Cargando…
Design and Test of a Forward Neutron Calorimeter for the ZEUS Experiment
A lead scintillator sandwich sampling calorimeter has been installed in the HERA tunnel 105.6 m from the central ZEUS detector in the proton beam direction. It is designed to measure the energy and scattering angle of neutrons produced in charge exchange ep collisions. Before installation the calori...
Autores principales: | , , , , , , , , , , , , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
1997
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/S0168-9002(97)00647-5 http://cds.cern.ch/record/319086 |
_version_ | 1780890540734152704 |
---|---|
author | Bhadra, S. Bohnet, I. Cardy, M. Dosselli, U. Fagerstroem, C.-P. Frisken, W. Furutani, K. Hanna, D. Holm, U. Johnson, K.F. Khakzad, M. Levman, G. Lim, J.N. Loehr, B. Martin, J.F. Muhl, C. Neumann, T. Rohde, M. Schmidke, W.B. Stairs, D.G. Tiecke, H. Voci, C. |
author_facet | Bhadra, S. Bohnet, I. Cardy, M. Dosselli, U. Fagerstroem, C.-P. Frisken, W. Furutani, K. Hanna, D. Holm, U. Johnson, K.F. Khakzad, M. Levman, G. Lim, J.N. Loehr, B. Martin, J.F. Muhl, C. Neumann, T. Rohde, M. Schmidke, W.B. Stairs, D.G. Tiecke, H. Voci, C. |
author_sort | Bhadra, S. |
collection | CERN |
description | A lead scintillator sandwich sampling calorimeter has been installed in the HERA tunnel 105.6 m from the central ZEUS detector in the proton beam direction. It is designed to measure the energy and scattering angle of neutrons produced in charge exchange ep collisions. Before installation the calorimeter was tested and calibrated in the H6 beam at CERN where 120 GeV electrons, muons, pions and protons were made incident on the calorimeter. In addition, the spectrum of fast neutrons from charge exchange proton-lucite collisions was measured. The design and construction of the calorimeter is described, and the results of the CERN test reported. Special attention is paid to the measurement of shower position, shower width, and the separation of electromagnetic showers from hadronic showers. The overall energy scale as determined from the energy spectrum of charge exchange neutrons is compared to that obtained from direct beam hadrons. |
id | cern-319086 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 1997 |
record_format | invenio |
spelling | cern-3190862019-09-30T06:29:59Zdoi:10.1016/S0168-9002(97)00647-5http://cds.cern.ch/record/319086engBhadra, S.Bohnet, I.Cardy, M.Dosselli, U.Fagerstroem, C.-P.Frisken, W.Furutani, K.Hanna, D.Holm, U.Johnson, K.F.Khakzad, M.Levman, G.Lim, J.N.Loehr, B.Martin, J.F.Muhl, C.Neumann, T.Rohde, M.Schmidke, W.B.Stairs, D.G.Tiecke, H.Voci, C.Design and Test of a Forward Neutron Calorimeter for the ZEUS ExperimentDetectors and Experimental TechniquesA lead scintillator sandwich sampling calorimeter has been installed in the HERA tunnel 105.6 m from the central ZEUS detector in the proton beam direction. It is designed to measure the energy and scattering angle of neutrons produced in charge exchange ep collisions. Before installation the calorimeter was tested and calibrated in the H6 beam at CERN where 120 GeV electrons, muons, pions and protons were made incident on the calorimeter. In addition, the spectrum of fast neutrons from charge exchange proton-lucite collisions was measured. The design and construction of the calorimeter is described, and the results of the CERN test reported. Special attention is paid to the measurement of shower position, shower width, and the separation of electromagnetic showers from hadronic showers. The overall energy scale as determined from the energy spectrum of charge exchange neutrons is compared to that obtained from direct beam hadrons.hep-ex/9701015DESY-97-006DESY-97-006oai:cds.cern.ch:3190861997-01-27 |
spellingShingle | Detectors and Experimental Techniques Bhadra, S. Bohnet, I. Cardy, M. Dosselli, U. Fagerstroem, C.-P. Frisken, W. Furutani, K. Hanna, D. Holm, U. Johnson, K.F. Khakzad, M. Levman, G. Lim, J.N. Loehr, B. Martin, J.F. Muhl, C. Neumann, T. Rohde, M. Schmidke, W.B. Stairs, D.G. Tiecke, H. Voci, C. Design and Test of a Forward Neutron Calorimeter for the ZEUS Experiment |
title | Design and Test of a Forward Neutron Calorimeter for the ZEUS Experiment |
title_full | Design and Test of a Forward Neutron Calorimeter for the ZEUS Experiment |
title_fullStr | Design and Test of a Forward Neutron Calorimeter for the ZEUS Experiment |
title_full_unstemmed | Design and Test of a Forward Neutron Calorimeter for the ZEUS Experiment |
title_short | Design and Test of a Forward Neutron Calorimeter for the ZEUS Experiment |
title_sort | design and test of a forward neutron calorimeter for the zeus experiment |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1016/S0168-9002(97)00647-5 http://cds.cern.ch/record/319086 |
work_keys_str_mv | AT bhadras designandtestofaforwardneutroncalorimeterforthezeusexperiment AT bohneti designandtestofaforwardneutroncalorimeterforthezeusexperiment AT cardym designandtestofaforwardneutroncalorimeterforthezeusexperiment AT dosselliu designandtestofaforwardneutroncalorimeterforthezeusexperiment AT fagerstroemcp designandtestofaforwardneutroncalorimeterforthezeusexperiment AT friskenw designandtestofaforwardneutroncalorimeterforthezeusexperiment AT furutanik designandtestofaforwardneutroncalorimeterforthezeusexperiment AT hannad designandtestofaforwardneutroncalorimeterforthezeusexperiment AT holmu designandtestofaforwardneutroncalorimeterforthezeusexperiment AT johnsonkf designandtestofaforwardneutroncalorimeterforthezeusexperiment AT khakzadm designandtestofaforwardneutroncalorimeterforthezeusexperiment AT levmang designandtestofaforwardneutroncalorimeterforthezeusexperiment AT limjn designandtestofaforwardneutroncalorimeterforthezeusexperiment AT loehrb designandtestofaforwardneutroncalorimeterforthezeusexperiment AT martinjf designandtestofaforwardneutroncalorimeterforthezeusexperiment AT muhlc designandtestofaforwardneutroncalorimeterforthezeusexperiment AT neumannt designandtestofaforwardneutroncalorimeterforthezeusexperiment AT rohdem designandtestofaforwardneutroncalorimeterforthezeusexperiment AT schmidkewb designandtestofaforwardneutroncalorimeterforthezeusexperiment AT stairsdg designandtestofaforwardneutroncalorimeterforthezeusexperiment AT tieckeh designandtestofaforwardneutroncalorimeterforthezeusexperiment AT vocic designandtestofaforwardneutroncalorimeterforthezeusexperiment |