Cargando…
Pre-Alignment of CLIC using the Double-Wire Method
The pre-alignment and active control method for the Compact Linear Collider (CLIC) is described. Two new types of instruments are used in this system - a biaxial Wire Positioning System (WPS) which uses a stretched wire as the spatial reference, and a capacitive three axes Tilt Meter System (TMS). T...
Autores principales: | , |
---|---|
Lenguaje: | eng |
Publicado: |
1997
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/327017 |
_version_ | 1780890969641582592 |
---|---|
author | Coosemans, Williame Mainaud, H |
author_facet | Coosemans, Williame Mainaud, H |
author_sort | Coosemans, Williame |
collection | CERN |
description | The pre-alignment and active control method for the Compact Linear Collider (CLIC) is described. Two new types of instruments are used in this system - a biaxial Wire Positioning System (WPS) which uses a stretched wire as the spatial reference, and a capacitive three axes Tilt Meter System (TMS). The instruments, and the way they are used with the well-known Hydrostatic Levelling System (HLS) are described. |
id | cern-327017 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 1997 |
record_format | invenio |
spelling | cern-3270172023-07-20T15:01:19Zhttp://cds.cern.ch/record/327017engCoosemans, WilliameMainaud, HPre-Alignment of CLIC using the Double-Wire MethodAccelerators and Storage RingsThe pre-alignment and active control method for the Compact Linear Collider (CLIC) is described. Two new types of instruments are used in this system - a biaxial Wire Positioning System (WPS) which uses a stretched wire as the spatial reference, and a capacitive three axes Tilt Meter System (TMS). The instruments, and the way they are used with the well-known Hydrostatic Levelling System (HLS) are described.CERN-PS-97-028-LPCLIC-Note-343oai:cds.cern.ch:3270171997-05-22 |
spellingShingle | Accelerators and Storage Rings Coosemans, Williame Mainaud, H Pre-Alignment of CLIC using the Double-Wire Method |
title | Pre-Alignment of CLIC using the Double-Wire Method |
title_full | Pre-Alignment of CLIC using the Double-Wire Method |
title_fullStr | Pre-Alignment of CLIC using the Double-Wire Method |
title_full_unstemmed | Pre-Alignment of CLIC using the Double-Wire Method |
title_short | Pre-Alignment of CLIC using the Double-Wire Method |
title_sort | pre-alignment of clic using the double-wire method |
topic | Accelerators and Storage Rings |
url | http://cds.cern.ch/record/327017 |
work_keys_str_mv | AT coosemanswilliame prealignmentofclicusingthedoublewiremethod AT mainaudh prealignmentofclicusingthedoublewiremethod |