An ISPA-camera for $\beta$-radiography

We have developed a new type of beta-camera based on an Imaging Silicon Pixel Array (ISPA)-tube combined with planar plastic scintillators or with SiY2O5(Ce)-scintillating powder. The ISPA-tube consists of a photocathode viewed at 3 cm distance by a silicon anode divided into 1024 rectangular (75 mi...

Descripción completa

Detalles Bibliográficos
Autores principales: Puertolas, D, Piedigrossi, D, Leutz, H, Gys, Thierry, D'Ambrosio, C
Lenguaje:eng
Publicado: 1995
Materias:
Acceso en línea:https://dx.doi.org/10.1109/23.539395
http://cds.cern.ch/record/298603
_version_ 1780889283914104832
author Puertolas, D
Piedigrossi, D
Leutz, H
Gys, Thierry
D'Ambrosio, C
author_facet Puertolas, D
Piedigrossi, D
Leutz, H
Gys, Thierry
D'Ambrosio, C
author_sort Puertolas, D
collection CERN
description We have developed a new type of beta-camera based on an Imaging Silicon Pixel Array (ISPA)-tube combined with planar plastic scintillators or with SiY2O5(Ce)-scintillating powder. The ISPA-tube consists of a photocathode viewed at 3 cm distance by a silicon anode divided into 1024 rectangular (75 microm x 500 microm) detector pixels, each bump-bonded to its equally-sized electronic pixel. Depending on the beta-detector thickness we achieved spatial resolutions (FWHM) between 105 microm (63Ni source and 30 microm thick plastic scintillator) and 240 microm (90Sr-90Y source and 120 microm thick plastic scintillator) by covering the detectors with brass templates. With their four 60 microm wide slits oriented parallel to the long pixel edges we simulated small sized beta-strips. The impact of detector thickness is explained by multiple scattering, angular aperture of the template slits and scintillating light distribution at the ISPA-photocathode. Beta detection sensitivities were measured with calibrated 3H (tritium)- and 14C-Amersham microscale sources. They amount to 0.1 Bq (3H) with 150 min counting time and to 0.025 Bq (14C) with 180 min counting time.
id cern-298603
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 1995
record_format invenio
spelling cern-2986032019-09-30T06:29:59Zdoi:10.1109/23.539395http://cds.cern.ch/record/298603engPuertolas, DPiedigrossi, DLeutz, HGys, ThierryD'Ambrosio, CAn ISPA-camera for $\beta$-radiographyDetectors and Experimental TechniquesWe have developed a new type of beta-camera based on an Imaging Silicon Pixel Array (ISPA)-tube combined with planar plastic scintillators or with SiY2O5(Ce)-scintillating powder. The ISPA-tube consists of a photocathode viewed at 3 cm distance by a silicon anode divided into 1024 rectangular (75 microm x 500 microm) detector pixels, each bump-bonded to its equally-sized electronic pixel. Depending on the beta-detector thickness we achieved spatial resolutions (FWHM) between 105 microm (63Ni source and 30 microm thick plastic scintillator) and 240 microm (90Sr-90Y source and 120 microm thick plastic scintillator) by covering the detectors with brass templates. With their four 60 microm wide slits oriented parallel to the long pixel edges we simulated small sized beta-strips. The impact of detector thickness is explained by multiple scattering, angular aperture of the template slits and scintillating light distribution at the ISPA-photocathode. Beta detection sensitivities were measured with calibrated 3H (tritium)- and 14C-Amersham microscale sources. They amount to 0.1 Bq (3H) with 150 min counting time and to 0.025 Bq (14C) with 180 min counting time.CERN-PPE-95-198oai:cds.cern.ch:2986031995-12-19
spellingShingle Detectors and Experimental Techniques
Puertolas, D
Piedigrossi, D
Leutz, H
Gys, Thierry
D'Ambrosio, C
An ISPA-camera for $\beta$-radiography
title An ISPA-camera for $\beta$-radiography
title_full An ISPA-camera for $\beta$-radiography
title_fullStr An ISPA-camera for $\beta$-radiography
title_full_unstemmed An ISPA-camera for $\beta$-radiography
title_short An ISPA-camera for $\beta$-radiography
title_sort ispa-camera for $\beta$-radiography
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1109/23.539395
http://cds.cern.ch/record/298603
work_keys_str_mv AT puertolasd anispacameraforbetaradiography
AT piedigrossid anispacameraforbetaradiography
AT leutzh anispacameraforbetaradiography
AT gysthierry anispacameraforbetaradiography
AT dambrosioc anispacameraforbetaradiography
AT puertolasd ispacameraforbetaradiography
AT piedigrossid ispacameraforbetaradiography
AT leutzh ispacameraforbetaradiography
AT gysthierry ispacameraforbetaradiography
AT dambrosioc ispacameraforbetaradiography