Cargando…
GaAs microstrip test beam results
A gallium arsenide detector was tested with a beam of 70GeV pions at the {\sf SPS} at CERN. The detector utilises a novel biasing scheme which has been shown to behave as expected. The detector has a pitch of 50\mum and therefore an expected resolution of 14.5\mum. The measured resolution was approx...
Autores principales: | Gowdy, S.J., Bates, R.L., Buttar, C., D'Auria, S., del Papa, C., Dulinski, W., Manolopoulos, S., O'Shea, V., Sloan, T., Raine, C., Smith, K.M., Thomson, F.K. |
---|---|
Lenguaje: | eng |
Publicado: |
1995
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/288022 |