Cryogenic temperature measurement for large applications
We have developed a resistance thermometry system for the acquisition, control and monitoring of temperature in large-scale cryogenic applications. The resistance of the sensor is converted to a voltage using a self-balancing AC bridge circuit featuring square-wave excitation currents down to 1 nA....
Autores principales: | , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
1996
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/S0011-2275(96)00089-6 http://cds.cern.ch/record/302719 |
_version_ | 1780889615149826048 |
---|---|
author | Ylöstalo, J Berglund, P Kyynäräinen, J Niinikoski, T O Voutilainen, R |
author_facet | Ylöstalo, J Berglund, P Kyynäräinen, J Niinikoski, T O Voutilainen, R |
author_sort | Ylöstalo, J |
collection | CERN |
description | We have developed a resistance thermometry system for the acquisition, control and monitoring of temperature in large-scale cryogenic applications. The resistance of the sensor is converted to a voltage using a self-balancing AC bridge circuit featuring square-wave excitation currents down to 1 nA. The system is easily scalable and includes intelligent features to treat special situations such as magnet quenches differently from normal operation. |
id | cern-302719 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 1996 |
record_format | invenio |
spelling | cern-3027192019-09-30T06:29:59Zdoi:10.1016/S0011-2275(96)00089-6http://cds.cern.ch/record/302719engYlöstalo, JBerglund, PKyynäräinen, JNiinikoski, T OVoutilainen, RCryogenic temperature measurement for large applicationsEngineeringWe have developed a resistance thermometry system for the acquisition, control and monitoring of temperature in large-scale cryogenic applications. The resistance of the sensor is converted to a voltage using a self-balancing AC bridge circuit featuring square-wave excitation currents down to 1 nA. The system is easily scalable and includes intelligent features to treat special situations such as magnet quenches differently from normal operation.CERN-PPE-96-056oai:cds.cern.ch:3027191996-04-15 |
spellingShingle | Engineering Ylöstalo, J Berglund, P Kyynäräinen, J Niinikoski, T O Voutilainen, R Cryogenic temperature measurement for large applications |
title | Cryogenic temperature measurement for large applications |
title_full | Cryogenic temperature measurement for large applications |
title_fullStr | Cryogenic temperature measurement for large applications |
title_full_unstemmed | Cryogenic temperature measurement for large applications |
title_short | Cryogenic temperature measurement for large applications |
title_sort | cryogenic temperature measurement for large applications |
topic | Engineering |
url | https://dx.doi.org/10.1016/S0011-2275(96)00089-6 http://cds.cern.ch/record/302719 |
work_keys_str_mv | AT ylostaloj cryogenictemperaturemeasurementforlargeapplications AT berglundp cryogenictemperaturemeasurementforlargeapplications AT kyynarainenj cryogenictemperaturemeasurementforlargeapplications AT niinikoskito cryogenictemperaturemeasurementforlargeapplications AT voutilainenr cryogenictemperaturemeasurementforlargeapplications |