Cargando…
High rate large dynamic range analog circuitry and digitizers for fast calorimeter
This paper describes the issues encountered in the design of a large dynamic range digitizer for calorimetry. A gain switching technology developed for the liquid krypton calorimeter of the NA48 CP-violation experiment at CERN is described in detail. 14 bit dynamic range and better than 300 ps time...
Autores principales: | , , , , , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
1996
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1109/NSSMIC.1995.504258 https://dx.doi.org/10.1109/23.507155 http://cds.cern.ch/record/300720 |
_version_ | 1780889448989327360 |
---|---|
author | Hallgren, Björn I Bal, F Barr, Giles David Buchholz, P Formenti, F Funk, W Kozhevnikov, Yu Lacourt, A Laverrière, G C Martini, M Papi, A Ponting, P J Sozzi, M Vossnack, O Wahl, H |
author_facet | Hallgren, Björn I Bal, F Barr, Giles David Buchholz, P Formenti, F Funk, W Kozhevnikov, Yu Lacourt, A Laverrière, G C Martini, M Papi, A Ponting, P J Sozzi, M Vossnack, O Wahl, H |
author_sort | Hallgren, Björn I |
collection | CERN |
description | This paper describes the issues encountered in the design of a large dynamic range digitizer for calorimetry. A gain switching technology developed for the liquid krypton calorimeter of the NA48 CP-violation experiment at CERN is described in detail. 14 bit dynamic range and better than 300 ps time resolution were achieved in beam tests with an 8 channel prototype. A mixed analog/digital ASIC has been developed. A 13,500 channel system is being produced which will be put into operation in 1996. |
id | cern-300720 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 1996 |
record_format | invenio |
spelling | cern-3007202019-09-30T06:29:59Zdoi:10.1109/NSSMIC.1995.504258doi:10.1109/23.507155http://cds.cern.ch/record/300720engHallgren, Björn IBal, FBarr, Giles DavidBuchholz, PFormenti, FFunk, WKozhevnikov, YuLacourt, ALaverrière, G CMartini, MPapi, APonting, P JSozzi, MVossnack, OWahl, HHigh rate large dynamic range analog circuitry and digitizers for fast calorimeterDetectors and Experimental TechniquesThis paper describes the issues encountered in the design of a large dynamic range digitizer for calorimetry. A gain switching technology developed for the liquid krypton calorimeter of the NA48 CP-violation experiment at CERN is described in detail. 14 bit dynamic range and better than 300 ps time resolution were achieved in beam tests with an 8 channel prototype. A mixed analog/digital ASIC has been developed. A 13,500 channel system is being produced which will be put into operation in 1996.CERN-ECP-96-004CERN-ECP-96-04CERN-ECP-96-4oai:cds.cern.ch:3007201996-02-09 |
spellingShingle | Detectors and Experimental Techniques Hallgren, Björn I Bal, F Barr, Giles David Buchholz, P Formenti, F Funk, W Kozhevnikov, Yu Lacourt, A Laverrière, G C Martini, M Papi, A Ponting, P J Sozzi, M Vossnack, O Wahl, H High rate large dynamic range analog circuitry and digitizers for fast calorimeter |
title | High rate large dynamic range analog circuitry and digitizers for fast calorimeter |
title_full | High rate large dynamic range analog circuitry and digitizers for fast calorimeter |
title_fullStr | High rate large dynamic range analog circuitry and digitizers for fast calorimeter |
title_full_unstemmed | High rate large dynamic range analog circuitry and digitizers for fast calorimeter |
title_short | High rate large dynamic range analog circuitry and digitizers for fast calorimeter |
title_sort | high rate large dynamic range analog circuitry and digitizers for fast calorimeter |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1109/NSSMIC.1995.504258 https://dx.doi.org/10.1109/23.507155 http://cds.cern.ch/record/300720 |
work_keys_str_mv | AT hallgrenbjorni highratelargedynamicrangeanalogcircuitryanddigitizersforfastcalorimeter AT balf highratelargedynamicrangeanalogcircuitryanddigitizersforfastcalorimeter AT barrgilesdavid highratelargedynamicrangeanalogcircuitryanddigitizersforfastcalorimeter AT buchholzp highratelargedynamicrangeanalogcircuitryanddigitizersforfastcalorimeter AT formentif highratelargedynamicrangeanalogcircuitryanddigitizersforfastcalorimeter AT funkw highratelargedynamicrangeanalogcircuitryanddigitizersforfastcalorimeter AT kozhevnikovyu highratelargedynamicrangeanalogcircuitryanddigitizersforfastcalorimeter AT lacourta highratelargedynamicrangeanalogcircuitryanddigitizersforfastcalorimeter AT laverrieregc highratelargedynamicrangeanalogcircuitryanddigitizersforfastcalorimeter AT martinim highratelargedynamicrangeanalogcircuitryanddigitizersforfastcalorimeter AT papia highratelargedynamicrangeanalogcircuitryanddigitizersforfastcalorimeter AT pontingpj highratelargedynamicrangeanalogcircuitryanddigitizersforfastcalorimeter AT sozzim highratelargedynamicrangeanalogcircuitryanddigitizersforfastcalorimeter AT vossnacko highratelargedynamicrangeanalogcircuitryanddigitizersforfastcalorimeter AT wahlh highratelargedynamicrangeanalogcircuitryanddigitizersforfastcalorimeter |