Cargando…
Luminometer linearity study with 2023 BSRT fill data and dedicated beam-beam corrections
Preliminary results from the analysis of the LHC fill 8778 in 2023. Nine bunches with different emittances are scanned using the vdM method and dedicated beam corrections. The results measure the beam-overlap profiles and provide a study of the BCM1F and PLT luminometer linearities.
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2023
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/2871593 |
_version_ | 1780978554113097728 |
---|---|
author | CMS Collaboration |
author_facet | CMS Collaboration |
author_sort | CMS Collaboration |
collection | CERN |
description | Preliminary results from the analysis of the LHC fill 8778 in 2023. Nine bunches with different emittances are scanned using the vdM method and dedicated beam corrections. The results measure the beam-overlap profiles and provide a study of the BCM1F and PLT luminometer linearities. |
id | cern-2871593 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2023 |
record_format | invenio |
spelling | cern-28715932023-09-18T18:54:13Zhttp://cds.cern.ch/record/2871593engCMS CollaborationLuminometer linearity study with 2023 BSRT fill data and dedicated beam-beam correctionsDetectors and Experimental TechniquesPreliminary results from the analysis of the LHC fill 8778 in 2023. Nine bunches with different emittances are scanned using the vdM method and dedicated beam corrections. The results measure the beam-overlap profiles and provide a study of the BCM1F and PLT luminometer linearities.CMS-DP-2023-073CERN-CMS-DP-2023-073oai:cds.cern.ch:28715932023-09-14 |
spellingShingle | Detectors and Experimental Techniques CMS Collaboration Luminometer linearity study with 2023 BSRT fill data and dedicated beam-beam corrections |
title | Luminometer linearity study with 2023 BSRT fill data and dedicated beam-beam corrections |
title_full | Luminometer linearity study with 2023 BSRT fill data and dedicated beam-beam corrections |
title_fullStr | Luminometer linearity study with 2023 BSRT fill data and dedicated beam-beam corrections |
title_full_unstemmed | Luminometer linearity study with 2023 BSRT fill data and dedicated beam-beam corrections |
title_short | Luminometer linearity study with 2023 BSRT fill data and dedicated beam-beam corrections |
title_sort | luminometer linearity study with 2023 bsrt fill data and dedicated beam-beam corrections |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/2871593 |
work_keys_str_mv | AT cmscollaboration luminometerlinearitystudywith2023bsrtfilldataanddedicatedbeambeamcorrections |