Cargando…

LKr calorimetry for the CP violation experiment NA48: recent test beam results

The NA48 collaboration is preparing a new experiment at CERN aiming to measure $\epsilon'/\epsilon$ in the $K^{0}-K^{0}$ system to the level of $2 \times 10^{−4}$. The heart of the detector will be the electromagnetic calorimeter needed to reconstruct the neutral kaon decays. The choice of a li...

Descripción completa

Detalles Bibliográficos
Autor principal: Ceccucci, Augusto
Lenguaje:eng
Publicado: 1995
Materias:
Acceso en línea:https://dx.doi.org/10.1016/0168-9002(94)01717-4
http://cds.cern.ch/record/290114
_version_ 1780888581720506368
author Ceccucci, Augusto
author_facet Ceccucci, Augusto
author_sort Ceccucci, Augusto
collection CERN
description The NA48 collaboration is preparing a new experiment at CERN aiming to measure $\epsilon'/\epsilon$ in the $K^{0}-K^{0}$ system to the level of $2 \times 10^{−4}$. The heart of the detector will be the electromagnetic calorimeter needed to reconstruct the neutral kaon decays. The choice of a liquid krypton calorimeter has been dictated by the need to combine excellent energy, position and time resolution with the possibility of a precise charge calibration and long term stability. Results obtained by means of a prototype calorimeter incorporating the final design of the electrode readout structure are presented.
id cern-290114
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 1995
record_format invenio
spelling cern-2901142019-09-30T06:29:59Zdoi:10.1016/0168-9002(94)01717-4http://cds.cern.ch/record/290114engCeccucci, AugustoLKr calorimetry for the CP violation experiment NA48: recent test beam resultsDetectors and Experimental TechniquesThe NA48 collaboration is preparing a new experiment at CERN aiming to measure $\epsilon'/\epsilon$ in the $K^{0}-K^{0}$ system to the level of $2 \times 10^{−4}$. The heart of the detector will be the electromagnetic calorimeter needed to reconstruct the neutral kaon decays. The choice of a liquid krypton calorimeter has been dictated by the need to combine excellent energy, position and time resolution with the possibility of a precise charge calibration and long term stability. Results obtained by means of a prototype calorimeter incorporating the final design of the electrode readout structure are presented.oai:cds.cern.ch:2901141995
spellingShingle Detectors and Experimental Techniques
Ceccucci, Augusto
LKr calorimetry for the CP violation experiment NA48: recent test beam results
title LKr calorimetry for the CP violation experiment NA48: recent test beam results
title_full LKr calorimetry for the CP violation experiment NA48: recent test beam results
title_fullStr LKr calorimetry for the CP violation experiment NA48: recent test beam results
title_full_unstemmed LKr calorimetry for the CP violation experiment NA48: recent test beam results
title_short LKr calorimetry for the CP violation experiment NA48: recent test beam results
title_sort lkr calorimetry for the cp violation experiment na48: recent test beam results
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1016/0168-9002(94)01717-4
http://cds.cern.ch/record/290114
work_keys_str_mv AT ceccucciaugusto lkrcalorimetryforthecpviolationexperimentna48recenttestbeamresults