Cargando…
DC measurement of electrical contacts between strands in superconducting cables for the LHC main magnets
In the LHC main magnets, using Rutherford type cable, the eddy current loss and dynamic magnetic field error depend largely on the electrical resistance between crossing (Rc) and adjacent (Ra) strands. Cables made of strands with pre-selected coatings have been studied at low temperature using a DC...
Autores principales: | Richter, D, Adam, J D, Depond, J M, Leroy, D, Oberli, L R |
---|---|
Lenguaje: | eng |
Publicado: |
1996
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1109/77.614621 http://cds.cern.ch/record/314898 |
Ejemplares similares
-
Strand Coating for the Superconducting Cables of the LHC Main Magnets
por: Adam, J D, et al.
Publicado: (1998) -
Superconducting cable topology
por: Depond, J, et al.
Publicado: (1997) -
Examination of contacts between strands by electrical measurements and topographical analysis
por: Depond, J M, et al.
Publicado: (1996) -
The quality assurance of superconducting strand and cable for LHC
por: Oberli, L R
Publicado: (2001) -
Critical Current Test Facilities for LHC Superconducting NbTi Cable Strands
por: Boutboul, T, et al.
Publicado: (2001)