Cargando…
Examination of contacts between strands by electrical measurements and topographical analysis
The contact resistance (crossing and adjacent) between the strands of Rutherford type superconducting cables has been proven to be an essential parameter for the behaviour of the main magnets in accelerators like the LHC. A strong development program has been launched at CERN. Contact resistances we...
Autores principales: | , , , |
---|---|
Lenguaje: | eng |
Publicado: |
1996
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1109/77.614622 http://cds.cern.ch/record/315079 |
_version_ | 1780890324113031168 |
---|---|
author | Depond, J M Leroy, D Oberli, L R Richter, D |
author_facet | Depond, J M Leroy, D Oberli, L R Richter, D |
author_sort | Depond, J M |
collection | CERN |
description | The contact resistance (crossing and adjacent) between the strands of Rutherford type superconducting cables has been proven to be an essential parameter for the behaviour of the main magnets in accelerators like the LHC. A strong development program has been launched at CERN. Contact resistances were measured by means of a DC method at 4.2 K. The strand deformation and the chemical conditions at the contacts were analyzed in order to interpret the electrical resistances measured by a 3 contacts method on individual strands as well as the resistances measured independently on cables. |
id | cern-315079 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 1996 |
record_format | invenio |
spelling | cern-3150792023-05-31T13:24:07Zdoi:10.1109/77.614622http://cds.cern.ch/record/315079engDepond, J MLeroy, DOberli, L RRichter, DExamination of contacts between strands by electrical measurements and topographical analysisAccelerators and Storage RingsThe contact resistance (crossing and adjacent) between the strands of Rutherford type superconducting cables has been proven to be an essential parameter for the behaviour of the main magnets in accelerators like the LHC. A strong development program has been launched at CERN. Contact resistances were measured by means of a DC method at 4.2 K. The strand deformation and the chemical conditions at the contacts were analyzed in order to interpret the electrical resistances measured by a 3 contacts method on individual strands as well as the resistances measured independently on cables.LHC-Project-Report-72CERN-LHC-Project-Report-72oai:cds.cern.ch:3150791996-10-30 |
spellingShingle | Accelerators and Storage Rings Depond, J M Leroy, D Oberli, L R Richter, D Examination of contacts between strands by electrical measurements and topographical analysis |
title | Examination of contacts between strands by electrical measurements and topographical analysis |
title_full | Examination of contacts between strands by electrical measurements and topographical analysis |
title_fullStr | Examination of contacts between strands by electrical measurements and topographical analysis |
title_full_unstemmed | Examination of contacts between strands by electrical measurements and topographical analysis |
title_short | Examination of contacts between strands by electrical measurements and topographical analysis |
title_sort | examination of contacts between strands by electrical measurements and topographical analysis |
topic | Accelerators and Storage Rings |
url | https://dx.doi.org/10.1109/77.614622 http://cds.cern.ch/record/315079 |
work_keys_str_mv | AT depondjm examinationofcontactsbetweenstrandsbyelectricalmeasurementsandtopographicalanalysis AT leroyd examinationofcontactsbetweenstrandsbyelectricalmeasurementsandtopographicalanalysis AT oberlilr examinationofcontactsbetweenstrandsbyelectricalmeasurementsandtopographicalanalysis AT richterd examinationofcontactsbetweenstrandsbyelectricalmeasurementsandtopographicalanalysis |