Study of charge collection and noise in non-irradiated and irradiated silicon detectors
The large collection and noise were studied in non-irradiated and irradiated silicon detectors as a function of temperature (T), shaping time (0) and fluence , up to about 1,2 x 10(14) protons per cm2 for minimum-ionizing electrons yielded by a 106 Ru source. The noise of irradiated detectors is fou...
Autores principales: | , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
1996
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/S0168-9002(97)00004-1 http://cds.cern.ch/record/305519 |
_version_ | 1780889771468390400 |
---|---|
author | Leroy, C Bates, S Dezillie, B Glaser, M Lemeilleur, F Trigger, I |
author_facet | Leroy, C Bates, S Dezillie, B Glaser, M Lemeilleur, F Trigger, I |
author_sort | Leroy, C |
collection | CERN |
description | The large collection and noise were studied in non-irradiated and irradiated silicon detectors as a function of temperature (T), shaping time (0) and fluence , up to about 1,2 x 10(14) protons per cm2 for minimum-ionizing electrons yielded by a 106 Ru source. The noise of irradiated detectors is found to be dominted for short shaping times (¾50ns) by a series noise compo- nent, while for longer shaping times (80ns) a parallel noise component (correlated with the reverse current) prevails. For non-irradiated detectors, where the reverse current is three orders of magnetude smaller compared with irradiated detectors, the series noises dominates over the whole range of shaping times investigated (20-150ns). A signal degradation is observed for irradiated detectors. However, the signal ca be distinguished from noise, even after a fluence of about 1.2 x10(14) protons per cm2, at a temperature of 6øC and with a shaping time tipical of rge LHC inter-bunch crossing time (20-30ns). The measurements of the signal as a function of voltage shows that irradiated detectors depleted at 50% of the full depletion voltage can still provide a measurable signal-to-noise ratio. |
id | cern-305519 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 1996 |
record_format | invenio |
spelling | cern-3055192019-09-30T06:29:59Zdoi:10.1016/S0168-9002(97)00004-1http://cds.cern.ch/record/305519engLeroy, CBates, SDezillie, BGlaser, MLemeilleur, FTrigger, IStudy of charge collection and noise in non-irradiated and irradiated silicon detectorsDetectors and Experimental TechniquesThe large collection and noise were studied in non-irradiated and irradiated silicon detectors as a function of temperature (T), shaping time (0) and fluence , up to about 1,2 x 10(14) protons per cm2 for minimum-ionizing electrons yielded by a 106 Ru source. The noise of irradiated detectors is found to be dominted for short shaping times (¾50ns) by a series noise compo- nent, while for longer shaping times (80ns) a parallel noise component (correlated with the reverse current) prevails. For non-irradiated detectors, where the reverse current is three orders of magnetude smaller compared with irradiated detectors, the series noises dominates over the whole range of shaping times investigated (20-150ns). A signal degradation is observed for irradiated detectors. However, the signal ca be distinguished from noise, even after a fluence of about 1.2 x10(14) protons per cm2, at a temperature of 6øC and with a shaping time tipical of rge LHC inter-bunch crossing time (20-30ns). The measurements of the signal as a function of voltage shows that irradiated detectors depleted at 50% of the full depletion voltage can still provide a measurable signal-to-noise ratio.CERN-ECP-96-005CERN-ECP-96-05CERN-ECP-96-5oai:cds.cern.ch:3055191996-05-30 |
spellingShingle | Detectors and Experimental Techniques Leroy, C Bates, S Dezillie, B Glaser, M Lemeilleur, F Trigger, I Study of charge collection and noise in non-irradiated and irradiated silicon detectors |
title | Study of charge collection and noise in non-irradiated and irradiated silicon detectors |
title_full | Study of charge collection and noise in non-irradiated and irradiated silicon detectors |
title_fullStr | Study of charge collection and noise in non-irradiated and irradiated silicon detectors |
title_full_unstemmed | Study of charge collection and noise in non-irradiated and irradiated silicon detectors |
title_short | Study of charge collection and noise in non-irradiated and irradiated silicon detectors |
title_sort | study of charge collection and noise in non-irradiated and irradiated silicon detectors |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1016/S0168-9002(97)00004-1 http://cds.cern.ch/record/305519 |
work_keys_str_mv | AT leroyc studyofchargecollectionandnoiseinnonirradiatedandirradiatedsilicondetectors AT batess studyofchargecollectionandnoiseinnonirradiatedandirradiatedsilicondetectors AT dezillieb studyofchargecollectionandnoiseinnonirradiatedandirradiatedsilicondetectors AT glaserm studyofchargecollectionandnoiseinnonirradiatedandirradiatedsilicondetectors AT lemeilleurf studyofchargecollectionandnoiseinnonirradiatedandirradiatedsilicondetectors AT triggeri studyofchargecollectionandnoiseinnonirradiatedandirradiatedsilicondetectors |