DC measurement of electrical contacts between strands in superconducting cables for the LHC main magnets

In the LHC main magnets, using Rutherford type cable, the eddy current loss and dynamic magnetic field error depend largely on the electrical resistance between crossing (Rc) and adjacent (Ra) strands. Cables made of strands with pre-selected coatings have been studied at low temperature using a DC...

Descripción completa

Detalles Bibliográficos
Autores principales: Richter, D, Adam, J D, Depond, J M, Leroy, D, Oberli, L R
Lenguaje:eng
Publicado: 1996
Materias:
Acceso en línea:https://dx.doi.org/10.1109/77.614621
http://cds.cern.ch/record/314898
_version_ 1780890314713595904
author Richter, D
Adam, J D
Depond, J M
Leroy, D
Oberli, L R
author_facet Richter, D
Adam, J D
Depond, J M
Leroy, D
Oberli, L R
author_sort Richter, D
collection CERN
description In the LHC main magnets, using Rutherford type cable, the eddy current loss and dynamic magnetic field error depend largely on the electrical resistance between crossing (Rc) and adjacent (Ra) strands. Cables made of strands with pre-selected coatings have been studied at low temperature using a DC electrical method. The significance of the inter-strand contact is explained. The properties of resistive barriers, the DC method used for the resistance measurement on the cable, and sample preparation are described. Finally the resistances are presented under various conditions, and the effect is discussed that the cable treatment has on the contact resistance.
id cern-314898
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 1996
record_format invenio
spelling cern-3148982023-05-31T13:22:57Zdoi:10.1109/77.614621http://cds.cern.ch/record/314898engRichter, DAdam, J DDepond, J MLeroy, DOberli, L RDC measurement of electrical contacts between strands in superconducting cables for the LHC main magnetsAccelerators and Storage RingsIn the LHC main magnets, using Rutherford type cable, the eddy current loss and dynamic magnetic field error depend largely on the electrical resistance between crossing (Rc) and adjacent (Ra) strands. Cables made of strands with pre-selected coatings have been studied at low temperature using a DC electrical method. The significance of the inter-strand contact is explained. The properties of resistive barriers, the DC method used for the resistance measurement on the cable, and sample preparation are described. Finally the resistances are presented under various conditions, and the effect is discussed that the cable treatment has on the contact resistance.LHC-Project-Report-67CERN-LHC-Project-Report-67oai:cds.cern.ch:3148981996-10-25
spellingShingle Accelerators and Storage Rings
Richter, D
Adam, J D
Depond, J M
Leroy, D
Oberli, L R
DC measurement of electrical contacts between strands in superconducting cables for the LHC main magnets
title DC measurement of electrical contacts between strands in superconducting cables for the LHC main magnets
title_full DC measurement of electrical contacts between strands in superconducting cables for the LHC main magnets
title_fullStr DC measurement of electrical contacts between strands in superconducting cables for the LHC main magnets
title_full_unstemmed DC measurement of electrical contacts between strands in superconducting cables for the LHC main magnets
title_short DC measurement of electrical contacts between strands in superconducting cables for the LHC main magnets
title_sort dc measurement of electrical contacts between strands in superconducting cables for the lhc main magnets
topic Accelerators and Storage Rings
url https://dx.doi.org/10.1109/77.614621
http://cds.cern.ch/record/314898
work_keys_str_mv AT richterd dcmeasurementofelectricalcontactsbetweenstrandsinsuperconductingcablesforthelhcmainmagnets
AT adamjd dcmeasurementofelectricalcontactsbetweenstrandsinsuperconductingcablesforthelhcmainmagnets
AT depondjm dcmeasurementofelectricalcontactsbetweenstrandsinsuperconductingcablesforthelhcmainmagnets
AT leroyd dcmeasurementofelectricalcontactsbetweenstrandsinsuperconductingcablesforthelhcmainmagnets
AT oberlilr dcmeasurementofelectricalcontactsbetweenstrandsinsuperconductingcablesforthelhcmainmagnets