ and PWO-UF crystals with SiPM readout for a semi-homogeneous calorimeter prototype with longitudinal segmentation |
title_short | Beam test, simulation, and performance evaluation of PbF$_2$ and PWO-UF crystals with SiPM readout for a semi-homogeneous calorimeter prototype with longitudinal segmentation |
title_sort | beam test, simulation, and performance evaluation of pbf$_2$ and pwo-uf crystals with sipm readout for a semi-homogeneous calorimeter prototype with longitudinal segmentation |
topic | hep-ex Particle Physics - Experiment physics.ins-det Detectors and Experimental Techniques |
url | https://dx.doi.org/10.3389/fphy.2023.1223183 http://cds.cern.ch/record/2867721 |
work_keys_str_mv | AT cantonec beamtestsimulationandperformanceevaluationofpbf2andpwoufcrystalswithsipmreadoutforasemihomogeneouscalorimeterprototypewithlongitudinalsegmentation AT carsis beamtestsimulationandperformanceevaluationofpbf2andpwoufcrystalswithsipmreadoutforasemihomogeneouscalorimeterprototypewithlongitudinalsegmentation AT ceravolos beamtestsimulationandperformanceevaluationofpbf2andpwoufcrystalswithsipmreadoutforasemihomogeneouscalorimeterprototypewithlongitudinalsegmentation AT dimecoe beamtestsimulationandperformanceevaluationofpbf2andpwoufcrystalswithsipmreadoutforasemihomogeneouscalorimeterprototypewithlongitudinalsegmentation AT diociaiutie beamtestsimulationandperformanceevaluationofpbf2andpwoufcrystalswithsipmreadoutforasemihomogeneouscalorimeterprototypewithlongitudinalsegmentation AT franki beamtestsimulationandperformanceevaluationofpbf2andpwoufcrystalswithsipmreadoutforasemihomogeneouscalorimeterprototypewithlongitudinalsegmentation AT kholodenkos beamtestsimulationandperformanceevaluationofpbf2andpwoufcrystalswithsipmreadoutforasemihomogeneouscalorimeterprototypewithlongitudinalsegmentation AT martellottis beamtestsimulationandperformanceevaluationofpbf2andpwoufcrystalswithsipmreadoutforasemihomogeneouscalorimeterprototypewithlongitudinalsegmentation AT mirram beamtestsimulationandperformanceevaluationofpbf2andpwoufcrystalswithsipmreadoutforasemihomogeneouscalorimeterprototypewithlongitudinalsegmentation AT montiguarnierip beamtestsimulationandperformanceevaluationofpbf2andpwoufcrystalswithsipmreadoutforasemihomogeneouscalorimeterprototypewithlongitudinalsegmentation AT moulsonm beamtestsimulationandperformanceevaluationofpbf2andpwoufcrystalswithsipmreadoutforasemihomogeneouscalorimeterprototypewithlongitudinalsegmentation AT paesanid beamtestsimulationandperformanceevaluationofpbf2andpwoufcrystalswithsipmreadoutforasemihomogeneouscalorimeterprototypewithlongitudinalsegmentation AT prestm beamtestsimulationandperformanceevaluationofpbf2andpwoufcrystalswithsipmreadoutforasemihomogeneouscalorimeterprototypewithlongitudinalsegmentation AT romagnonim beamtestsimulationandperformanceevaluationofpbf2andpwoufcrystalswithsipmreadoutforasemihomogeneouscalorimeterprototypewithlongitudinalsegmentation AT sarrai beamtestsimulationandperformanceevaluationofpbf2andpwoufcrystalswithsipmreadoutforasemihomogeneouscalorimeterprototypewithlongitudinalsegmentation AT sgarbossaf beamtestsimulationandperformanceevaluationofpbf2andpwoufcrystalswithsipmreadoutforasemihomogeneouscalorimeterprototypewithlongitudinalsegmentation AT soldanim beamtestsimulationandperformanceevaluationofpbf2andpwoufcrystalswithsipmreadoutforasemihomogeneouscalorimeterprototypewithlongitudinalsegmentation AT vallazzae beamtestsimulationandperformanceevaluationofpbf2andpwoufcrystalswithsipmreadoutforasemihomogeneouscalorimeterprototypewithlongitudinalsegmentation |