Cargando…
A Comparative Study of Fast Wire Scanners, Beamscope and SEM-Grids for Emittance Measurements in the PS Booster
The tight emittance budget, imposed on the production of the high-brilliance beams in the LHC preinjectors, demands the elimination of all possible sources of beam blow-up. A prerequisite for this is reliable instrumentation and evaluation methods for comparison of their data. We have made a study o...
Autores principales: | , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
1997
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/341104 |
Sumario: | The tight emittance budget, imposed on the production of the high-brilliance beams in the LHC preinjectors, demands the elimination of all possible sources of beam blow-up. A prerequisite for this is reliable instrumentation and evaluation methods for comparison of their data. We have made a study of three methods for emittance measurement in the PS Booster: fast wire-scanners, BeamScope, and SEM-grids in a measurement line. For the fast wire-scanners, a full Monte-Carlo simulation was made of the beam-wire interaction, for an energy range from 100 MeV to 1 GeV, and compared to measured values. Data from a scraping method (BeamScope) are compared to profile measurements, using Abel-type integral transformations. Results will be presented. |
---|