Cargando…

Luminosity and beta function measurement at the electron-positron collider ring LEP

The optimization of luminosity needs a fast signal which is provided with the measurement of the rate of small angle Bhabba scattered e+ and e-. It is shown that, despite the excess of background particles received at the detectors, luminosity measurements are possible by using appropriate technique...

Descripción completa

Detalles Bibliográficos
Autor principal: Castro, P
Lenguaje:eng
Publicado: CERN 1996
Materias:
Acceso en línea:http://cds.cern.ch/record/316609
_version_ 1780890398686707712
author Castro, P
author_facet Castro, P
author_sort Castro, P
collection CERN
description The optimization of luminosity needs a fast signal which is provided with the measurement of the rate of small angle Bhabba scattered e+ and e-. It is shown that, despite the excess of background particles received at the detectors, luminosity measurements are possible by using appropriate techniques. The results presented include examples of luminosity optimization with the adjustment of the vertical beam separation at interaction points. The correlation between changes in measured beam sizes and changes in luminosity is shown. In the second part, a new method to obtain precise optics measurements is presented. The procedure to measure the phase advance using 1000-turn orbit measurements of a horizontally or vertically excited beam is described. Beta, alpha and phase advance functions can be obtained exclusively from the phase advances at beam position monitors. This method has been used to measure optics imperfections at LEP. Results of these experiments are compared with simulation results using MAD Measurements of chromaticity and impedance distributions are also reported.
id cern-316609
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 1996
publisher CERN
record_format invenio
spelling cern-3166092023-05-05T12:57:29Zhttp://cds.cern.ch/record/316609engCastro, PLuminosity and beta function measurement at the electron-positron collider ring LEPAccelerators and Storage RingsThe optimization of luminosity needs a fast signal which is provided with the measurement of the rate of small angle Bhabba scattered e+ and e-. It is shown that, despite the excess of background particles received at the detectors, luminosity measurements are possible by using appropriate techniques. The results presented include examples of luminosity optimization with the adjustment of the vertical beam separation at interaction points. The correlation between changes in measured beam sizes and changes in luminosity is shown. In the second part, a new method to obtain precise optics measurements is presented. The procedure to measure the phase advance using 1000-turn orbit measurements of a horizontally or vertically excited beam is described. Beta, alpha and phase advance functions can be obtained exclusively from the phase advances at beam position monitors. This method has been used to measure optics imperfections at LEP. Results of these experiments are compared with simulation results using MAD Measurements of chromaticity and impedance distributions are also reported.CERNCERN-SL-96-070-BIoai:cds.cern.ch:3166091996
spellingShingle Accelerators and Storage Rings
Castro, P
Luminosity and beta function measurement at the electron-positron collider ring LEP
title Luminosity and beta function measurement at the electron-positron collider ring LEP
title_full Luminosity and beta function measurement at the electron-positron collider ring LEP
title_fullStr Luminosity and beta function measurement at the electron-positron collider ring LEP
title_full_unstemmed Luminosity and beta function measurement at the electron-positron collider ring LEP
title_short Luminosity and beta function measurement at the electron-positron collider ring LEP
title_sort luminosity and beta function measurement at the electron-positron collider ring lep
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/316609
work_keys_str_mv AT castrop luminosityandbetafunctionmeasurementattheelectronpositroncolliderringlep