Cargando…

Trajectory measurement of bunches ejected from the CERN PSB

The transfer line of the PS Booster(PSB) recombines beams from the 4 vertically stacked rings of the PSB and sends them to 1 of 3 possible destinations: the 26 GeV PS, ISOLDE, or the measurement line. To acquire the transverse positions of the beam, 18 electrostatic pick-ups are distributed along th...

Descripción completa

Detalles Bibliográficos
Autores principales: Le Gras, M, Williams, D J
Lenguaje:eng
Publicado: 1997
Materias:
Acceso en línea:http://cds.cern.ch/record/341102
Descripción
Sumario:The transfer line of the PS Booster(PSB) recombines beams from the 4 vertically stacked rings of the PSB and sends them to 1 of 3 possible destinations: the 26 GeV PS, ISOLDE, or the measurement line. To acquire the transverse positions of the beam, 18 electrostatic pick-ups are distributed along the lines and variable gain triple-channel amplifiers (DH, DV and S), equipped with a calibration system that operates every cycle, are mounted on each pick-up. The digitisation is achieved with 8-bit 250MHz ADC VME modules. Data treatment allows simultaneous calculations of the beam position corresponding to each ring to be made for all pick-ups on every cycle as well as allowing calibration, base-line correction and auto-ranging for optimising the resolution of the fast ADCs. Measurements are made with a resolution of 0.3 mm (full scale 33 mm) over an intensity range of 100 for a maximum of 1013 protons per ring. The data treatment is performed as a real-time task in a VME crate equipped with a Motorola MVME147 CPU board and conforms to the standard instrumentation protocol as well as the PS control system.